|
Triplecontrol (Aso/Crp/Rf) L: 3×1 Ml+H: 3×1 Ml. Triplecontrol L: 3X1 Ml; H: 3X1 Ml (Aso/Crp/Rf) From The Mindray Bs-240Pro Biochemical Analyzer Kit, Glycolyzed Hemoglobin With Calibrator And Control R(Hb: 1X30 Ml, R1 (Hba1c: 1X30 Ml, R2(Hba1c: 1X12 Ml + Calibrator 2X1 Ml + Quality Control 2X1 Ml Pretreatment Solution 1X150 Ml. Lyophilisate For Preparing 1 Ml Of Control Serum With A Known Pathological Content Of Glycosylated Hemoglobin, From Kit Biochemical Analyzer Mindray Bs-240Pro Closed Type Without Arbitrary Methods 4 Bottles. The Kit Must Be Marked With A Special Bar Code Compatible With A Reader For A Closed System., Lipase Kit (Enzymatic Colorimetric Analysis Method) (R1:1*35 Ml+R2:1*9 Ml. Lipase With Calibrator And Control R1:1X35ml +R2 1X9ml+ Calibrator:1X3ml+ Quality Control 1X5ml, Ferritin (Fer) R1: 1×12 Ml + R2: 1×7 Ml. Two-Component Set Of Reagents For Determining Fer (Ferritin) From The Mindray Bs-240Pro Closed-Type Biochemical Analyzer Without Arbitrary Methods. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted To The Reagent Carousel Of The Analyzer. Containers Must Be Equipped With A Special Barcode Compatible With The Built-In Scanner Of The Analyzer. R1:1*12 Ml+R2:1*7 Ml, Antistreptolysin O Ii With Calibrator R1:1×23 Ml+R2:1×23 Ml+Calibrator:1×0.5 Ml. Two-Component Set Of Reagents For The Determination Of Antistreptolysin-O With A Calibrator From The Kit With A Closed-Type Biochemical Analyzer Mindray Bs-240Pro Without Arbitrary Methods. The Volume Of The Working Solution Is At Least 80 Ml. Reagents Must Be Packaged In Disposable Original Containers R1-40Ml And R2-40Ml To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges, Calibrator 1 Vial. Not Less Than 0.5 Ml. The Container Must Be Fully Adapted To The Reagent Carousel Of The Analyzer. Containers Must Be Equipped With A Special Barcode Compatible With The Built-In Scanner Of The Analyzer., Rheumatoid Factor Ii With Calibrator R1: 1X40 Ml + R2: 1X11 Ml + Calibrator 5X0.5 Ml. Two-Component Set Of Reagents For Determining Rheumatoid Factor With A Calibrator From The Kit With A Closed-Type Biochemical Analyzer Mindray Bs-240Pro Without Arbitrary Methods. The Volume Of The Working Solution Is At Least 51 Ml. Reagents Must Be Packaged In Disposable Original Containers R1-40Ml And R2-11Ml To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges, Calibrator 5 Fl. At Least 0.5 Ml For Five-Point Calibration. The Containers Must Be Fully Adapted To The Reagent Carousel Of The Analyzer. Containers Must Be Equipped With A Special Barcode Compatible With The Built-In Scanner Of The Analyzer., Calibrator Fer (Ferritin) 1*4 Levels X2. Calibrator Fer (Ferritin) 1X4 Levels X2 From The Kit, The Closed-Type Biochemical Analyzer Mindray Bs-240Pro Without Arbitrary Methods Must Be Equipped With A Special Barcode Compatible With The Built-In Scanner Of The Analyzer., Creatine Kinase Mb (Ck-Mb) R1: 2×35 Ml + R2: 1×18 Ml. Creatine Kinase Activity Is Measured In The Presence Of An Antibody To The Creatine Kinase-M Monomer, Which Completely Inhibits Creatine Kinase-Mm, But Does Not Affect The Activity Of Monomer B Creatine Kinase-Mb Or Creatine Kinase-Bb. Since Creatine Kinase-Mb Consists Of Equal Subunits M And B, Its Measured Activity Is 50 Percent Of That Found In The Absence Antibodies. Creatine Kinase-B Monomer Activity Is Then Determined As Follows: Reactions, Immunoglobulin G (Igg) R1: 1 X 36 Ml + R2: 1 X 18 Ml. This Test Is Based On Immunotransmission Turbidimetry And Is Used To Quantify The Content Of Immunoglobulin G In Human Serum In Vitro. It Has An Important Reference Value For Diagnosis, Monitoring Of Disease Changes And Treatment Effectiveness Of Relevant Clinical Diseases., Multicontrol Wedge Than Level 1, 6X5 Ml. Freeze-Dried Serum With Certified Analyte Values Corresponding To Normal Values For Test Quality Control: Alb; Alp; Alt; Amy; Ast; Db-Dsa; Db-Vox; Tb-Dsa; Tb-Vox; Ca; Tc; Ck; Crea-S; Glu-Hk; Glu-O; Ggt; Hbdh; Iga; Igg; Igm; Ldh; Mg; P; Tp; Tg; Urea; Ua; Fe; Che; Lip; Na+; K+; Cl-; C3; C4; Crp; Hs-Crp; Apo-A1; Apo-B; Hdlc; Ldlc; Pa; Ck-Mb; Aso; Trf; Fer; Uibc From The Kit Is A Closed-Type Biochemical Analyzer Mindray Bs-240Pro Without Arbitrary Methods. When Diluting Lyophilic Serum, The Volume Of The Finished Calibrator Is At Least 30 Ml. The Multicalibrator Kit Must Be Equipped With A Special Barcode Compatible With The Analyzer’S Built-In Scanner To Automatically Read Reference Test Values Into The Analyzer’S Memory., C-Reactive Protein R1: 1X40 Ml + R2: 1X10 Ml. A Two-Component Set Of Reagents For Determining C-Reactive Protein From The Mindray Bs-240Pro Closed-Type Biochemical Analyzer Kit Without Arbitrary Methods. The Reagents Are Packaged In Original Disposable Containers R1 (1 Bottle Of 40 Ml) And R2 (1 Bottle Of 10 Ml) To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Are Fully Adapted For The Reagent Carousel Of The Analyzer. Containers Must Be Equipped With A Special Barcode Compatible With The Built-In Scanner Of The Analyzer., Multicontrol Wedge Than Level 2, 6X5 Ml. Freeze-Dried Serum With Certified Values Of Analytes Corresponding To Pathological Ones For Quality Control Of Tests: Alb; Alp; Alt; Amy; Ast; Db-Dsa; Db-Vox; Tb-Dsa; Tb-Vox; Ca; Tc; Ck; Crea-S; Glu-Hk; Glu-O; Ggt; Hbdh; Iga; Igg; Igm; Ldh; Mg; P; Tp; Tg; Urea; Ua; Fe; Che; Lip; Na+; K+; Cl-; C3; C4; Crp; Hs-Crp; Apo-A1; Apo-B; Hdlc; Ldlc; Pa; Ck-Mb; Aso; Trf; Fer; Uibc From The Kit Is A Closed-Type Biochemical Analyzer Mindray Bs-240Pro Without Arbitrary Methods. When Diluting Lyophilic Serum, The Volume Of The Finished Calibrator Is At Least 30 Ml. The Multicalibrator Kit Must Be Equipped With A Special Barcode Compatible With The Analyzer’S Built-In Scanner To Automatically Read Reference Test Values Into The Analyzer’S Memory., Direct Bilirubin R1: 4X35 Ml + R2: 2X18 Ml - Two-Component Set Of Reagents For The Determination Of Dbil/Vox From The Mindray Bs-240Pro Closed-Type Biochemical Analyzer Kit Without Arbitrary Methods. The Volume Of The Working Solution Is 176 Ml. Packaged In Disposable Original Containers R1 And R2 To Prevent Contamination And Does Not Require Transfusion Into Additional Cartridges. The Containers Are Fully Adapted For The Analyzers Reagent Carousel And Are Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carry Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel, Immunoglobulin A (Iga) R1: 1 X 36 Ml + R2: 1 X 18 Ml. This Test Uses The Immunotransmission Turbidimetry Method, Which Is Used To Quantify The Content Of Immunoglobulin A In Human Serum In Vitro. It Is Of Great Reference Value For Diagnosis, Monitoring Of Disease Changes And The Effectiveness Of Treatment Of Relevant Clinical Diseases., Uric Acid R1: 4X40 Ml + R2: 2X20 Ml - Kit For Determining Uric Acid In Blood Serum From The Mindray Bs-240Pro Closed-Type Biochemical Analyzer Without Arbitrary Methods. R1-4X40ml, R2-2X20ml In Original Bottles. (Ua) (Uricase-Peroxidase Method), 902 Def. The Kit Must Be Marked With A Special Bar Code Compatible With The Closed System Reader., Alkaline Phosphatase R1: 4X35 Ml + R2: 2X18 Ml - Two-Component Set Of Reagents For Determining Alp From The Mindray Bs-240Pro Closed-Type Biochemical Analyzer Kit Without Arbitrary Methods. The Volume Of The Working Solution Is At Least 176 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted To The Reagent Carousel Of The Analyzer. Containers Must Be Equipped With A Special Barcode Compatible With The Built-In Scanner Of The Analyzer., Multicalibrator 10X3 Ml. Single-Level Multicalibrator For One-Component And Two-Component Tests From The Kit Mindray Bs-240Pro Closed-Type Biochemical Analyzer Without Arbitrary Methods. Freeze-Dried Serum With Certified Analyte Values For Test Calibration: Got/Alt, Got/Ast, Alb, Ams, Ggt, Glu-Godpap, Fe, Crea-J, Ldh, Mg, Bun/Urea, Tp, Tbil/Vox, Dbil/Vox, Chol/Tc, Tg, Alp, Ua. When Diluting Lyophilic Serum, The Volume Of The Finished Calibrator Is At Least 30 Ml. The Multicalibrator Kit Must Be Equipped With A Special Barcode Compatible With The Analyzer’S Built-In Scanner To Automatically Read Reference Test Values Into The Analyzer’S Memory., Urea R1: 4X35 Ml + R2: 2X18 Ml - Two-Component Set Of Reagents For Determining Bun/Urea From The Mindray Bs-240Pro Closed-Type Biochemical Analyzer Kit Without Arbitrary Methods. The Volume Of The Working Solution Is At Least 176 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted To The Reagent Carousel Of The Analyzer. Containers Must Be Equipped With A Special Barcode Compatible With The Built-In Scanner Of The Analyzer., Triglycerides R 4X40 Ml - One-Component Set Of Reagents For Determining Tg From The Mindray Bs-240Pro Closed-Type Biochemical Analyzer Kit Without Arbitrary Methods. The Volume Of The Working Solution Is At Least 160 Ml. The Reagent Must Be Packaged In The Original R1 Disposable Container To Prevent Contamination And Does Not Require Transfer To An Additional Cartridge. The Container Must Be Fully Adapted To The Analyzers Reagent Carousel. The Container Must Be Equipped With A Special Barcode Compatible With The Built-In Scanner Of The Analyzer., Calcium R 4X40 Ml - Two-Component Set Of Reagents For The Determination Of Calcium (Ca) (4*40Ml) Art: 105-000825-00 From The Kit Mindray Bs-240Pro Closed-Type Biochemical Analyzer Without Arbitrary Methods, Mindray Reagents Must Be Packaged In Disposable Original Containers R1 And R2, To Prevent Contamination And Do Not Require Transfusion Into Additional Ones Cartridges. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carry Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel
|