Curved Arm With Shoe Specification: Curved Arm Length 1.5 Mt (150Cm). Manufactured In Steel Tube With A Minimum Thickness Of 48 Mm And Shoe. Distance Between Holes In The Shoe: 20 Cm For Fixing To Steel Plate U Beam. Finish: Hot-Dip Galvanized In Accordance With Standard Nbr 6323. Function: Support The Luminaire., Curved Arm With Shoe 3.00 Mt Specification: Curved Arm Length Of 3.00 Mt Mt (300Cm). Manufactured In Steel Tube With A Minimum Thickness Of 48 Mm And Shoe. Distance Between Holes In The Shoe: 20 Cm For Fixing To Steel Plate U Beam. Finish: Hot-Dip Galvanized In Accordance With Standard Nbr 6323. Function: Support The Luminaire., Pp Cable 2 10 Mm, 10 Mm Aluminum Quadruplex Cable, 16 Mm Aluminum Quadruplex Cable, 25 Mm Aluminum Quadruplex Cable, 50 Mm Aluminum Quadruplex Cable, 70 Mm Aluminum Quadruplex Cable, 90 Mm Aluminum Quadruplex Cable, 70 Piercing Connector; Specification: Perforating Derivation Connector 70Mm (10-70Mm² Specification: Perforating Derivation Connector 120Mm (16-120Mm² Cdp 120., Perforating Connector 150: Specification: Perforating Derivation Connector 150Mm (35-150Mm² Cdp 150., Extendable Ladder 7, 80 Meters Specification: Extendable Ladder, Made Of Fiber Glass, Measuring A Minimum Of 4.50 M In Height Closed And 7.80 M In Height Open With A Minimum Of 25 Steps, Steps In Aluminum Alloy, With Non-Slip Moldings, Ratchet In Aluminum Alloy, Backrest In Nylon Strap Covered In Vulcanized Rubber, Manual Movable Lance Actuation By Pulley And Rope System., Extendable Ladder 10, 20 Meters Specification: Extendable Ladder, Measuring A Minimum Of 5.70 M In Height Closed And 10. 20 M In Height Open With A Minimum Of 33 Steps, High Fusion Tape: Specification: High Fusion Insulating Tape 20Mt, 3Mm, Color: Black, Insulating Tape 20 Mts: Specification: Insulating Tape, 18Mm With Anti-Uv Epoxy Or Polyester Electrostatic Powder Painting;3) Lenses: In Polymethyl Methyl Methacrylate (Pmma) Or Polycarbonate Or In Tempered Glass, In Compliance With Procel Guidelines;4) Minimum Effective Luminous Flux Of 11,000Lm With Supporting Report; 5) Color Rendering Index 70 Or Greater; 6) Classification Regarding Luminous Intensity Distribution (Item 4.3.3. Of Nbr 5101:2012) As Limited (Cut-Off) Or Totally Limited (Fullcut-Off), Type Ii, Short With Greater Intensity In The Minimum Gamma Of 62°À 65°; 7) Power Supplies/Drivers With Minimum Degree Of Protection Ip-66, Power Supply Between 90 - 305 Vac Or Higher Variation Range, Frequency 50/60Hz, Isolation Class I, Minimum Power Factor (0.92), Total Harmonic Distortion (Thd) Of Current Less Than 15%, Immunity Against Transient Overvoltages According To Iec 61000-4-4 And Iec 61000-4-5; 8) 10Ka Auxiliary Surge Suppressor Installed Separately And Fixed To The Internal Part Of The Luminaire For Protection Against Atmospheric Discharges And Electrical System Maneuvers; 9) Luminaire Tested And Certified With The Following Requirements: Nbr Iec 60598-1/10 - Luminaires - Part 1: Requirements
|