|
Tender for (Schedule-A Part-I B/R Works)Excavation In Trenches In Any Type Of Soil Not Exceeding 1.5M Wide And Not Exceeding 1.5M Depth For Foundation Etc Or For Shaft, Wells, Cesspits, Manhole, Drain, Pair House Etc Not Exceeding 10 Sqm On Plan And Not Exceeding 1.5 M Depth And Getting Out In Any Type Of Soil Complete All As Specified And Directed. , Returning Filling In Including, Spreading, Leveling Watering And Well Ramming In Layer Not Exceeding 25Cm In Each Layer In Any Type Of Soil Complete All As Specified And Directed. , Removing Excavated Material Not Exceeding 50 M And Depositing Where Directed At Level Not Exceeding 1.5M Above The Starting Pointing Complete All As Specified And Directed. , M&L For Plain Cement Concrete 1:4:8 Type D2 Using 40Mm Graded Aggregateas In Foundation Complete All As Specified And Directed. , Demolition Of Brick Work/Stone Boulder Masonry Built In Cement Mortar Including All Quions, Arches, Pillars Etc But Excluding Ashlar Facings Dressed Stone Work And Precast Concrete Articles Complete All As Specified And Directed. , Demolition Of Cement Concrete (Unreinforced) In Ground Floors And Paving Not Exc 15Cm Thickness Complete All As Specified And Directed. , Demolition Of Cement Concrete (Unreinforced) Of Any Description And Any Position Not Other Wise Specifically Provided Complete All As Specified And Directed. , Demolition Of Cement Concrete (Reinforced) Of Any Description And Any Position Not Other Wise Specifically Provided Reinforcement Cut As Required To Facilitate Demoltion Complete All As Specified And Directed. , M & L For Reinforced Cement Concrete (M-25 Design Mix) In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies,Canopies, Deck Slabs And In Shelves And The Like (20 Mm Graded Aggregate)Complete All As Specified And Directed. , M & L For Form Work To Soffits Of Suspended Slabs Such As Roof Slab, Floor Slab, Landing And Similar Works, N Exc 200Mm Thick(Horizontal Or Sloping) Complete All As Specified And Directed. , M & L For Brick Work With Sub Class B (Old Size) Brick Straight Or Curved On Plan Exc 6 M Mean Radius In Cm 1:4 Complete All As Specified And Directed. , M&L Walling Of Polygonal Rubble, Uncoursed As Well Bonded, Bedded Solidly Hearted,Built In Cement Mortar 1:4 Cm Except Stone Complete All As Specified And Directed. , M & L For Raised Pointing To Random Rubble Masnoary In Cm 1:4 Etc Complete All As Specified And Directed. , M&L For Plain Cement Concrete 1:2:4 Type B1 Using 20Mm Graded Stone Aggregate In Coping Complete All As Specified And Directed. , M&L Plain Cement Concrete 1:2:4 Type B2 Using 40Mm Graded Stone Agregrate As In Surface Channel And Drain Complete All As Specified And Directed. , Taking Down Cement Plaster On Brick Or Stone Wall Etc Including Racking Out Joints, Hacking For Key Scrubbing Down With Water Etc To Receive New Plaster Etc. Complete All As Specified And Directed. , M&L Rendering In Cm 1:4 15Mm Thick On Block Masonry Finished Even And Fair Without Using Extra Cement Complete All As Specified And Directed. , M&L For Extra For Forming Fair Finished Drain Or Channel 45Cm Inner Girth In Cement Concrete Using Extra Cement Including Form Moulds Mitred/Stopped Ends Etc. Complete. , M&L Tmtbars10 Mm And Over Dia Cut To Length Bent To Shape Required Including Bending Hooking, Binding With Ms Wire Not Less Than 0.9 Mm Dia Complete All As Specified And Directed. , M&L Tmtbars 6Mm To 8Mm Dia And Over Dia Cut To Length Bent To Shape Required Including Bending Hooking, Binding With Ms Wire Not Less Than 0.9 Mm Dia Complete All As Specified And Directed. , M & L For Providing Pre Cast Reinforced Cement Concrete Cover Slab 1: 2: 4 Type B1 Using 20Mm Graded Trap Stone Agg Set Cm 1:4 All As Spd And As Directed Complete All As Specified And Directed. , M&L Plain Cement Concrete 1:4:8, Type D2( Using 40Mm Graded Stone Aggregate) 75Mm Thick As In Sub Base Of Floor Complete All As Specified And Directed . , M&L In Repair For 60Mm Thick Machine Pressed Precast Concrete Interlocking Paver Block (Glossy Finish) Of M-35 Gde Of Approved Shape, Size And Colour Conferming To Is 15658-2006 And Laid Over And Including 25Mm Thick Sand Cushion Complete All As Specified And As Directed. , M&L In Repair For 80Mm Thick Machine Pressed Precast Concrete Interlocking Paver Block (Glossy Finish) Of M-40 Gde Of Approved Shape, Size And Colour Conferming To Is 15658-2006 And Laid Over And Including 25Mm Thick Sand Cushion Complete All As Specified And As Directed. , M&L For Following:- (A)Taking Down Cement Plaster Of Any Description From Brick Stone Walls Or Concrete Surface Including Racking Out Joints, Hacking For Keys Scrubbing Down With Water Etc. (B) M&L Rendering 15Mm Thick In Cement Mortar 1:4 In Layer ( 10 Mm + 5Mm ) Mixed With Pd Proof 101 Lw (Or +) Of Dr Fixit Or Equivalent Integral Wp Admixture @ 200 Ml/Bag Of Cement Over Two Coats Of Super Latex 302 Of Dr Fixit Or Eqv In The Ration 1:4:7 (One Part Super Latex 302, 4 Part Water And 7 Part Cement) @ 1050 Kg Of Homogeneous Mixture Per Sqm In Two Coats And Finished The Surface Even And Fair Without Using Extra Cement Complete All As Specified And Directed Note : Pd Proof 101 Lw (Or+) And Super Latex 302 Shall Be Measured And Paid Separately , Supply Only Intregral Liquid Waterprooing Compound Complete All As Specified And Directed. , Supply Only Sbr Based Latex For Waterproofing Complete All As Specified And Directed. , M & L For Preparing New Plastered Surfaces Of Wall And Applying Two Coats Of Distemper Oil Emulsion Over A Coat Of Alkali Resistant Cement Primer And Over A Coat Of 2 To 3Mm Thick Wall Care Putty Complete All As Specified And Directed. , M&L For 150 Mm Bore Salt Glazed Stone Were (Sgsw) Drain Pipe Grade A Laid To Slope In Tranches And Jointed In Cement Mortar (1:1) Including Necessary Testing For Ensuring Teak Proofing Complete All As Specified And Directed. , All As Per Above Item No 29 But 200 Mm Dia Bore Pipe Complete All As Specified And Directed. , M&L For Concrete Bed To Drain Pipes Including Packing Under, And Haunching Against The Sides Of 150 Mm Bore Pipes In Cement Concrete 1:3:6 Type C-2 ( Using 40 Mm Graded Stone Aggregate) After They Are Laid And Tested Complete All As Specified And Directed. , All As Per Item No 31 But 200 Mm Bore Of Pipe Complete All As Specified And Directed.. , M & L For Cutting Into Existing Manhole For Connecting New Drains Making Good To Pipe And Rendering Cutting Out Existing Benching For And Ternning Branch Channel (1/2 Round As 3/3 Section) In Cement Concrete Type B-1 1:2:4 Smoth Finished And Benching As Required For 150 Mm Pipe Complete All As Specified And Directed. , All As Per Above Item No 33 But 200 Mm Dia Bore Pipe Complete All As Specified And Directed. , Demolition And Breaking Up 150Mm Dia Drain Pipes (Salt Glazed Ware, Ac Or Reinforced Concrete ) And Set In Cement Mortar Complete All As Specified And Directed. , Demolition And Breaking Up 200 Mm Dia Drain Pipes (Salt Glazed Ware, Ac Or Reinforced Concrete ) And Set In Cement Mortar Complete All As Specified And Directed. , S&F Steel Fibre Reinforced Concrete Manhole Cover Of Size 1200X500x65mm Thick With Angle Iron Frame Set In Cm 1:4 Complete All As Specified And Directed.
|