Quotation Are Invited For Rectify/Replace Hvac Control Panel @Utwn 132Kv. Rectify/Replace The Hvac Panelsubstation Name - Utwn 132Kvup Gradation Of Existing Johnson Controls Make "Hvac Control Panel Withjoh Nson Control Or Siemens Or Honeywell Controller" At Utwn Substationwith Latest Ddc Control System Including Supply, Installation, Testing &Commissioning.The Scope Of Work Include: -# Supply And Installation Of Advanced New Controller, Related Modulesand Hmi.# Remo Val Of Existing Controller, Modules And Related Wiring From Thehvac Panel And Installation Of New Controller.# Replacement Of Field Devices (Temp. Sensors And Dp Switches)# Replacement Of Room Temp. & Humidity Sensors.Notes:·#The Contractor Shall Visit The Site To Assess The Complete Scope Andquote For Lump Sum Accordingly. No Change In Price Accepted After Issueof Po.Dewa-Tl&C Electromechanic Al Maintenance Team Contacts:Engineer, Mr. Riyas Rahim - Mob.: 050-6863712 Or Sr. Engineer, Mr. Amroal Ali - Mob.: 050-8918877#For P Tw, Application Please Send Mail To - Ptw.Tcm@Dewa.Gov.Aepayment Terms And Conditions:Penalty: The Contractor Shall Complete This Wo Rk Within 6 Months Of Porelease Date, If The Work Is Delayed Beyond That Then; Dewa Is Entitledto A Reduction In The Po Value By 1.2 5% Per Week Of Delay And Subject Tomaximum 10% Of Po Value.Retention Amount: 5% Of The Total Value Of The Po Will Be Kept As Aretent Ion Amount For 1 Year After The Completion Certificate Is Issued,It Will Be Released To The Contractor Upon Clearing All Related Nod S.·#Upon The Issue Of Po, The Contractor Shall Obtain The Entry Permit(Permit To Work- Ptw) Approval, Prior To Start The Work, From Dewa-Tl&Cdepartment In The Prescribed Format. Upon Approval Of Ptw, The Worksshall Be Carried Out In The Presence Of Dewa-Tl&C Elect Romechanicalmaintenance Supervision Staff.·#The Delivery Note, Testing And Commissioning Report, Job Completionreport, Warranty Cert Ificate, Along With Po Copy Shall Be Submitted Todewa-Tam Within 15Days After Successful Completion Of The Work.Dewa-Tam Contact Eng Ineer For Submission Of Job Completion Documents:Mr. Mohammed Azeem Uddin (Ph: 04-3221689/ Mob.: 055-7728480). Qty: 1 Rectify/Replace Hvac Control Panel @Utwn 132Kv Contact Person For Site Visit: Mr Riyas - Mob: (050-6863712/04-3221448) Standard Terms & Conditions 1) Prices Should Be Ddp Delivery Duty Paid At Dewa Stores. 2) Quotation To Be Submitted Only In Local Currency U.A.E Dirhams 3) Dewa Standard Payment Terms Is 30 Days Credit From The Date Of Acceptance Of Material 4) No Dewa Staff Or His Or Her Relatives Up To Third Degree Should Have Ownership Or Partnership In Your Company, And Your Participation In Dewa Tenders / Rfqs Should Not Constitute A Conflict Or Perceived Conflict Of Interest. Supplier Registration: Https://Srm.Dewa.Gov.Ae/Irj/Portal/Anonymous/Regis Tender Link : Https://Srm.Dewa.Gov.Ae/Sap/Opu/Odata/Sap/Zsrm_Rfx_Reg_Bid_Srv/Attachmentset(2332601728)/$Value
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 116048681
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.