Filter Rb-Ftov-N13-1150*550-78/513/10/00/00/K50. Absolute Purification Filter Fva-1 Fva-1 Is A Final (Absolute) Stage Air Purification Filter Made From Microfiberglass Reinforced With An Aluminum Separator. Complies With H13 Standards. • The Body Is Made Of Steel (Galvanized/Stainless); • Planting Depth Reaches 150 Mm And More; • The Material Is Fixed Using Two-Component Glue Along The Entire Perimeter, And Not Just At The Ends; • 100% Tightness Of The Structure; • Optional Installation Of Protective Nets And Seals. • Production Of A Filter Frame With A Flange Or Flange According To Individual Sizes; • Work At High Temperatures; • Application: In Air Conditioning Systems, Clean Rooms, Various Laboratories, Surgeries; • Possibility Of Treatment With Disinfectants And Cleaning Agents; • All Manufactured Products Have A Declaration Of Conformity And A Sample Test Report; • Filters Are Tested In Accordance With Gost R En 1822-4:2012, A Product Passport Is Provided; • The Ability To Provide A Test Report For The Batch, For Compliance With The Cleaning Class And Particle Leakage; • Individual Packaging Of The Goods In Polyethylene Film, Additional Protection Of The Filter Material With 5 Mm Thick Mdf Inserts On Both Sides Of The Filter. Characteristics: Filter Material - Microfiberglass With An Aluminum Separator. Case Material - K0 - Galvanized Steel, K1 - Stainless Steel, Material Fixation - Two-Component Glue. Filter Package Thickness, Mm - 130, Cleaning Class - H13, Filter Rb-Ftov-N13-550*550-78/513/10/00/00/K50. Absolute Purification Filter Fva-1 Fva-1 Is A Final (Absolute) Stage Air Purification Filter Made From Microfiberglass Reinforced With An Aluminum Separator. Complies With H13 Standards. • The Body Is Made Of Steel (Galvanized/Stainless); • Planting Depth Reaches 150 Mm And More; • The Material Is Fixed Using Two-Component Glue Along The Entire Perimeter, And Not Just At The Ends; • 100% Tightness Of The Structure; • Optional Installation Of Protective Nets And Seals. • Production Of A Filter Frame With A Flange Or Flange According To Individual Sizes; • Work At High Temperatures; • Application: In Air Conditioning Systems, Clean Rooms, Various Laboratories, Surgeries; • Possibility Of Treatment With Disinfectants And Cleaning Agents; • All Manufactured Products Have A Declaration Of Conformity And A Sample Test Report; • Filters Are Tested In Accordance With Gost R En 1822-4:2012, A Product Passport Is Provided; • The Ability To Provide A Test Report For The Batch, For Compliance With The Cleaning Class And Particle Leakage; • Individual Packaging Of The Goods In Polyethylene Film, Additional Protection Of The Filter Material With 5 Mm Thick Mdf Inserts On Both Sides Of The Filter. Characteristics: Filter Material - Microfiberglass With An Aluminum Separator. Case Material - K0 - Galvanized Steel, K1 - Stainless Steel, Material Fixation - Two-Component Glue. Filter Package Thickness, Mm - 130, Cleaning Class - H13, Vn 600*350-3R-14T-7K-D28-Sh2.5 705*390-S150-N35-E20-F20-K43.3-L200_P1v_Ots1.0 . Air Heater For Heating Purpose Of The Heater: The Ksk Water Heater With Bimetallic Spiral-Rolled Aluminum Fins Of Heat-Transfer Elements Is Intended For Heating Air With The Maximum Permissible Content Of Chemically Aggressive Substances In Accordance With Gost 12.1.005-88 With A Dust Content Of No More Than 0.5 Mg/M³, Which Does Not Contain Sticky Substances And Fibrous Materials In Ventilation Systems, Air Heating And Air Conditioning. The Ksk Heater Is Designed For Operation In Areas With A Temperate Climate, Location Category 3 According To Gost 15150-69. The Coolant Temperature Is Water No More Than 150°C And The Pressure Created By The Pumps In The System Is No More Than 1.2 Mpa. Design And Principle Of Operation Of The Heater: The Ksk Heater Consists Of Heat-Transfer Elements, Tube Sheets, Covers And Removable Side Shields. For Installation And Fastening Of Heaters During Installation, 11X15 Oval Holes Are Provided On The Sides Of The Tube Sheets And Removable Shields. The Connecting Dimensions Of All Heaters With A Single Pitch Of 125 Mm Make It Possible To Assemble Heaters In Height And Length And Assemble A Heater Installation With An Air Capacity Of Up To 500 Thousand M³/Hour. The Heat Transfer Element Is Made Of A 16X1.5Mm Steel Pipe And Aluminum Knurled Fins With A Diameter Of 39Mm. The Pitch Between The Ribs Is 3Mm. Depending On The Number Of Coolant Strokes, Side Covers With Partitions Are Welded. Warranty Period - 12 Months. Technical Characteristics Of Air Heaters. The Main Indicators For The Purpose Of Heaters Are Shown In The Table For The Standard Operating Mode With The Following Parameters: Water Heater (Ksk): - Air Inlet Temperature - -20°C. - Mass Air Velocity In The Oncoming Flow - 3.6 Kg/M².S - Inlet Water Temperature - 150°C - Outlet Water Temperature - 70°C., Vn 200*250-3R-10T-5K-D28-Sh2.5 605*290-S150-N35-E20-F20-K43.3-L200_P1v_Ots1.0 . Heater For Heating Purpose Of The Heater: The Ksk Water Heater With Bimetallic Spiral-Rolled Aluminum Fins Of Heat-Transfer Elements Is Intended For Heating Air With The Maximum Permissible Content Of Chemically Aggressive Substances In Accordance With Gost 12.1.005-88 With A Dust Content Of No More Than 0.5 Mg/M³, Which Does Not Contain Sticky Substances And Fibrous Materials In Ventilation Systems, Air Heating And Air Conditioning. The Ksk Heater Is Designed For Operation In Areas With A Temperate Climate, Location Category 3 According To Gost 15150-69. The Coolant Temperature Is Water No More Than 150°C And The Pressure Created By The Pumps In The System Is No More Than 1.2 Mpa. Design And Principle Of Operation Of The Heater: The Ksk Heater Consists Of Heat-Transfer Elements, Tube Sheets, Covers And Removable Side Shields. For Installation And Fastening Of Heaters During Installation, 11X15 Oval Holes Are Provided On The Sides Of The Tube Sheets And Removable Shields. The Connecting Dimensions Of All Heaters With A Single Pitch Of 125 Mm Make It Possible To Assemble Heaters In Height And Length And Assemble A Heater Installation With An Air Capacity Of Up To 500 Thousand M³/Hour. The Heat Transfer Element Is Made Of A 16X1.5Mm Steel Pipe And Aluminum Knurled Fins With A Diameter Of 39Mm. The Pitch Between The Ribs Is 3Mm. Depending On The Number Of Coolant Strokes, Side Covers With Partitions Are Welded. Warranty Period - 12 Months. Technical Characteristics Of Air Heaters. The Main Indicators For The Purpose Of Heaters Are Shown In The Table For The Standard Operating Mode With The Following Parameters: Water Heater (Ksk): - Air Inlet Temperature - -20°C. - Mass Air Velocity In The Oncoming Flow - 3.6 Kg/M².S - Inlet Water Temperature - 150°C - Outlet Water Temperature - 70°C.
|