|
Bids Are invited for Custom Bid For Services - Hydrotesting And Ndt Of Lpg Storage Vessels At Nasik Lpg Plant - Depressurization And Degassing Msv (2 X 500 Mt Bullets ). , Depressurization And Degassing Of Bullets- Above Ground Bullets- 90 Mt , Depressurization And Degassing Of Bullets- Above Ground Bullets- 150 Mt . , 2X 500 Mt Msv. Disconnecting The Inlet, Outlet Of The Lpg Liquid And Vapors Line, Srv, Hla, Manhole, Water Drain Line, Globe Valves, Rov And Other Fittings Of The Bullets , 90 Mt Agb- Disconnecting The Inlet, Outlet Of The Lpg Liquid And Vapors Line, Srv, Hla, Manhole, Water Drain Line, Globe Valves, Rov And Other Fittings Of The Bullets , 150 Mt Agb- Disconnecting The Inlet, Outlet Of The Lpg Liquid And Vapors Line, Srv, Hla, Manhole, Water Drain Line, Globe Valves, Rov And Other Fittings Of The Bullets. , Providing Ms Tubular Ladder/Scaffolding Inside The 2 X 500 Mt Msv Bullet , Providing Ms Tubular Ladder/Scaffolding For The 90 Mt Above Ground Bullet , Providing Ms Tubular Ladder/Scaffolding For The 150 Mt Above Ground Bullet , Thorough Cleaning Of The Inner Surface Of 2 X 500 Mt Msv , Thorough Cleaning Of The Inner Surface Of 90 Mt Above Ground Bullet , Thorough Cleaning Of The Inner Surface Of 150 Mt Above Ground Bullets , Fixing Back All Fittings For 2X500 Mt Msv , Fixing Back All Fittings For 90Mt Above Ground Bullet , Fixing Back All Fittings For 150Mt Above Ground Bullet , Visual Inspection Of Lpg Storage Vessels , Ultrasonic Thickness Measurement Of 2X500 Mt Msv , Ultrasonic Thickness Measurement Of 90 Mt Above Ground Bullet: , Ultrasonic Thickness Measurement Of 150 Mt Above Ground Bullet: , Ultrasonic Gauzing Of Nozzle Neck , Hardness Testing Of 2X500mt Msv: , Hardness Testing Of 90Mt Above Ground Bullet: , Hardness Testing Of 150Mt Above Ground Bullet: , Wet Fluorescent Magnetic Particle Test Of 2X500mt Msv , Wet Fluorescent Magnetic Particle Test Of 90Mt Above Ground Bullet , Wet Fluorescent Magnetic Particle Test Of 150Mt Above Ground Bullet , Ultrasonic Flaw Detection Test Of 2X500mt Msv: , Ultrasonic Flaw Detection Test Of 90Mt Above Ground Bullet: , Ultrasonic Flaw Detection Test Of 150Mt Above Ground Bullet: , Dye Penetration Test , Checking Of Settlement Of 2 X 500 Mt Msv And 2 X 150 & 1 X 90 Mt Above Ground Bullets , Wet Calibration For Each Bullets-(2X500 Mt Msv And 1X90 Mt + 2X150mt Above Ground Bullets). , Hydro Test And Stretch Test – Pressure Testing Of The 2X500mt Msv , Hydro Test And Stretch Test – Pressure Testing Of The 90Mt Above Ground Bullet , Hydro Test And Stretch Test – Pressure Testing Of The 150Mt Above Ground Bullet , Certification And Documentation For (2 X 500 Mt Msv And 2 X 150 Mt & 1 X 90 Mt Above Ground ) Lpg Bullets: , Supply And Installtion Of Ht Full Thread Astm A193, Grade B7 Stud , Supply Of Spiral Bound Stainless Steel (Aisi 304) , Health Check-Up For Cp System For 2 X 500 Mt Msv. , Hydrotesting Of All Lpg Pipeline Upto 3 K.M. : , Hydrotesting Of Hydrant/Air/Service Water Pipeline Upto 2.5 Km : , Periodic Testing Of Fire Water Storage Tanks 2X 3771 Kl : , Painting Of Exposed Area Of Vessels-(2X500 Mt Msv And 1X90 Mt + 2X150mt Above Ground Bullets)
|