|
The Subject Of The Order Is The Expansion And Reconstruction Of The Existing Cattery Building. The Expansion Complements The Existing Function And Is Intended To Ensure Proper Care And Shelter For Cats In Accordance With Applicable Regulations. The Existing Building Is Made Of Brick Using Traditional Technology, While The Planned Expansion Involves The Foundation And Adaptation Of Modules Made Of Ready-Made Steel Containers Using Lightweight Technology. The Containers Are To Be Placed On Foundation Footings - A Single-Story Extension Without A Basement, With A Flat Roof With Slopes Enabling Water Drainage. Important Information: In Order To Ensure The Safety Of Animals, The Contractor Will Be Obliged To Implement The Subject Of The Contract In The Following Order: 1) Preparatory Works, Earthworks And Pouring Foundations For The Containers. 2) Foundation And Assembly Of The Containers In Accordance With The Design Documentation. 3) Installation And Installation Works Finishing Of The Newly Constructed Part Of The Cat House (Container Development).4) Commencement Of Works Related To The Reconstruction Of The Existing Building After The Completion Of Stages 1-3 - Possible After Moving All The Animals To The Prepared Container Part.5) Technical Specification Of The Containers: A) Pvc Window Joinery: - Triple-Glazed Unit, - Heat Transfer Coefficient: Uw ≤ 0.90 W/M²k, - Fittings Tilt-And-Turn, Air Vents, Epdm Gaskets. B) External Steel Doors (Warm): - Steel, Insulated (Pu Or Wool), - Heat Transfer Coefficient: Ud ≤ 1.3 W/M²k, - Steel Door Frame, Thermal Insulation Threshold, Peripheral Seals. C) Steel Interior Doors (Cold): - Powder-Coated Steel Door, - Steel Door Frame, - No Thermal Insulation Requirements, - Resistance To Mechanical Damage. D) Floors - Pvc Floor Covering: - Homogeneous Or Heterogeneous Pvc Floor Covering, Commercial, - Use Class: Min. 34/43, - Abrasion Resistance, - Anti-Slip: Min. R10, - Water Absorption: Very Low, - Resistance To Chemicals And Disinfectants, - Welded Grouting (Tightness), - Wall Mounting (Hygienic Plinth). E) Ceilings: Suspended System. F) Container Equipment: - Each Container Should Be Equipped With An Electric Convection Heater N4820 Or Equivalent, - Heating Power: 2000 W, - Power Supply: 230 V / 50 Hz, - Wall Mounting, - Built-In Electronic Thermostat With Temperature Regulation, - Weekly Programmer / Automatic And Manual Mode, - Overheating Protection, - Powder-Coated Steel Casing, - Color White G) External Walls - Containers: - Color Anthracite Ral 7016. The Detailed Scope Of Works Includes: 1) Execution Of Works - Disassembly And Demolition; - Earthworks; - General Construction; - Related To Water, Sewage And Sanitary Installations; - Related To Electrical Installation; 2) Renovation Works; 3) Waste Collection And Disposal. Scope And Description Of The Subject Of The Order Is Determined By: 1) Bill Of Quantities Of Works; 2) Stwiorb; 3) Design Documentation - Published On The Website Of The Ongoing Procedure.
|