Circuit Breaker 2X100 - Bipolar Thermomagnetic Circuit Breaker, 100A Rated Current, Type C Trip Curve (Or Equivalent), Minimum Rated Voltage 220/380V, Frequency 50/60Hz, Minimum Interrupting Capacity 10Ka (Or Higher), For Mounting On Din Rail Or Appropriate Base., 2X32 Circuit Breaker - Bipolar Thermomagnetic Circuit Breaker, 32A Rated Current, 6Ka Minimum Interrupting Capacity, For Din Rail Mounting, 2X40 Circuit Breaker - Bipolar Thermomagnetic Circuit Breaker, 40A Rated Current, For Din Rail Mounting, 2X50 Circuit Breaker - Bipolar Thermomagnetic Circuit Breaker, 50A Rated Current, 2X70 Circuit Breaker - Bipolar Thermomagnetic Circuit Breaker, Rated Current Of 70A, Minimum Interrupting Capacity Of 6Ka (Or Higher), Din Rail Mounting, 3X32 Circuit Breaker - Tripolar Thermomagnetic Circuit Breaker, Minimum Rated Voltage Of 380/415V, 3X40 Circuit Breaker - Tripolar Thermomagnetic Circuit Breaker, 3X50 Circuit Breaker - Circuit Breaker Tripolar Thermomagnetic, Circuit Breaker 3X70 - Tripolar Thermomagnetic Circuit Breaker, Mounting On Din Rail, Circuit Breaker 3X100 - Tripolar Thermomagnetic Circuit Breaker, Mounting On Din Rail Or Appropriate Base., Circuit Breaker 3X150 - Thermomagnetic Circuit Breaker, Connection With Terminal For Cable Connection, Tripolar, Rated Current Of 150A, Capacity Minimum Interruption Of 10Ka (Or Higher)., Flexible Wire 16 Mm - Copper Electrical Conductor, Soft Temper, Stranding Class 5 (Flexible), Nominal Section Of 16 Mm², Flame-Resistant Pvc Insulation., Flexible Wire 10 Mm - Copper Electrical Conductor, Class 5 (Flexible), Nominal Section Of 10 Mm², Flexible Wire 06 Mm - Copper Electrical Conductor, Nominal Section 6 Mm², Flexible Wire 04 Mm - Copper Electrical Conductor, Nominal Section 4 Mm², Flexible Wire 2.5 Mm - Copper Electrical Conductor, Nominal Section 2.5 Mm², Flame-Resistant Pvc Insulation, Parallel Wire 2X2.5 Mm - Flexible Electrical Cable, Composed Of 2 Copper Conductors, 5 Mm² Each Way, With Flame-Resistant Pvc Insulation And External Pvc Cover, Parallel Cable Type (Double Insulation), Parallel Wire 2X4 Mm - Flexible Electrical Cable, Composed Of 4 Copper Conductors, Individual Flame-Resistant Pvc Insulation And External Pvc Cover, Wire Rigid Copper 1X50 - Unipolar Copper Electrical Conductor, Medium-Hard Or Hard Temper, Stranding Class 1 Or 2 (Rigid), Nominal Section Of 50 Mm², With Flame-Resistant Pvc Insulation, 4X50 Mm Aluminum Cable - Multiplexed Electrical Cable, Composed Of 4 Aluminum Conductors (Alloy 1350 Or Equivalent), With 3 Phases + 1 Neutral (Messenger), Nominal Section Of 50 Mm² Per Phase, With Insulation In Cross-Linked Polyethylene (Xlpe) Or Polyethylene (Pe) For 0.6/1 Kv, Suitable For Aerial Distribution Networks, With Neutral Conductor With Mechanical Support Function, 4X32 Mm Aluminum Cable - Multiplexed Electrical Cable, Composed Of 4 Aluminum Conductors, With 3 Phases + 1 Messenger Neutral, Nominal Section Of 32 Mm² Per Phase, Insulation In Multiplexed, Consisting Of 3 Aluminum Conductors (Phases), Nominal Section Of 50 Mm² Each, With Insulation In Multiplexed Electrical Abo, Nominal Section Of 25 Mm² Each, For Overhead Networks, 20 Amp Overlay Socket - Overlay Electrical Socket
|