|
Supply And Installation Of Construction Plate With Galvanized Sheet And Wooden Structure. Af_03/2022_Ps, Emergency Light, With 30 2 W Led Bulbs, Without Ballast - Supply And Installation. Af_09/2024, Set For 3/4 (20Mm) Condulet With One (1) Standard Socket, Three (3) Poles, Current 10A, Voltage 250V, (2P+T/10A- 250V) And One (1) Station Plate, Including Supply, Installation, Support, Module And Plate, Exclusive Condulet, Condulet Pvc, Type C, For Weldable Pvc Conduit Dn 25 Mm (3/4), Apparent - Supply And Installation. Af_01/2026, Rigid Weldable Conduit, Pvc, Dn 25 Mm (3/4), Set Consisting Of 3 Insulated Flexible Copper Cables, Both With Cross Section Of 2.5 Mm², Anti-Flame 450/750 V, For Terminal Circuits - Supply And Installation., Photoluminescent Plate For Emergency Signaling, Type P1, Diameter 300Mm, Including Fixing, Type P2, Type A2, Base Dimension 300Mm, Additional Emergency Signage Plate With Danger Writing, Flammable, No Smoking With Letters At Minimum 50Mm Height, Type S2-D, Dimension (380X190)Mm, Type S2-E, Type S3, Type S12, Type E1, Dimension (300X300)Mm, Type E2, Dimension (150X100)Mm, Type E3, Type E5, Dimension (400X400)Mm, Type E10, Type E12, Installed On Floor, Dimension (100X100)Cm, Type M1, Dimension (400X600)Mm, Type M2, Fire Extinguisher Portable Fire With A Load Of 6 Kg, Class Bc - Supply And Installation. Af_01/2026_Pe, Shelter For Fire Extinguisher Ch18 60X40x30 Cm, Lightweight Galvanized Steel Conduit, 25Mm Diameter (1), Apparent Installation Or On Ceiling With Metal Wedge Clamp, Type D, Including Accessories For Fixing And Connections, Painting With Alkyd Base And Finish Paint (Enamel Synthetic Graphite) Sprayed On Metallic Surfaces (Except Profile) Executed On Site (By Coat). Af_01/2020_Pe, Painting With Alkyd Finishing Paint (Matte Synthetic Enamel) Sprayed On Metallic Surfaces (Except Profile) Executed On Site (02 Coats). Af_01/2020_Pe, Aluminum Conduit, Type B, For Galvanized Steel Conduit Dn 25 Mm (1), Set For 1 Conduit (25Mm) With One (1) Parallel Switch, (10A-250V) And One (1) Station Board, Addressable Fire Alarm Control Panel For 24 Loops, Including Supply And Installation, Exclusive 4-Way Cable For Alarm, Manual Fire Alarm Activator, Insulated Flexible Copper Cable, 1, For Terminal Circuits - Supply And Installation. Af_03/2023, Audible And Visual Warning, 2, Demolition Of Concrete Sidewalk Or Slab With Electrical Equipment, Manual Loading Of Material Of Any Nature On Truck, Exclusive Transport, Transport Of Demolished Material In Bucket, Exclusive Of Manual Or Mechanical Loading, Complete Booster Hydrant In Masonry Box, Thin Concrete Ballast, Applied To Floors, Slabs On Ground Or Radiers, 3 Cm Thick. Af_01/2024, Demolition Of Masonry For Any Type Of Block, Mechanized, Without Reuse. Af_09/2023, Manual Backfilling Of Trench, Including Spreading And Manual Compaction With Socket, Mortar Ratio 1:4 (In Volume Of Cement And Medium Wet Sand) With Addition Of Waterproofing Agent, Mechanical Preparation With 300 Kg Horizontal Shaft Mixer. Af_08/2019, Tightness Test On Hydrant Pipe With Emission Of Report, Easel Kit For Gas Installation, Included Records, Pig Tail, Pressure Gauge And Installation, Tube, Pex, Multilayer, Dn 20, Installed In Installation Of Gas Installations
|