Tender for Schedule Of Quantities Nit No. Neist-29(521)/We-2026 Power Points Wiring Works To Mstd At Csir - Neist, Jorhat Sl No. Particulars Of The Item Unit Qnty Rate In Figures Rates In Words Amount In Rs. A B C D E F G=C*E , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Steel Conduit, With Piano Type Switch, Phenolic Laminated Sheet, Suitable Size Ms Box And Earthing The Point With 1.5 Sq.Mm Frls/Hffr Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. I Group C 2.0 Each , Wiring For Circuit/ Submain Wiring Along With Earth Wire With The Following Sizes Of Frls/Hffr Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Steel Conduit As Required. I 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 168.0 Mtr Ii 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 39.0 Mtr , Supplying And Fixing Following Piano Type Switch/ Socket On The Existing Switch Box/ Cover Including Connections Etc. As Required. I 15/16 A Switch 28.0 Each Ii 6 Pin 15/16 A Socket Outlet 28.0 Each , Supplying And Fixing Metal Box Of Following Sizes (Nominal Size) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc. As Required. I 100 Mm X 100 Mm X 60 Mm Deep 14.0 Each , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator). I 4 Way (4 + 12), Double Door 1.0 Each , Supplying And Fixing Of Following Ways Surface/ Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs (But Without Mcbs And Incomer ) As Required . (Note : Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required.) I 4 Way (4 + 12), Double Door 1.0 Each , Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. I Single Pole 12.0 Each Ii Triple Pole 4.0 Each , Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. I 63A 1.0 Each , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Ics=100% Icu And Operational Voltage 690V Etc. As Required. I 100 A,30Ka,Fpmccb 1.0 Each , Earthing With Gi Earth Pipes 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrengement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required , Supplying And Laying 6 Swg G.I Wire At 0.50 Metre Below Ground Level For Conductor Earth Electrode, Including Connection/ Termination With G.I Thimble Etc. As Required Total Tender Amount In Rs. Rupees ..................................................................................................................................................................................................... ................................................................................................................................................Only Nb Above Rates Are Inclusive Of All Government Levies. No Alternation Or Editing Of The Itemes Are Acceptable. Name Of The Quoted Firm : Firm Gstin No. Seal & Signature
|