Bids Are invited for Provn Of Solar Power Plant Factor Of Capacity 0 Point 6 Mwp Supply Of Power Distribution Panel 400A, 415V. The Panel Indoor Type Floor Mounted And Free Standing Designed For Ip-4X Ingress Protection, Made Of Crca Sheet Steel. - The Enclosure Shall Have Sturdy Support Structure With Angle Supports As Necessary. Enclosure Shall Be Finished With Powder Coating, After Finishing 10 Tanks Chemical Treatment. Paint Shed Shall Be Ral-7035. Suitable Provisions Shall Be Made In The Panel For Proper Heat Dissipation, Air Aspiration Louvers For Proper Air Circulation Shall Be Provided As Necessary. The Panel Shall Be Suitably Sized To Accommodate All The Components, Providing Necessary Air Clearance Between Live And Non-Live Parts, Providing Necessary Working Clearanceincomer Mccb Four Pole 400A, 415V, 50Ka With Thermal Magnetic Protection Having Door Interlocking To Prevent Operation While The Panel Door Is Open - 01 Power Outgong Terminal Shall Be Sitable For Connection To Down Stream Equipment, Svg Panel, Distribution Boards.Bus Bar Shall Be Of Alumintum With 0.8Ab By Sq.Mm Current Density Covered With Pvc Insulated Sleeves And Mounted On Dmc Insulators Digital Multifunction Meter Panel Mounted Suitable For Measure Voltage, Current, Active Power (Kw), Reactive Power Kvar, Apparent Power Kva, Power Factor Pf, Energy Kwh, Frequency Hz With Cts Of Appropriate Class And Accuracy And Of Suitable Rating For 400A Mccboutgoing Mccb Four Pole 400A, 415V, 50Ka With Thermal Magnetic Protection Having Door Interlocking To Prevent Operation While The Panel Door Is Open-01 , Supply Only Pf Correction Panel With Svg 430Kvar. 415V Panel Indoor Floor Mounted, Free Standing With Ip-31 Degree Of Ingress Protection Made Of Crca Sheet Steel - The Enclosure Shall Have Sturdy Support Structure With Angle Supports As Necessary Enclosure Shall Be Finished Willt Powder Coating, After Finishing 10 Tanks Chemical Treatment. Paint Shed Shall Be Ral-7035 Suitable Provisions Shall Be Made In The Panel For Proper Heat Dissipation. Air Aspiration Louvers For Proper Air Circulation Shall Be Provided As Necessary. The Step-Less Pf Correction Panel System Shall Be Without Any Pf Correction Passive Capacitor Banks, But Single Or Multiple Module Combination Of Static Var Generator, Which Measure The Actual Requirement Of Reactive Currents And Produce And Inject The Same Reactive Currents Inductive Or Capacitive As Per The System Needs To Compensate The Reactive Power Demand Individual Phase Wise There Shall Be One Hmi Cum Svg Controller Digital Signal Processor To Sense The Load Current And Orerate The Svg Modules Connected With The Svg Panel Reaction Time Of That Dsp Shall Be 10 Msec, So That Cicle To Cycle Compensation To Be Established The Hmi Display Unit Shall Have 15Channel Oscilloscope To Display Live-Status Of The 3Phase Voltage, Load Current, Grid Current And Svg Currents, Along With All Major Electrical Pq Parameters Svg Modules Should Have Efficiency Of 98 Percentage And Internal Losses 2 Percent Of Its Full Capacity The Svg Modules Shall Have Intereal Fan For Heat Dissipation By Force Air Cooling Method Maximum 50 Nos Modules Can Be Connected In Parallel Per Ct Set. The Svg Modules Should Be Operated Within The Voltage Range 350V To 480V Ambient Temperature Should Be 0-45 Temp C. Noise Level Shall Be 65Db.Full Rating Of Individual Static Var Generator Module Shall Be 125Kvar 480V, 150A, Which Will Output 107 8Kvar At 415V Ac So, Considering The 4Nos Of Modules It Will Output 430Kvar At 415V Using 4 Nos. 125 Var Modules Rated At 480V With Compensation Range 100Kvar To +125 Kvar Step Less Hmi Shall Have Provision Of Cloud Connectivity To Check Live Status Of The System.Complete All As Specified And Directed. , Material And Labour For Pvc Insulated, Lt Unarmoured Sheathed Frlsh Electric Sense Cable With Copper Multistanded Conductor 1100 Volts Grade, Cross-Sectional Area 4 Sqmm, 6 Core - Laid In Trenches By Pipes By Ducts By Wall By Boarings With Necessary Cable Lugs And Glands, Nuts, Bolts And Washers Etc And Testing Complete All As Specified And Directed , Material And Labour For Chemical Earthing Complete With Copper Bonded 250 Micron Electrode 1500Mm Long And 25 Mm Dia - With Terminal Size 40 X 6Mm Burmed In Ground By Digging A Bore Of 50Mm Dia Surround By Soil Friendly Backfill Compound Non Soluble In Water Including Connection With Galvanized Earth Strip 32X6 Making Pcc Pit Of Size 0.3Mx0.3Mx0 3M Inner Size In Mix 1-3-6 Type Ci With Rcc 1-2-4 Type B1 40 Mm Thick Cover Forced With 6Mm Dia Ms Bars 3 Nos Both Ways With Lifting Hook Made Out Of 8 Mm Dia Bar And Testing On Contction To Achieve Value Not More Than 10 Ohm Complete All As Specified And Directed , Materal And Labour For Earthing Complete With Gl Earth Plate 600Mmx600mmx6mm Thick Electrode Buried Directly In Ground Vertically To A Depth Not Less Than 2.25 Meter - Below Normal Ground Level With Top Edge Of Earth Plate Not Less Than 1.5 Meter Below Ground Level Connected To 32X6mm Galvanised Iron Strip As Earthing Lead Main Earthing Lead By Means Of Galvanized Bolts, Nuts And Washers All As Shown In Electrical Plate No 3 With Connected To Earth Test Point And To Main Switch Board With And Including Adequate Quantity Of Charcol Dust And Common Salt Around Earth Plate And G1 Pipe 20Mm Dia Light Grade For Watering Pipe With Funnel & Wire Messn Including Necessary Earthwork And 40 Mrn Dia Medium Grade Gi Pipe For Protection Of Strip And Pcc 1-3-6 Type C-1 For Earth Pit Thick Pre-Cast Rcc Cover In 1- 2-4 Type B1 With 3 Nos 8Mm Dia Tmt Bars Both Ways Complete All As Specified And Directed By Engineer-In-Charge. , Material And Labour For Earth Continuity Conductor Drawn Through Conduit By Pipe Or Fixed To Pole Or Any Other Indicated Situation For Loop Earthing 20X3mm Galvanised Iron Or Steel Wire , Material And Labour For Earth Continuity Conductor Drawn Through Conduit By Pipe Or Fixed To Pole Or Any Other Indicated Situation For Loop Earthing 32X6mm Galvanised Iron Strip , Supply And Fixing 40 Mm Interconnecting Pvc Pipe Sets And Pipe Fittings Along With Suitable Accessories Complete All As Specified And Directed , Material And Labour For Rcc 1-2-4 Type B-1, Using 20 Mm Graded Stone Aggregate As In Foundation, Including Rafts, Footing, Foundation Beams, - Plinth Beams Columns Etc Under Reamed Piles And Mass Concrete , Material And Labour For Steel Reinforcement For Concrete With Ms Tmt Bar 10Mm Dia And Over Cut To Length, Bend To Shape Required Including Cranking, Bending, - Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire Annealed Not Less Than 0.9Mm Dia Or Sequring With Clips Complete All As Specified And Directed , Warranty Service Amc By Cmc Including Breakdown Service For 5 Years To Ensure The Safe, Reliable, And Efficient Operation Of The Electrical Panel - Its Associated Systems Through Periodic Inspection, Testing, Servicing, And Emergency Support Over A Period Of One Year After One Year Dlp Duration One 1 Years From The Date Of Completion Of Dlp.Services Includedscheduled Quarterly Site Visits, Visual Inspection For Overheating, Corrosion, Physical Damage, Cleaning Ofpreventive Maintenancepanels Dust, Debris, Moisture Control, Tightening Of Connections And Torque Testing Of Terminals, Meggertesting Of Insulation Resistance, Functional Test Of Breakers And Rcds Corrective Maintenancefault Finding And Diagnosis For Reported Issues, Replacement Of Defective Components, Repair Of Wiring Or Damaged Insulation, Troubleshooting Tripping Or Overloads Emergency Supporton-Site Visit Within 48 Hours Of Call Define Sla Clearlydocumentation And Reportingmaintenance Logs And Service Reports After Each Visit Annual Performance Summary Report Total Quantity : 312
|