The Device Is Intended For Use As An Embolic Protection System To Contain And Remove Embolic Material (Thrombus/Debris) During Angioplasty, Stenting, Or Thrombectomy Procedures In The Coronary, Peripheral, And Carotid Arteries. Features A Braided Nitinol Filter With Heparin Coating. Compatible With 0.014-0.018 Micro Conductor. Filter Diameters Ranging From 3 To 7 Mm In 9 Different Models (Including Half Models) Provide Less Vascular Irritation And Improved Capture Efficiency. Gradual Change In Hole Size, Well Balanced Density. Using A Unique Weaving Technology, The Mesh Naturally Adheres To The Vessel Wall. Minimum Compatibility With 6F Catheter., Dura Substitute (Various Sizes), Balloon Catheter For Transluminal Angioplasty Of High-Pressure Coronary Arteries. Cylinder Material And Cylinder Structure: Three-Layer - Elastomer/Nylon/Elastomer. Balloon Diameter (Mm): 2.00; 2.25; 2.5; 2.75; 3.0; 3.25; 3.5; 3.75; 4.0; 4.5; 5.0. Length: 6, 8, 12, 15, 20, 25, 30 Mm. Hydrophilic M-Coating For Distal 32 Cm. Lack Of Hydrophilic Coating On Cylinders 6 And 8 Mm Long. 2 X-Ray Contrast Markers. Distal Balloon Profile 0.036. Distal Tip With Profile 0.42Mm And Length 2.9Mm. Quick Change Balloon For Guidewire 0.014. The Working Length Of The Catheter Is At Least 145 Cm. The Diameter Of The Proximal Shaft Is 1.9 Fr, The Distal Shaft Is 2.6 Fr. Nominal Pressure 12 Atm. Burst Pressure 22 Atm (For Cylinders With A Diameter Of 2.00-4.00) And 20 Atm. (For Cylinders With A Diameter Of 4.50-5.00). The Balloon Design Is Three-Leaf With Short Arms Of 3 Mm. Thin And Short Radiopaque Marks 0.8 Mm Long And 25 Microns Thick. A Short Stainless Steel Stylet In The Middle Shaft To Strengthen The Exit Port For The Guide And Prevent Kinks, To Ensure The Transfer Of Pushing Force From The Proximal To The Distal Segment Of The Catheter., 11G 5 Tapered Bevel Needle; Size 13G, 5 Inches, Perfect Matching Of Mandrin And Trocar Eliminates Blockage Of The Latter • Tetrahedral And Beveled Mandrins Are Interchangeable • Standard Caliber 10G (3.4 Mm), 11G (3.05 Mm), 13G (2.41 Mm) - Length 12.7 Cm. • 10G Caliber Also Available With A Length Of 22.9 Cm. • Color Marking Of Mandrin And Trocar, The Kit Is Intended For Percutaneous Vertebroplasty In The Treatment Of Vertebral Tumors, Compression Fractures Of Vertebral Bodies Due To Osteoporosis., Non-Adhesive Radiopaque Dmso-Soluble Implant For Embolization Of Pathological Changes Of Various Locations, Complete With Syringes. Density Index – 18, 20, 34, 34L. The System Includes An Ampoule With 1.5 Ml Of Embolic Agent, An Ampoule With 1.5 Ml Of Dmso Solvent, 3 Syringes With A Volume Of 1 Ml., Medium Viscosity Bone Cement With Gentamicin (40G), Surgical Biological Glue, Syringe 5Ml, Protective Covers (5 Pieces Per Pack) Protective Covers For Zeiss Operating Microscope, Mri-Compatible Dual-Chamber Icd, Improved Functionality, With Diagnostics Of Atrial Potentials, Complete With Accessories, Mri-Compatible Three-Chamber Icd Of The 7Th Series With Increased Functionality With An Automatic Mri Sensor, With Improved Support For Remote Monitoring, With Rapid Device Interrogation And With A Physiological Frequency Adaptation Sensor That Simulates The Functioning Of A Healthy Sinus Node, Locking Screw – The Screw Is Designed To Clamp The Rod In The Head Of The Pedicle Screw. The Screw Diameter Is 6.4 Mm, The Special Trapezoidal Asymmetrical Thread With A Diameter Of S6.4X1 Mm Ensures High Strength And Prevents Thread Distortion. The Sheared Thread Profile Prevents Extension Of The Head Arms By Directing Reaction Forces Into The Screw., Implantable Cardioverter-Defibrillator With Cardiac Resynchronization Therapy Function, Mri-Compatible With Accessories, Precurved Rod For Percutaneous Fixation With A Diameter Of 6.0 Mm, Length 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 110, 120, 130,140, 150, 160, 170, 180, 190, 200 Mm, Polyaxial Cannulated Fenestrated Screw, Diameter 4.5, 5.0, 5.5, 6.0, 6.5, 7.0, 7.5, 8.5, 9.5, 10.5, Length 30, 35, 40, 45, 50.55, 60, 65, 70, 75, 80, 85.90 Mm, The Screw Is Designed To Clamp The Rod In The Head Of The Pedicle Screw. The Screw Diameter Is 10.1 Mm, The Special Trapezoidal Asymmetrical Thread With A Diameter Of 10.1 Mm Provides High Strength And Prevents Thread Distortion. The Sheared Thread Profile Prevents Extension Of The Head Arms By Directing Reaction Forces Into The Screw. The Screw Height Is 5.5 Mm, The Screw Is Cannulated., Transpedicular Screws Are Polyaxial, Self-Tapping, Cylindrical In Shape Along The Entire Length Of The Outer Diameter, The Thread On The Rod Is Conical, The Outer Thread Diameter Is Constant. Threads With A Diameter Of 3.5, 4.0, 4.5 Mm, Length 10, 12, 14, 16, 18, 20, 22, 24, 26, 28, 30, 32, 34, 36, 38, 40 Mm. The Thread On The Screw Is Complete., Powder Of Plant Origin For Hemostasis And The Formation Of An Anti-Adhesive (Anti-Adhesive) Barrier, 3G, Individual Procedural Kit For Coronary Angiography And Stenting, Universal, Cement - Represents 2 Sterilely Packaged Components: One Component: An Ampoule Containing A Colorless Liquid Monomer With A Sweet And Sour Odor 1/2 Dose Of 9.5 Ml Of The Following Composition: - Methyl Methacrylate (Monomer) - 9.40 Ml. -N,N-Dimethylparatoluidine - 0.10 Ml. -Hydroquinone Usp- 0.75 Mg.
|