Bids Are invited for Mandl For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Area 10 Sqmm 4 Core - Mandl For Cable In Trenches Or Passing Through Pipe, Xlpe Insulated, Heavy Duty, Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 10 Sqmm 4 Core Including Cable Gland And Lugs Including Taking Down Old Unserviceable Cable Complete All As Specified And Directed. , All As Per Item Ser No. 1 Above But Of Size 16 Sqmm 4 Core. , All As Per Item Ser No. 1 Above But Of Size 25 Sqmm 3.5 Core. , All As Per Item Ser No. 1 Above But Of Size 50 Sqmm 3.5 Core. , All As Per Item Ser No. 1 Above But Of Size 70 Sqmm 3.5 Core. , All As Per Item Ser No. 1 Above But Of Size 95 Sqmm 3.5 Core. , All As Per Item Ser No. 1 Above But Of Size 120 Sqmm 3.5 Core. , Excavating In Trenches Not Exc. 1.50 Mtr Wide And Not Exc. 1.50 Mtr - Excavating In Trenches Not Exc. 1.50 Mtr Wide And Not Exc. 1.50 Mtr In Depth, Getting Out In Soft / Loose Soil, Complete All As Specified And As Directed. , Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exc. 250Mm - Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc. 250Mm In Soft/Loose Soil, Complete All As Specified And As Directed. , Removing Excavated Materials Soils Not Exc. 50.00 Mtr And Depositing Where Directed At A Level Not Exc. 1.50 Mtr - Removing Excavated Materials Soils Not Exc. 50.00 Mtr And Depositing Where Directed At A Level Not Exc. 1.50 Mtr Above The Starting Point In Soil, Complete All As Specified And As Directed. , M And L Sand Cushioning Dry In Trenches For Protection Of Ug Cables Below Above And Around The Ug Cable Laid In Trenches Of 230Mm - Mandl Sand Cushioning Dry In Trenches For Protection Of Ug Cables Below, Above And Around The Ug Cable Laid In Trenches Of 230Mm Spread Thickness And Consolidated Punned Upto 180Mm Thickness, Complete All As Specified And As Directed. Note For The Purpose Of Payment, Punned Thickness Of Sand Cushioning Only Shall Be Measured And Paid . , M And L For Fly Ash Bricks Locally Available Laid Dry Width Wise Across The Line Of Cable - Mandl For Fly Ash Bricks Locally Available Laid Dry Width Wise Across The Line Of Cable In Trenches For Protection Of Ug Cable, Complete All As Specified And As Directed. , S And F Galvanised Iron Pipe 80Mm Bore Dia Light Grade For Protection Of Ug Cable - Sandf Galvanised Iron Pipe 80Mm Bore Dia Light Grade For Protection Of Ug Cable, Laid In Floors/ Road Crossing, Fixing To Pole With Mild Steel Cl S, Nuts, Bolts, Etc., Complete All As Specified And As Directed. , S And F Galvanised Iron Pipe 50Mm Bore Dia Light Grade For Protection Of Ug Cable - Sandf Galvanised Iron Pipe 50Mm Bore Dia Light Grade For Protection Of Ug Cable, Laid In Floors/ Road Crossing, Fixing To Pole With Mild Steel Cl S, Nuts, Bolts, Etc., Complete All As Specified And As Directed. , S And F Hdpe Dwc Double Walled Corrugated Of Diameter 40 Mm Including Disconnection And Connection - S And F Hdpe Dwc Double Walled Corrugated Of Diameter 40 Mm Including Disconnection And Connection Of Cable Near Panel/Oh For Pipe Fixing Including Joints Complete All As Directed. , S And F Hdpe Dwc Double Walled Corrugated Of Diameter 63 Mm Including Disconnection And Connection Of Cable - S And F Hdpe Dwc Double Walled Corrugated Of Diameter 63 Mm Including Disconnection And Connection Of Cable Near Panel/Oh For Pipe Fixing Including Joints Complete All As Directed. , M And L For Horizontal Boring For Passing Protection Pipe Up To 80Mm Bore Dia Under Road Foot Path Not Exc. 10.00 Mtr - Mandl For Horizontal Boring For Passing Protection Pipe Up To 80Mm Bore Dia , Under Road /Foot Path, Not Exc. 10.00 Mtr In A Single Length, Complete All As Specified And As Directed. Note Pipe To Be Measured Separately. , Mandl For Earthing Complete With Ms Galvanized Plate Of Size 60Cmx60cmx6mm As Earth Electrode Buried Directly In Ground - Mandl For Earthing Complete With Ms Galvanized Plate Of Size 60Cmx60cmx6mm As Earth Electrode , Buried Directly In Ground Earth Pit Not Less Than 2.25 Mtrs Deep Below Ground Level With Top Edge Of The Plate Not Less Than 1.5 Mtrs Below Normal Ground Level, Connected To Galvanised Iron Strip 25X4mm As Earthing Lead By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron/Welding Or Steel All As Shown In Electrical Plate No 3 In Ssr Part I Of 2009 Connected To Earthing Test Point All As Specified Complete With Excavation And Earth Work, Pcc Pit With 50Mm Thick Rcc Cover/Ci /Ms Cover Having Suitable Handle 10Mm Ms Rod 20Mm Dia Gi Medium Grade Watering Pipe With Gi Funnel With Wire Mesh 40Mm Bore Gi Pipe Medium Grade Isi Marked For Protection Of Earth Lead Conductor And Testing On Completion Complete All As Specified And As Directed By Engineer-In-Charge.
|