Bids Are Invited For Custom Bid For Services - Repair Rate Contract For Routine/ Repair Of Stp System Onboard In Ships For A Period Of One Year And Extendable For Two More Years At Nd (Kar) - Overhaul Of Macerator Pump Iaw Oem Manual , Renewal Of Macerator Pump , Overhaul Of Macerator Pump Motor Iaw Oem Manual , Renewal Of Macerator Pump Motor , Overhaul Filling Pump As Per Oem Manual , Renewal Of Filling Pump , Overhaul Of Filling Pump Motor As Per Oem Manual , Renewal Of Filling Pump Motor , Overhaul Of Obd Pump As Per Oem Manual , Renewal Of Obd Pump , Overhaul Of Obd Pump Motor As Per Oem Manual , Renewal Of Obd Pump Motor , Repair Of Obd Pump Starter , Renewal Of Obd Pump Starter , Overhaul Of Imo Pump As Per Oem Manual , Renewal Of Imo Pump , Overhaul Of Imo Pump Motor As Per Oem Manual , Renewal Of Imo Pump Motor , Repair Of Imo Pump Starter , Renewal Of Imo Pump Starter , Overhaul/ Repair Of Three Way Valve As Per Oem Manual , Renewal Of Three Way Valve , Overhaul/ Repair Of Dosing Pump , Renewal Of Dosing Pump , Renewal Of Dosing Line , Filling Up Of Disinfectant Fluid (H202 Solution) , Renewal Of Rubber Compensator Fitted Between Lines Per Plant , Serviceability Checks Of Solenoid Valve For Sea Water Supply , Renewal Of Solenoid Valve For Sea Water Supply , Serviceability Checks For Sensors For Filling Water Pump , Renewal Of Sensor For Filling Water Pump , Serviceability Checks / Repair Of Float Switches Fitted In Collection Tank , Renewal Of Float Switches Fitted In Collection Tank , Serviceability Checks/ Repair Of Float Switches Fitted In Treatment Tank , Renewal Of Float Switches Fitted In Treatment Tank , Inspection, Pressure Testing/ Leak Testing Per System Pipelines Including Overload Discharge Lines, Flushing Lines, Imo Lines, Lower End Vent Line, Tank Vent Line, Tank Vent Lines, Gas Indicator Lines And Pvc Line Per Meter. , Repair/ Renewal Of Pipeline Including Overboard Discharge Lines, Flushing Lines, Imo Lines, Lower End Vent Line, Tank Vent Lines, Gas Indicator Lines And Pvc Line Per Meter , Repair/ Reconditioning Of Blower With Motor , Serviceability Checks/ Repair Of Pressure Sensor Fitted In Collection Tank For Remote Indication Of Level In Dchq , Serviceability Checks Of Electrical Equipment / Sensors Fitted In Tanks (Viz Over Pressure Sensor Etc) , Renewal Of Electrical Equipment/ Sensors Fitted In Tanks (Viz Over Pressure Sensor Etc) , Renewal Of Pressure Sensor For Remote Indication Of Tank Level In Dciq , Overhauling / Functionality Checks Of Of Electrical Control Panel (Plc Based) And Repair Any Defect On Electrical Control Panel , Renewal Of Electric Component Of Electric Control Panel , Repair/ Renewal Of Electrical Cable And Accessories Including Earthing , Inspection And Calibration Of Instrumentation Per Plant , Renewal Of Pressure Gauges For Obs Pumps , Endurance Test And Effluent Test Of S Les Of Stp For Bod And Tss On Completion Of Major Repairs As Proposed By Ss/ Every Six , Renewal Of Various Tallies Per Plant , Impeller For Macerating / Transfer Pump S8 1 , Mechanical Seal For Macerating / Transfer Pump S8 1 , Wear Plate For S81 , Maintenance Kit For Dosing Pump , 2-Way Valve 1 24V Ac Gas F Solen , Pressure Regulator , Actuator For 3-Way Valve 2 , Floating Level Sensor Mobrey , Level Probe Inox 316L, Side Mounting , Ecomar Cover Board Pro14 R3 For Ecomar , Actuator For Rotary Valve Ea0130 , Flanged Rubber Joint Dn25 , Flanged Rubber Joint Dn50 , Flanged Rubber Joint Dn65 , Flanged Rubber Joint Dn80 , Pcb Board Pro14/02 , Exp14/0A Rev. 1 Board For Ecomar , Transformer 100Va Prim: 230/400/415-Sec: 12/24V , Transf. 400Va Prim: 380-400-415-440V Sec.230V , Fuse 2A (5X20) , Fuse 2A (10X38) , Fuse 1A (10X38) , Motor Circuit Breaker 2.5-4A , Motor Circuit Breaker 9-14A , Led 24V Ac/Dc , Contactor Lc1D18B7 18A 24Vac 50/6 , Contattore Lc1D09B7 9A 24Vac 50/6 , Contactor For Ecomar 4P 24V 50/60Hz , Relay 24Vac 40.52.8.024 , Flat Cable 20 Poles , Auxiliary Contactor Ladn20 , Measure And Control Relay 208-480Vac , Switching Power Input 24Vac Output 12/24Vdc
|