|
Tender for Cctv Installed At Sindhi Tiraha, Kumher Tiraha, Railway Gate Outside, Near Anaj Mandi, Axis Bank Tiraha, Maharampur Road Intersection, New Court Bailara, Bailara Intersection And Other Places In Municipal Area Nadbai. Camera Installation Work. , Supply Installation Testing and Commissioning of 55 4K Resolution Or Better Led Tv With Remote Control And Wall Mount Unit / Floor Stand Complete With Making Connections Etc. As Required. , Supply, Drawing And Testing Of 4 Pair, 23 Awg Solid Bare Copper Wire Insulated With Hdpe, Category 6A/Class Ea, U/Ftp (Unscreened/Foiled Twisted Pair), 100 Ohm Impedance, Indoor Cable As Per Latest Amendments Of Ansi/Tia/Eia-568 C.2 & Iso/Iec 11801 2Nd Ed, The Copper Conductors Should Be Balanced Twisted In Pairs, Unscreened And Aluminum Foil Shielding Of Individual Pairs Protected By A Low Smoke Zero Halogen (Lszh)(Iec 60332-1) Jacket. Certified Performance In A 4-Connector Configuration Upto 100 Mtrs Channel Requirements & Transmission Frequencies Up To 500 Mhz. Should Meet Ieee 802.3Af & Ieee 802.3At For Poe Applications. Cable Should Support Ethernet 10Gbase-T According To The Standards. In Existing Ms/Pvc Conduits/Casing Capping Including Making Connections To, Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Un-Armoured Copper Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With Electrolytic Grade Copper Made Of Copper Rods Confirming To Is 613-1964, Of Purity 99.7 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Reinforced Cement Concrete / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray (With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accredited Laboratory For Testing Procedure As Per Is:10810 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr.1.5 Sqmm 2 Core , Supply And Erection Of Galvanized Iron Pole With Galvanizing Done In Single Dipping (Average Coating Thickness Minimum 65 Microns) Continuously Tapered Poles Having Octagonal / Circular Crosssections Designed To Withstand The Maximum Wind Speed As Per Is 875, The Pole Shaft Shall Be Made From Sheet Steel (Ht Steel Conforming To Grade S355jo) And Confirming To Bsen 10025 And Shall Be Continuously Tapered With Single Longitudinal Welding. There Shall Not Be Any Circular Welding. The Welding Of Pole Shaft Shall Be Done By Submerged annual rate contract Welding (Saw) Process. Pole Shafts Shall Be Provided With The Rigid Flange Plate Of Suitable Thickness (Fe 410 Conforming To Is 226 / Is 2062) With Provision For Fixing 4 No. Foundation Bolts, This Base Plate Shall Be Fillet Welded To The Pole Shaft At Two Locations I.E. From Inside And Outside.The Octagonal Poles Shall Have Lockable Door Of Approximately 500 Mm Length At The Elevation Of 500 Mm From The Base Plate With Bakelite Sheet Having 6A Sp Mcb And 16 Sqmm Stud Type Connector ( 4 Nos) Inside The Pole At Door Opening For Cable Connection Of Following Length And Dimension As Per Table P-01 With Base Plate And Foundation Bolt On The Existing Cement Concrete Foundation.All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .9 Mtr , Providing And Laying Reinforced Cement Concrete Foundation For Octagonal / Conical Street Light Poles, High Mast Poles As Per Drawing Attach At Table P-4 With Following Procedure & All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr. , Providing, Installation, Testing And Commissioning Of Online Ups System, Single Phase 230 V, 50 Hz With 2 Hour Backup Smf Battery Bank As Per Specification 2 Kva , Supply Installation Testing and Commissioning of Intelligent Manageable Ethernet Switches Providing 24 X 10/100/1000 Fast Ethernet Ports- And 2 Dual Purpose Uplink (Provision For Copper / Fiber Giga Connectivity) With Lan Based Software. The Lan Based S/W Supports Enhanced Integrated Security, Including Network Admission Control (Nac), Advanced Quality Of Service (Qos), Availability And Scalable Management To Enable New Converged Applications, Supply Installation Testing and Commissioning of Battery Bank Comprising Smf/Vrla Batteries, Inter-Connection Wiring Etc. As Required Complete In All Respect. 12 V 42 Ah , Supply & Installation Of Ip-20 & Ik-08 , Ul Listed Wall Mounted Double Section Communication Enclosure (Rack) Made From Powder Coated (60 To 80 Micron) Crca Sheet, Front Sturdy Sheet Steel Frame Folded From One Piece And Welded With Minimum 5Mm Toughened Glass Door,Vertical Mounting Rail 1.6 Mm With Umarking , With All Round Protective Channel On The Door Aperture, Lock Integrated On Front Door, Top And Bottom Cover With Cable Entry Provision With Gland Plates, Integrated Side Walls, 2 Pair Of 19 Angles With Wall Mounting Provision On Wall. Accessories Like: 1 No Of 19 1U Horizontal Cable Manager, 1 No Of 90 Cfm 230V Ac Fan With 1 Mts Long Cable, Mounting Hardware , 1 No Of 19 1U, Mountable Socket Strips With 5 Nos Of 5A Universal Sockets With 2 Mts Long Power Chord For Supplying Power To Switches, Indicator, Molded Power Supply Cable. All As Per Pre Approved By Engineer In-Charge. 6 U Rack With Width 600 Mm & Depth 800 Mm , Supply, Drawing And Testing. Multi Mode (50/125 ?m) Glass Optic Fiber Cable, As Per Latest Amendments Of Tia/Eia 568/Iso/Iec 11801:2011/ Iec 60794-1-2 E1, E3,E11, F1/ En 50173-1/ En 187 000/ Iec 60974-2, 2-20, 2-21/ Itu G.652D, Cable Should Be Used For Lan And Wan Back Bones, . With Its Lszh Sheathing Should Be Ideal For Existing Ms/Pvc /Hdpe Conduits/ Slotted Channels For Identification Complete In All Respect. For Additional Technical Parameters Of Products/ Work , Refer Annexure A 6 Fiber , Supply, Installation, & Testing Of Indoor Duplex Singlemode Patch Cord (9/125 ?m (Os1/Os2) Made Of Glass Fiber Optic With Lszh Jacket, F8 2.0X4.1 Mm, Yellow, Singlemode G652.D (9/125 ?m (Os1, Os2) Mounted On Both Sides With St/E-2000/Sc/Mt-Rj/Pc Type Duplex Connectors In Acc. Iec 61754-20. Zirconia (Ceramic) Ferrule With A Pc Polished Endface Geometry, Connectors Should Be Tuned In Accordance With Iec 61753-1 For Category U (Uncontrolled Environment, Duplex Clip And White Plastic Dust Cover, Should Comply To Delta Il 0.2 Db After 500 Mating Cycles Coding And Lock Protection On Later Stage. Patch Cords Should Be Acc. To Iec 61753-1 (Table A.12) As Per Requirements. For Additional Technical Parameters Of Products/ Work , Supply, Installation, Testing & Commissioning Of 5 Mp Varifocal Bullet Network Camera Complete With All Required Specification And Supporting Accessories., 128Ch Network Video Recorder-Connect Up To 128 Ip Cameras, Dual Os, Up To 12 Megapixels Resolution, 1 Vga Output With Output Upto 1920×1080, Support H.265, Mjpeg, Supports N+1 Hot Spare System, Raid0, Raid1, Raid5, Raid6 And Raid10, Supports Hdd Hot Swap, Supports Dual Power-Redundant, Incoming Bandwidth 512 Mbps, 16 Sata Hard Disks, Anr Technology, 16 Sata Interfaces For 16 Hdds And Capacity Of Each Hdd Upto 8Tb, 4× Usb At Least 2 × Usb With 3.0, Alarm Installation Of 16/8, Rs-485, Rs232, 4 Rj-45 10 /100/1000 Mbps Self-Adaptive Ethernet Interface, Multiple Network Monitoring: Web Viewer, Ce, Fcc, Ul Certified , Maintenance Camera With Power Supply Per Month Per Camera (30 Camera X 1188 Per Month) , Installation Of Ofc Network Connectivity (One Time Coast) Per Node , Supplying And Fixing Of 4Tb Surveillance Hdd (Make- Toshbia, Seagate) , Supply Installation Testing and Commissioning of Network Switch With 4 Port Poe, 802.3Af Poe Ports , Suply And Fixing Of Junction Box,Spileter And Other Equipment , Wireless Mouse , Hdmi Cable 10 Mtr , Olt (Optical Line Terminal) , Onu ( Optical Network Units , Supply & Fixing Of Aluminum /Metal Junction Box For Bullet Camera: With Having Load Bearing Upto 3.0 Kg: Ip66 Protection &Operating Temp : 40C- 60C Approved Make : As Per Camera Oem
|