Construction Of A Section Of The Overhead Street Lighting Network Of A District Road (According To The Documentation, Poles No. 88/5 To 86/15), Powered From The Existing Pole No. 86/4, With Asxsn 2X25 Mm2 Cable, Suspended On 9 Spun Poles, 10.5 M High And 2 9 M High Poles, Placed Directly In The Ground With Footing Plates, Approx. 518/539 M. A Lightning Arrester Should Be Installed On The 86/15 Pole And Grounding ≤ 10 Ω Should Be Performed. A Set For Portable Earthing Devices Should Be Installed On The Last Pole. Led Luminaires With A Luminous Flux Of Min. 9300 Lm, Mounted On Wo-1 Tubular Booms. Two-Chamber Led Road Luminaires With Factory-Installed Nema 5/7 Pin Sockets And Lighting Controllers. The Marking Of The Poles Should Be Agreed With The Investor. The Lighting Control Must Be Compatible With The Existing System Used In The Kolbuszowa Commune. The Existing System Is Maintained By Isc Sp. Z O. O., Ul. Krakowska 140A, 34-120 Andrychów. Before Starting The Work, The Scope And Date Of The Work Should Be Agreed With The Property Owners. This Is A Continuation Of The Existing Lighting, The Shape Of The Luminaires Should Be Matched To The Existing Ones. The Conditions Set Out In The Contract With Zdp In Kolbuszowa (Decision No. 70) Must Be Fulfilled. The Task Must Be Submitted For Acceptance To Pge Dystrybucja Rejon Energetyczny Mielec And Completed With Positive Acceptance. Minimum Requirements For Led Luminaires.1) Two-Chamber Housing Made Of Die-Cast Aluminum, Tempered Glass With A Self-Cleaning, Scratch-Resistant Coating2) Powder-Coated Body With Electrostatic Coating,3) Luminaire Made In Class Ii Anti-Shock Protection6) Housing And Accessories Chamber With Ip 66 Tightness, Must Include A Pressure Equalizing Filter, 7) Impact Resistance - Ik 088) Color Temperature Of The Diodes Used In The Range Of 3800K - 4200K 9) Power Supply System Of The Luminaire Enabling Control Of An Analog Signal 0 -10 V 10) Power (Flux) Reduction Must Be Carried Out Smoothly By Reducing The Luminous Flux Of All Led Sources Simultaneously And Not By Turning Off Individual Led Panels In One Luminaire 11) Luminous Efficiency Of The Luminaire (Taking Into Account All Losses) Min. 170 Lm/W12) Power Factor (Cos Φ)≥0.98 For The Rated Power, Maintaining The Power Factor Cos Φ Above 0.96 When Controlling The Luminaire In The Range Of 20-100% Of The Rated Power13) Resistance Of The Luminaire To Overvoltages: 10 Kv.14) The Luminaires Hook Should Be An Integral Part Of The Luminaire And Be Able To Be Mounted Directly On Lighting Poles Without An Additional Adapter, Tilt Angle Adjustment In The Range Of -150 To +150, In Steps Of 50 15) The Luminaire Is Equipped With A Factory-Installed Nema 5/7Pin Socket, 16) It Has Valid Certificates: Ce, Rohs, Enec, Enec+17) Warranty Min. 5 Years (60 Months) From The Date Of Acceptance Of The Works. Note: If The Swz Or Annexes To The Swz, Including Design Documentation Or Technical Specifications For The Execution And Acceptance Of Works, Would
Contact Information
Address
Gmina Kolbuszowa,Kolbuszowa,36-100,Podkarpackie,Pl823 - Rzeszowski
Email
zamowienia.publiczne@ekolbuszowa.pl
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 113148165
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.