1.1 Full Site Civil Engineer With Additional Charges, 2.1 Supply And Installation Of Site Board With Galvanized Sheet And Wooden Structure. Af_03/2022_Ps, 3.1 Demolition Of Ceramic Coating, Manually, Without Reuse. Af_09/2023, 3.2 Removal Of Doors, 3.3 Removal Of Crockery, 3.4 Removal Of Wooden Flooring (Floor And Joist), 3.5 Removal Of Electrical Cables, With A Section Of Up To 2.5 Mm², 3.6 Removal Of Electrical Cables, With A Section Greater Than 2.5 Mm² And Less Than 10 Mm², No Reuse.Af_09/2023, 3.7 Removal Of Electrical Switches/Sockets, 3.8 Demolition Of Solid Brick Masonry, 3.9 Removal Of Light Fixtures, 3.10 Demolition Of Reinforced Concrete Slabs, Mechanized Using A Hammer, 3.11 Removal Of Roof Tiles Metallic And Ceramic Fiber Cement, 3.12 Removal Of Wooden Scissors, With A Gap Greater Than Or Equal To 8M, 4.1 Plaster Or Single Putty In 1:2:8 Mortar Mix, Manual Preparation, Manually Applied To Blind Facade Panels (Without The Presence Of Gaps), 25 Mm Thick. Af_09/2022, 4.2 Plating Applied To Masonry (With The Presence Of Gaps) And Concrete Facade Structures, Using A Trowel. Mortar Mix 1:3 Prepared In A 400L Concrete Mixer. Af_10/2022, 4.3 Surface Waterproofing With Asphalt Blanket, Two Layers, Including Application Of Asphalt Primer, E=3Mm Ee=4Mm. Af_09/2023, 4.4 Manual Excavation For Baldrame Beam Or Footing (Including Excavation For Placing Formwork). Af_01/2024, 4.5 Unidirectional Precast Slab, Double Supported, Ceramic Filling, Trussed Beam, Total Slab Height (Filling+Cover) = (8+4). Af_11/2020, 4.6 Unidirectional Precast Slab, For Ceiling, Conventional Joist, Total Slab Height (Filling+Cover) = (8+3). Af_11/2020, 4.7 Pillar Or Beam Frame Of Conventional Reinforced Concrete Structure Using 10.0 Mm Ca-50 Steel - Assembly. Af_06/2022, 4.8 Concreting Of Beams And Slabs, Fck=25 Mpa, For Precast Slabs Using A Pump - Laying, Thickening And Finishing. Af_02/2022_Ps, 4.9 Assembly And Disassembly Of Formwork For Rectangular Pillars And Similar Structures, Simple Right Foot, Made Of Plasticized Plywood Sheet, 10 Uses. Af_09/2020, 4.10 Insulated Shoe Frame, Baldrame Beam And Running Shoe Using 10 Mm Ca-50 Steel - Assembly. Af_01/2024, 4.11 Subfloor In Ready-Made Mortar, Applied In Dry Areas On Slabs, Not Adhered, Non-Reinforced Finish, Thickness 4Cm. Af_07/2021, 5.1 Wall With Plasterboard System For Drywall, Internal Use With A Single Side And A Double Side And Metal Structure With Double Guides, Without Gaps. Af_07/2023_Ps, 5.2 Installation Of Glass Wool Insulation On Drywall Walls. Af_07/2023, 5.3 Acrylic Texture, Manual Application To Wall, One Coat. Af_04/2023, 6.1 Ceramic Floor Covering With Porcelain Type Plates Of Dimensions 60X60 Cm Applied In Environments With An Area Between 5 M² And 10 M². Af_02/2023_Pe, 6.2 Ceramic Coating For Internal Walls With Enamelled Plates Of Dimensions 33X45 Cm Applied To The Entire Height Of The Walls. Af_02/2023_Pe, 6.3 Ceramic Skirting Board 7Cm High With Enamelled Plates Dimensions 60X60cm. Af_02/2023, 7.1 Wooden Door Kit For Painting, Semi-Hollow (Light Or Medium), Medium Standard, 80X210cm, Thickness Of 3.5Cm, Included Items: Hinges, Assembly And Installation Of The Stop, Lock With Hole Execution - Supply And Installation. Af_12/2019, 7.2 Wooden Door Kit For Painting, 70X210cm, 7.3 Opening Aluminum Door With Lamb
|