Bids Are invited for Facility Management Services - Lumpsum Based - Industrial; Biennium Service Contract For Maintenance Of Mm Equipments, Preservation Etc For Hrsg And Bop Area At Rgppl; Consumables To Be Provided By Service Provider (Inclusive In Contract Cost) - Pm Of Chemical Dosing Pumps (Positive Displacement) =10 Kw , Pm Of Pumps Of Rating = 15 Kw , Pm Of Pumps Of Rating> 15 Kw & = 30 Kw Rating , Pm Of Pumps Of Rating> 30 Kw & ? 75 Kw Rating , Pm Of Pumps Of Rating> 75 Kw & = 200 Kw Rating , Pm Of Pumps Of Rating> 200 Kw , Pump/ Valve Gland Packing Replacement/ Adjustment , Decoupling & Coupling/ Spider Replacement Of Pump/Fan/Blower/Compressor , Alignment Of Pump/Fan/Blower/Compressor , Mechanical Seal Adjustment/Replacement Of Pump , Pm Of Cooling Tower Fans (10 Mtr Fan Dia) , Pm Of Air Compressor Zt 90/110/Ga 15/18 , Pm Of Travelling Water Screens (Intake) , Pm Of Fans/ Air Blower ? 15 Kw Rating , Pm Of Fans/ Air Blower > 15 Kw Rating , Pm Of Mixers/ Agitators , Pm Of Compressor Air Dryer , Pm Of Valve Of ? 80 Nb Size , Pm Of Valve Of > 80 Nb & ? 150 Nb Size , Pm Of Valve Of > 150 Nb Size & ? 250 Nb Size , Pm Of Valve Of > 250 Nb Size & ? 500 Nb Size , Pm Of Valve Of > 500 Nb Size , Pm Of Gearboxes Of Valves , Trash Screen Cleaning Of Ct Bd/ Ct Cw/ Inatke Pumps , Minor Bd Works Of Chemical Dosing Pumps =10 Kw (Without Dismantling/ Partial Dismantling) , Minor Bd Works Of Pump Rating = 15 Kw(Without Dismantling/ Partial Dismantling) , Minor Bd Works Of Pump Rating > 10 Kw & ? 30 Kw (Without Dismantling/ Partial Dismantling) , Minor Bd Works Of Pump Rating > 30 Kw & ? 75 Kw (Without Dismantling/ Partial Dismantling) , Minor Bd Works Of Pump Rating > 75 Kw & ? 200 Kw(Without Dismantling/ Partial Dismantling) , Minor Bd Works Of Pump Rating > 200 Kw(Without Dismantling/ Partial Dismantling) , Minor Bd Works Of Cooling Tower Fans (10 Mtr Fan Dia) And/Or Gearbox (Without Dismantling , Minor Bd Works Of Air Compressor Zt 90/110/ Ga 15/18 (Without Dismantling/ Partial Dismantling) , Minor Breakdown Works Of Fans/ Air Blower ? 15 Kw Rating (Without Dismantling/ Partial Dismantling) , Minor Bd Works Of Fans/ Air Blower > 15 Kw Rating (Without Dismantling/ Partial Dismantling) , Minor Bd Works Of Gear Box (Without Dismantling/ Partial Dismantling) , Minor Bd Works Of Pulley Belts Chain (Without Dismantling/ Partial Dismantling) , Routine Maintenance Of Instrument Air Dryer (Without Dismantling/ Partial Dismantling) , Balancing Work Of Pumps, Fans, Blowers (Without Dismantling/ Partial Dismantling) , Minor Bd Works Of Mixers/ Agitators (Without Dismantling/ Partial Dismantling) , Oil Top Up/ Greasing Per Equipment , Routine Maintenance Of Valves (With/ Without Actuator) Class Upto 3000 Size ? 80 Nb , Routine Maintenance Of Valves (With/ Without Actuator) Class Upto 3000 Size > 80 Nb & ? 150 Nb , Routine Maintenance Of Valves (With/ Without Actuator) Class Upto 3000 Size > 150 Nb & ? 250 Nb , Routine Maintenance Of Valves (With/ Without Actuator) Class Upto 3000 Size > 250 Nb & ? 500 Nb , Routine Maintenance Of Valves (With/ Without Actuator) Class Upto 3000 Size > 500 Nb , Setting Of Deluge Valves Spray Nozzle Replacement (Fire Protection) , Safety Shower/Eye Washer Maintenance , Valve Actuator/ Gear Box Servicing , Ct Hot Basin Cleaning Distribution Valve Servicing (Each Cell) , Y Strainer/Cyclone Separator/Single Cartridge Element Or Filter Cleaning /Replacement , Suction Strainer Cleaning For Pipe Size Up To 12 , Suction Strainer Cleaning For Pipe Size More Than 20 , Cartridge Filter Replacement (In Set Of 10 Nos In Each Opn.) , Repair & Maintenance Of Piping/Structural Works As Per Work Specification , Replacement/New Fabrication Of Piping Upto 80Nb As Per Work Specification(=1 Mtr Length Each Work) , Replacement/New Fabrication Of Piping > 80Nb As Per Work Specification(=1 Mtr Length Each Work) , Replacement/New Fabrication Of Structural Parts As Per Work Specification (Upto100 Kg For Each Work) , Erection/Dismantling Of Scaffolding Work As Per Work Specification , Application Of Sealants/Leak Arresting Compounds/Wraps , Replacement Of Gaskets For Flange Size ?100 Nb , Replacement Of Gaskets For Flange Size >100 Nb?300 Nb , Replacement Of Gaskets For Flange Size >300 Nb , Tightening Of Bolts For Flanged Joints , Fixing/Dismantling Of Unloading Hoses For Tankers , New Fabrication /Erection Of Structures Metal Work Piping Including Cutting/Welding Work , Laying/Dismantling Of Temporary Pipes(With Available Materials) , Coupling And Decoupling Of Valves , Installation/ Maintenance Of Level Gauge , New Installation/ Replacement Of Threaded Pipe Fittings(Elbow Nipple Unions Etc.) Upto 3 Inch. , New Installation/ Replacement Of Pvc/ Cpvc Pipe And Fittings= 3 Inch. , New Installation/ Replacement Of Pvc/ Cpvc Pipe And Fittings Of Size >3 Inch And = 6 Inch. , New Installation/ Replacement Of Pvc/ Cpvc Pipe And Fittings Of Size >6 Inch And = 12 Inch. , Repairing Of Hdpe Pipe Line Size Upto 100Nb As Per Work Specification , Repairing Of Hdpe Pipe Line Size >100 Nb?450 Nb As Per Work Specification , Repairing Of Hdpe Pipe Line Size Above 450 Nb And Upto 860 Mm As Per Work Specification , Pump Major Oh/ Replacement Of = 15 Kw Rating , Pump Major Oh/ Replacement Of >15 Kw And = 30 Kw Rating , Pump Major Oh/ Replacement Of > 30 Kw And = 75 Kw Rating , Pump Major Oh/ Replacement Of > 75 Kw & ? 200 Kw Rating , Pump Major Oh/ Replacement Of > 200 Kw Rating , Major Replacement Of Inlet/ Outlet Expansion Bellow Size Up To 300Mm , Major Replacement Of Inlet/ Outlet Expansion Bellow Size Up > 300Mm , Major Oh/ Replacement Of Cooling Tower Fans & Gearbox Replacement/ Maintenance , Major Oh/ Replacement Of Fans/ Air Blower ? 15 Kw Rating , Major Oh/ Replacement Of Fans/ Air Blower > 15 Kw Rating , Major Oh/ Replacement Of Air Compressor Zt 90/110/ Ga 15/18 , Major Oh/ Replacement Of Travelling Water Screens , Major Oh/ Replacement Of Air Dryer Maintenance Including Alumina Replacement , Major Oh/ Replacement Of ? 80 Nb Size , Major Oh/ Replacement Of > 80 Nb & ? 150 Nb Size , Major Oh/ Replacement Of > 150 Nb Size & ? 250 Nb Size , Major Oh/ Replacement Of > 250 Nb Size & ? 500 Nb Size , Major Oh/ Replacement Of > 500 Nb Size , Inspection Repair Replacement Of Hrsg Pipe Penetration Bellows Expansion Joints , Manhole/Inspection Access Opening Inspection Assistance Closer Of Manholes Above 500Mm Dia Opening , Dewatering Cleaning Removal Of Sludges , Internal Cleaning Of Tanks- Capacity 48000 M³( Fost & Fnst- Water Storage Tanks , Internal Cleaning Of Tanks-Capacity 8000 M³( Rwst,Neutralization Tank,Fwst,Dm Water Tank,Swro Plant , Material Handling (Shifting From One Location To Other Location ?1000 Kg Each Time) , Installation Of Dewatering Pumps/ Sump Pumps As Per Instruction Of Eic , Support Services For Colony/ Incinerator Maintenance , Assistance/ Support Services During Inspection & Maintenance Of Equipments Like Bfp Cw Pumps , Assistance / Support Services For Hrsg During Unit Startup/ Shutdown , Assistance/ Support Services As Per Work Specification , Desilting Of Intake Well And Pump Suction Basin , Hrsg Internal Floor Cleaning & Inspection , Hrsg Drum Internal Cleaning & Inspection , Hand Rotation Of Rotor & Freeness Checking Of Pumps/Fan/Blower Of All Size , Preventive Maintenance/ Filters Cleaning Of Preservation Dehumidifiers In Hrsg , Maintenance Of Preservation Dehumidifiers In Hrsg , Inspection Repair Replacement Any Parts Of Hrsg Internals Hydro Testing Of Hrsgs Liasoning With , Oil Wear Debris Analysis , Tube Leak Repair Valve Replacement Of High Pressure (Hrsg)With Ibr Quality Weld For <80Nb Size Pipe , Radiography/ Paut Testing Of High Pressure Weld Joints , Replacement Of High Pressure(Hrsg) Bfp Recirculation Valve Of Size 3 To 4: Nb With Ibr Quality Weld , Replacement Of High Pressure(Hrsg) Bfp Discharge Nrv/Drum Level Control Valves With Ibr Quality Weld , Phe Complete Cleaning By Removing Plates , Ct Splash Bar & Drift Eliminator Repair/Replacement , Freeness Checking/Greasing Of All Hrsg Valves Supports During Shut Down
|