|
Tender for Annual Rate Contract For Supply Of Neuro Implants In Tonk , Annual Rate Contract For Supply Of Neuro Implants , Gardener WellS Tong , Crutch Field Tong , Pedicle Screw System With Cobalt Chrome Multiaxial Head - Titanium (4.5 Mm, 5.5 Mm, 6.5 Mm, 7Mm, 7.5 Mm,) Polyaxial , Monoaxial Screws - All Sizes , Connecting Rods (Compatible With Above Mentioned Screws) -All Sizes. , Ha Coated Polyaxial Titanium Pedicle Screw (4.5 Mm, 5.5 Mm, 6.5 Mm, 7Mm, 7.5 Mm)-All Sizes , Fenestrated Polyaxial Titanium Pedicle Screw (4.5 Mm, 5.5 Mm, 6.5 Mm, 7Mm, 7.5 Mm)-All Sizes , Titanium Anterior Cervical Plating Sysrtem , Anterior Cervical Interbody Fusion Device. The Implant Should Act As Stand Aloneinterbody Fusion Device For Cervical Spine With The Benefits Of An Interbody Spacer And An Anterior Cervical Spine, The Implate Must Be A Combination Of Peek/Titanium Must Automatically Align When Inserted, The Implate Must Have Radio Opaque Marker For Posterior And Anterior Visualization During Imaging And Teth On Superior And Anterior Surface For Intial Stability, The Implant Must Have On Zero Step Locking Screw And Screw Loading Wire Should Form A Bone Wedge With 40*+_5, 25+_5 Cranial /Caudal Angle With 2.5 Or 0 Midine Lateral Angle, The Screws Must Come In 3.0Mm Diameter & Must Be Colour Coded By Screw Length Varying From 12-20Mm, Should Have Option For 2-4 Screws , Cv Junction Fixation System (Occiput To C2) The System Should Have Medial And Lateral Plates Of 50& 60Mm, One & Two Hole, Clamps Which Must Allow The Medical And Lateral Rod Placement, And Should Be Able To Give 15 Degree Of Screw Angulations, The System Must Have Straight And Pre Contoured 3.5Mm Rods, The System Should Have Blun T 4.5Mm Accipital Screws And 5Mm Emergency Screws With 4.18Mm Lengths. , Top Loading Implant System For Posterior Stabilization Of The Cerivical Spine. The System Must Have Self/Tapping Screws, The System Must Have 3.5Mm Ti Rod ), The System Should Have Cancellous Profile Bone Screws: 3.5Mm: 8Mm-50Mm(2Mm Increments) 4.0Mm: 8Mm-50Mm(2Mm Increments) , Expandable Corpectomy Cages. A) Expandable Verterbral Body Replacements B) For Cervical & Upper Thoracic Spine C) Should Have Ratchet System So That Height Can Be Achieved. D) Should Achiever Height From 17Mm To 70Mm & Angle From 4.5 To 7 Degree E) Should Be In Radiolucent -Peek Material , Titanium Mesh Cage For Vertebral Body Replacement Per Mm A) For Cervical Round/Oval B) Thoraco / Lumber-Round/Oval , Sublaminar Titanium Cable System , Cage And Titanium Staples For Anterior Fiaxtion , Poly Ether-Ether Ketone (Peek ) Spacer For Cervical Spine A) Spacer Should Be Made Of Radiolucent Poly Ether-Ether Ketone. B) Spacer Be Designed For Use With Open, Mini And Endoscopic Techniwue. C) Should Have Space For Filling The Bone Graft. D) Should Be Of Anatomical Design To Fit The Cervical Spine. E)Should Be Available In Varius Sizes. G) Should Have Radio Opaque Markerto Identify The Location Of The Spacer At The Time Placement. , Odontoid Screw , C1-C2 Transarticular Screw , Side Opening Pedicle Screw System , Transformational Lumber Interbody Fusion Cage The Cage Must Be Radiolucent Made Up Of Peek - Optima Material With Sharp Teeth Designes For Transformational Lumbar Interbody Fusion (Tlif), The Cage Must Have Biconvex Shape Providing Even Distribution Of Compressive Forcess Along The Endplates Thus Stability, The Cages Must Have One Broad Graft Hole And Two Lateral Holes, The Cages Must Be Pre Filled With Chromos, Synthetic Bone Graft, Implants Must Be Available In Two Footprint Sizes 10*27Mm And Are Available As Sterling Packed, The Available Implant Heights Must Be 7Mm, 8Mm, 9Mm, 10Mm 11Mm, 12Mm, 13Mm, 15Mm, 17Mm , Posterior Lumbar Interbody Fusion Plif Cage Must Be Made Of Peek Material Preferably Radiolucent, Cage Must Have Two X-Ray Markers Integrated Into The Cages To Enble Easy Visualization Of Their Position Postoperatively, Cages Must Available In 6 Heights In 2Mm Increments, And Should Be Supplied Sterle Packed, The Optimal Anatomical Shape And Supportive Superior And Inferior Surface Design Of Cage Should Reduces The Risk Of Subsidence Into Adjacent Vertebrate, The Cage Should Have Perforated Structure Which Must Allows For Bony Ingrowth Throught Cage And The Design Must Ensures Optimal Implant-To Endoplate Contact , Artifical Lumber Disc , Kyphoplasty And Vertebroplasty Kit , Cage And Titanium Staple For Anterior Fixation , Multilevel Percutaneous Pedicle Screw Fixation For Thoraco - Sacral Fixation . Minimally Invaive Multilevel Percutaneous Pedicle Screw Fixation Sysrem For Thoracic As Well Lumbar Fixation With Capability Of Putting At Least 8 Screws Percutaneously, Compatible With Separate Incision Technique For Screws And Rods, System Should Have Straight Rod, Can Be Bend As Per The Anatomy Of Thoracic And Lumbar, System Should Have Steerable Rod Inserter And Reduction Screw Extenders, The Reduction Screw Extender Should Have Large Window At The Base Of The Screw Extenders, System Should Have Free Hab=Nd Rod Inserter Instrument, System Should Provide Unique Method Of Compression And Distraction, Rod Approximation And Rod Rotation (Through The Percutaneous Rourte), System Should Allow Gradual Dilation To Minimize Muscle Trauma, Fascia Disruption And Blood Loss, System Should Be Compatible With Both Mono And Axial Screws Capabilities, The Screws Should Have Top Loading , Top Tightening And Most Importantly Reverse Threa Technology With Breakoff Plugs, System Should Have Cannulated Mono And Multi -Axial Screws With Angulation Of 28 Degree And Should Be Available In Self Tapping Screws 4.5, 5.5, 6.5, 7.5Mm Diameter And Lengths 25-60Mm At The Increment Of 5Mm, Should Be Compatible For Use With Fenestrated Screws For Augmenting Vertebral Bodies Cement, System Should Becompaatible With 5.5Mm Rod, System Should Works With Jamshedi Needle. , Laminar Hook With Rod Should Be Made Up To Titanium/ Mri Compatible Material And Of Different Sizw And Angles With Two Rods And Screw , Hartshill Should Be Madceep Of Titanium Or M.R.I. Compatible Of Difle Size With Bott Wire , Mini Plates & Screws , Plats For Craninal Fixations , Craninal Fixation System , External Drainage And Monitoring , Fixed Pressure Ventricedopertioneral Of Atrial Shunts With Or W/O Siphon Control Device , Adjustable Pressure Valves/Shunts , Titanium Mesh For Cranioplasty , Dural Graft Implant (Absorbable Collagen Matrix A) Should Be Onlaydural Graft B) Should Be Bioabsorbable C) Suturing/Gluing Should Not Be Required. D) Should Be Sterile. A) Should Be Of 1*3 Size Sponge B) Should Be Of 2*2 Size Sponge , Biological Fibrin Glue With Calcium & Chioride & Aprotinin Kit 2 Ml , Methymetha Acrylate Bone Cement , Maemostatic Matrix Contains-Gelatins In Syring Calcium Chloride And Human Thrombin 5Ml , Percutaneous Tracheostmy Kit With Guidewire Dilating Forcepss , Neuro Muscular Transmission Monitor , Fluid Warmer Machine , Positive Presoor Surgical Helmet System , Surgical Loop , Shaver Burr For Hsd , Neuro Redio Requency Probe , Vaccume Dressing Machine , Vac Dressing Sterile , Lumbo Peritoneal Shunt , Aneurysm Clip (Sugita Type) Should Be Madeup Of Titanium /Mri Compatible Material , Disposable Perforator 12/14Mm Should Be Of 9Mm, 11Mm, 14Mm Size, Should Include Both Burr And Perforator With Dural Guard, Should Have Colour For Size Variation, Should Be Sterile. , Anterior Cervical Locking Plate- It Should Be Made Commercial Pure Medical Grade Titanium -Profile Of The Plate Must 2.0 Mm - 2.5Mm -Width Of The Plate 16Mm-17.5Mm Wide. -Screw Must Be Available From 12Mm To 18Mm Length, Self Tapping & Self Drilling & Variable Angel & Fixed Angel Screw Option -Cranial Screw Angulation Must Be 6 Degree. , Anterior Cervical Interbody Fusion Device With Screw- The Implants Should Be Made From Radiolucent Peek To Enable To Optimal Visualisation Of Fusion. The Implants Should Be Stand-Alone Interbody Fusion Device For C-Spine Spacer Component Must Be Made Of Peek/Titanium. The Implants Must Vote In Parallel Lordotic & Convex Implants Sets With Hights Varying From 5Mm- 9 Mm. Implant Must Have On One Step Locking Screw & Screw Angulation Must 40° & 8° Degree Increase & Decrease. Screw Should Be Dual Threaded. Should Have Option For 2 Screws. Screw Must Have Cortical-Cancellous Thread Design In 3.5 & 4Mm Diameter. , Anterior Cervical Interbody Fusion Cage- Cage Should Be Peek /Titanium Material. Should Have Radiopaque Marker Which Add In Proper Positioning Of Implants Hights 5Mm - 10Mm. Implants Must Have 6° Lordotic Curve. Cage Must Have Graft Window For Bonegraft. , Odontoid Screw - Screw Should Be Made Up Of Titanium Alloy (Tan) Screw Should Be Cannulated & Self-Drilling Screw Should Consist Of 10- 12Mm Short Thread Screw Should Be 4Mm Diameter & Length Of 36Mm-50Mm The Whole System Should Be Compatible To Screw Insertion. , Cervical Round/Over Mesh Cage - Diameter- 10Mm- 16Mm Length- 10Mm- 100Mm , Thoracolumbar Vertebral Body Replacement Mesh Cage - Diameter- 13Mm- 22Mm Length- 10Mm- 100Mm , Sublaminar Titanium Cable System- The Cable Should Be Made Of Multiple Strand Of Titanium To Enable Better Grip Over Tissues. The Individual Packaging Should Be Available Double Cable & Single Cable Individual Sterilized Packing. It Should Be Malleable With Crimp. It Should Be Of Medical Grade Titanium And Should Be Artefact Free On Mri & Ct Scan. , Disc Prosthesis For Cervical Spine- Anatomical Footprint Design For Maximum Endplate Coverage . -Three Different Heights (5, 6, & 7Mm) Allowing Adjustment To The Individual Dimensions Of The Disc, & Depth Available In 12,14,16 & 18Mm -Superior & Inferior Implant Plate Made Of Titanium Alloy Ceramic Composite In Two Pieces Implant. - Ball & Trough Based, Plasma- Sprayed Titanium Coating. , Plif/ Tlif Cage- Plif/ Tlif Cage -The Implant Must Be Radiolucent Made Up Of Peek- Material With Sharp Serrated Edge. -The Implants Should Have Range Of Hight 8Mm- 15Mmin 1Mm Or 2Mm Incremental To According Patient Anatomy. -The Implants Have Marker To Indicate Cage Position On X-Ray. - The Implants Must Have A Bone Graft Window. - The Implants Available In 22Mm, 26Mm & 32Mm Length. , Olif Cage- -The Implant Must Be Radiolucent Poly Ether Ether Ketone. Should Have Space For Filling The Bone Graft. Should Be Self Distracting Bullet Shaped With Convex Shap Designed To Fit Patient Anatomy. Should Be Available In Various Lordotic Options Of 0 Degree, 6 Degree & 12 Degree & Diameter Start From 8Mm To 16Mm In Increment Of 2Mm. Should Have 5Mm Cage Length In Front Of The Cage Markers Which Should Be Visible In Ap X-Ray View. Should Be Available In Different Lengths 40Mm, 45Mm, 50Mm, 55Mm & 60Mm. Should Have An Anterior Nose Head Of 5Mm For Easier Insertion. Should Be An Impacted Cage System Compatible With Minimally Access Technique. Should Be Able To Undergo Orthogonal Maneuvers. , Polyaxial/Monoaxial Pedicle Screw System - The System Must Have In Medical Grade Titanium Alloy. The System Should Be The Pedicle Screw System For Posterior Stabilization Of The T/L Spine. System Should Be Low Profile. System Should Be Available In Length Of 25Mm- 50Mm & Diameter Should 4.5Mm-7.5Mm With 25°-45°Angulation. The System Must Have Polyaxial Pedicle Screw & Reduction Screw & Transverse Bars With Various Length. System Must Have The Option Of The Rod 5.5/6Mm , Pedicle Screw System With Cobalt Chrome Multiaxial Head - Titanium (4.5 Mm, 5.5 Mm, 6.5 Mm, 7Mm, 7.5 Mm,) Polyaxial , Percutaneous Pedicle Screw Fixation System- The System Should Single & Multiple Level Capability. The System Should Have Polyaxial/ Monoaxial Screw With Top Loading Locking Mechanism. Implants Should Be Cannulated Poly Axial With 4.5, 5.5 & 6.5Mm Dia Screw For Percutaneous Thoracolumbar Fixation With Break Off Set Screw. System Should Have Rod Option For Pre-Cut& Prebend & Straight Of Different Sizes. System Should Have Free Hand Rod Inserter Instruments. System Should Have For Measuring & Rod Confirmation Tool Which Help To Surgeon To Check The Insertion Of The Rod On To The Screw Percutaneously. System Should Provide Unique Method Of Compression & Distraction. - System Should Be Compatible With Enabling Technology Which Is Installed In Organisation. - System Should Have Cannulated Instruments For Ease Of Working On Guide Wire. The System Should Have Reverse Threaded Technology To Reduce Pull-Out Strength. Implants Should Be Top Loading, Top Tightening & Most Importantly Reverse Thread Technology With Break Off Plugs. System Should Compatible With 5.5Mm Dia Rod. System Should Be Available For Demonstration As Per Therequirement. , Demineralized Bone Metrix Bone (Dbm)- Should Be Having The Capability For Both Osteoconduction And Osteoindution. Should Be Available In Putty Form. Should Be Available In 3 Sizes Based On Volume Of Graft- 1Cc, 2.5Cc & 5Cc. Should Be Available In Sterile Packing. , Bmp- Graft- Single Protein- Bone Morphogenic Protein (Rhbmp2) Size Available In - X Small (1.4Cc), Small (2.8Cc), Medium (5.6Cc), Large (8Cc). , Synthetic Granules Bone Graft- Synthetic Bone Graft Substitute With Recordable Ceramic Granules. -Graft Should Have Hydroxyapatite (Ha) 15%. -Graft Available In Sterile Packaging. -Graft Available In Based On Volume 5Cc & 10Cc. , Bone Cement- Synthetic Pmma & Hydroxyapatite Combine With Osteoconductivity. -Should Be 50% Hydroxyapatite In The Powder Component. -Should Be Long Working Time & Low Exothermicity. -Should Be Use In Kyphoplasty & Vertebroplasty Surgeries. -Should Be In Sterile Packing. , Lateral Mass & Occipitocervical Module- Three-In-One Set Of Options That Provide Adjustability, Flexibility & Adaptability To Accommodate For Anatomical Challenge Within Occipitocervical Spine. System Implant Should Give Surgeon Choice Of Adjustable Oc Plate, Midline Plate, Rod, Screws & Screw Connector. System Should Have Polyaxial Lateral Mass Screw In 3.5Mm & 4.0Mm Diameter & Length Should 10Mm To 30Mmm With 2Mm Increment. System Should Have Reverse- Angle Design & 45 Degree Angulation With Smooth Tulip Head. System Must Have 3.5Mm Diameter Titanium Rod & Cobalt Cronium Rod. System Should Have Adjustable 4Mm Occipital Plate Between The Two Rods. System Should Have Cortical Bone Screw In Sizes- 4Mm, 4.5Mm & 5Mm Dia & Length 6Mm To 12Mm With 2Mm Increment. System Should Have Lateral Offset Connector Accommodate Medial- Lateral Flexibility In Challenging Rod/ Screw Alignment Situation. System Should Have Hooks In The Set. System Should Have Transverse Connector. System Should Be Available For Demonstration As Per The Requirement. , Expandable Corpectomy Cage- ? Expandable Vertebral Body Replacement For Cervical & Upper Thoracic Spine. ? System Should Offer A Variety Of Centrepiece Diameter &System Should Be Available For Demonstration As Per The Requirement. End Cap That Offer Surgeons The Flexibility Need To Treat Patients Through A Lateral, Anterior Or Posterio- Lateral Surgical Approach. ? System Should Have Kyphotic/ Lordotic End Cap Option Of 4°, 8° And 15°. ? System Should Have A Release Mechanism That Allows Implants Adjustment Or Removal From Any Surgical Approach Regardless Of Initial Insertion Approach. ? System Should Have Cage Diameter Form 13Mm, 16Mm, 19Mm, 22Mm & 25Mm With Hight Ranging 16Mm To 124Mm. ? System Should Also Have 1.2Mm Incremental Expansion With Self Locking Feature. ? System Should Have A Self-Locking Mechanism. ? System Should Have Colour Coding For Ease Of Use. ? System Should Have Ergonomically Designed Instruments. , Kyphoplasty & Vertebroplasty Kit- The Kit Should Be Available In Pre-Sterile. Should Have Working Cannula With Inner Diameter 3.2Mm Or Less Outer Diameter 4.2Mm Or More With Calibration Along With Cannulated Obdurator. Should Have Calibrated Drill With Cm/Mm Marking On Proximal End. Should Have Digital Battery Operated Inflation Syringe To Inflate The Balloon Showing Pressure In Psi & Atm. Inflation Time & Volume Of Cavity Created In Vertebral Body. The Inflatable Balloon Tamps Sizes- 10/3, 15/3, 20/3. (Either Size) Should Be Capable To Bear Pressure Of 400 Psi & 700 Psi. The Bone Filler Device Should Be Calibrated & Should Contain Minimum 1.5Cc Of Volume. Anterior Radiopaque Marker On Balloon Tamp Should Be Mark The Anterior Edge Of The Balloon. System Component Should Be Available In Individually As Well As In Kit From Including The Following Instruments- 1. 2 Unit Of 11-Gauge Bone Access Needle. 2. 1 Introducer Kit Including Introducer With Extra Cannula. 3.Drill With Drill Tip. 4. At Least 4 Guide Pins. 5. Two Balloon Tamp+C20 6. 2 Digital Balloon Inflator. 7. Six Bone Filler Device.
|