Bids Are invited for Customized Amc/Cmc For Pre-Owned Products - Annual Operation Maintenance Of Electrical Mechanical Installations In Integrated Operational Offices Building And 11 Kv Substation And Allied Works At Mumbai (2026-28); As Per Bid / Tender Document And.. - Operation And Maintenance Of Electrical & Mechanical Installations, Internal & External Ei Such As Light Fixtures, Fans, Light & Power Points, Lt Panels, Solar Street Lightning, Etc. By Carrying Out Operation, Repair, Maintenance, Attending To Complaints / Faults / Breakdowns And Taking Rectification Action, Ensuring Serviceability / Satisfactory Working Condition Of The Systems Installed In The Operational Offices Building I/C Preventive Maintenance, Maintenance Of Records / Documentation Etc. By Deploying Qualified Manpower In Two Shifts & General Shift (Each Shift Of Eight Hours) On All Working Days Including Sunday & Holidays As Per Special Conditions Of Contract & Additional Special Conditions Of Contract. , Operation And Maintenance Of Electrical & Mechanical Installations, Ht/Lt Panels, Synchronising Panel Of Dg Sets Etc. By Carrying Out Operation, Repair, Maintenance, Attending To Complaints / Faults / Breakdowns And Taking Rectification Action, Ensuring Serviceability / Satisfactory Working Condition Of The Systems Installed In The Substation I/C Preventive Maintenance, Maintenance Of Records / Documentation Etc. By Deploying Qualified Manpower In Three Shifts & General Shift (Each Shift Of Eight Hours) On All Working Days Including Sunday & Holidays As Per Special Conditions Of Contract & Additional Special Conditions Of Contract. , Operation Of 3 X 275Tr Water Cooled Screw Chillers Of Hvac System & Building Management System And Associated Equipments / Installations Viz, Chilled Water Pumps And Condensor Water Pumps, Cooling Towers, Ahus, Make-Up Water Tank, Expansion Tank, Hvac Panels Etc. Installed In The Operational Offices Building By Carrying Out Day To Day Operation And Maintaining Records / Documentation Etc. By Deploying Qualified Manpower In 2 Shifts (Each Shift Of Eight Hours) On All Working Days, Holidays & Excluding Sundays As Per Special Conditions Of Contract & Additional Special Conditions Of Contract. , Operation And Maintenance Of Water Pumping System Viz, Monoblock Pumps, Dewatering Pumps, Sewage Pumps, Dewatering Diesel Pump Etc. By Carrying Out Operation, Repair, Maintenance, Attending To Complaints / Faults / Breakdowns And Taking Rectification Action, Ensuring Serviceability / Satisfactory Working Condition Of The Systems Installed In The Operational Offices Building I/C Preventive Maintenance, Maintenance Of Records / Documentation Etc. By Deploying Qualified Manpower In In 2 Shifts (Each Shift Of Eight Hours) On All Working Days, Holidays & Excluding Sundays As Per Special Conditions Of Contract & Additional Special Conditions Of Contract. , Comprehensive Annual Maintenance Contract ( Camc) Of Façade Cleaning System Including Regular Maintenance Of Cradle, Motor, Winches, Gear Box, Rope Wires, Safety Device Etc. The Camc Includes Repairing Of Electric Control Box, Electric Switch Gear, Electric Motor , Gear Box, Winches, Checking Of Nuts Bolts, Wire Ropes, Replacement Of All Components Etc Complete As Required For Smooth And Trouble Free Operation Of Entire System . , Servicing And Testing Of Following 11 Kv Ht Panel Including Overhauling/Servicing Of Vcbs From Oem/Oem Authorised Agency, Of Following Ratings, Maintainance Of Complete Ht Panel Including Servicing & Testing Of Ct & Pt, Checking All Operational Mechanisms, Functions, Tripping Actions, Calibration Of Protective Relays & Testing With Secondary Current Injection Technique, Carrying Preventive Maintenance & Attending Breakdown Calls And And Submitting The Test Reports Accordingly Etc.Complete As Required. For Ioobincomer Panel:-630A, Tp Vcb :- 01 Nosoutgoing Panel:-630A, Tp Vcb :- 03 Nosmake & Model : Schneider & Hvx-X Type(Any Emergency Breakdown Visit Shall Be Attended Free Of Cost) , Servicing & Testing Of Following 11/0.433 Kv, Dry Type Cast Resin Transformers Of 1500 Kva, Volt Make By Carrying Out Preventive Maintenance Activity Of Transformer As Per Oem Recommendations To Keep The Transformer In Serviceable Condition. Work Includes Opening The Complete Encloser, Bus Bars, Ht & Lt Side Boxes, Cable Etc. Checking Of All The Safety Equipments, Cleaning, Servicing & Testing And Submission Of Service Reports Accordingly After Completion Of The Work As Per The Requirement.(Any Emergency Breakdown Visit Shall Be Attended Free Of Cost) , Servicing & Testing Of Following 11/0.433 Kv, Dry Type Cast Resin Transformers Of 1000 Kva, Kirloskar Make By Carrying Out Preventive Maintenance Activity Of Transformer As Per Oem Recommendations To Keep The Transformer In Serviceable Condition. Work Includes Opening The Complete Enclouser, Bus Bars, Ht & Lt Side Boxes, Cable Etc. Checking Of All The Safety Equipments, Cleaning, Servicing & Testing And Submission Of Service Reports Accordingly After Completion Of The Work As Per The Requirement.(Any Emergency Breakdown Visit Shall Be Attended Free Of Cost) , Overhauling /Servicing Of Following Schneider Make 415V Electrical Acbs From Oem/Oem Authorised Agency Integrated In Main Hvac Mcc Panel Including Checking All Operational Mechanisms, Functions, Positions, Tripping Actions As Per Oem Guidelines & Submitting Test Reports Accordingly Etc.Complete As Required. 1250 A, Fp Acb:- 03 Nos.800 A Fp Acb:- 04 Nos.(Any Emergency Breakdown Visit Shall Be Attended Free Of Cost) , Repair Of 10 To 15 Hp Submersible/ Monoblock Pump Including , Lifting And Lowering Of Pump From The Sump ( Approx 3 Lac Liter), Transportation And Copper Rewinding , Replacement Of Bearing, Seal Etc. Complete As Required. , Repair Of Up To10 Hp Submersible/Monoblock Pump Including , Lifting And Lowering Of Pump From The Sump ( Approx 40000 Liter), Transportation And Copper Rewinding , Replacement Of Bearing, Seal Etc. Complete As Required. , Repair Of 2X2 Ceiling Mounted Led Panel Lights Including Supply Of Drivers, Leds Etc Complete As Required. , Repair Of 36 W, 1X4 Ceiling Mounted Led Panel Lights Including Supply Of Drivers, Leds Etc Complete As Required. , Repair Of 25W/35W/40W Post Top Led L S Including Supply Of Drivers, Leds Etc Complete As Required. , Repair Of 70 W Led Street Lights Including Supply Of Drivers, Leds Etc Complete As Required. , Location And Finding Of Fault In Underground Lt Cable By Pin Pointing Method Etc Complete As Required. , Providing And Fixing Of Led Type Fixtures (Minimum 80 Led Lights Per Day) For Façade Lighting With Colour Changing Module On Rental Basis For Illuminating The Integrated Operational Offices Building, Rhq, Wr, Mumbai On Front Side Of The Building Replicating National Flag (Tri-Colours And Ashok Chakra) For 2 Days Including Providing Lighting Accessories, Manpower, Transportation Of Material To & Fro Complete Etc. As Required For Independence Day & Republic Day, Or As An When Required. , Provision Of 1.5 Tr Split Air Conditioners On Hiring Basis, Including Sitc, Transportation, Dismantling And Taken Back Complete As Required. , Provision Of 2 Tr Split Air Conditioners On Hiring Basis, Including Sitc, Transportation, Dismantling And Taken Back Complete As Required.
|