Shoring With Spikes D = 15 Cm - Used 5 Times - Manufacturing, Installation And Removal, Manual Scarification, Cutting Concrete Up To 3.0 Cm In Depth, Cleaning Concrete Surfaces With A Steel Brush, Cleaning Concrete Surfaces With Abrasive Blasting Using Steel Shots, Cleaning Reinforcements With A Steel Brush Steel, 07/05/2026 - 09:43:58, Steel Reinforcement For Structures In General, Ca-50, Diameter Of 16.0 Mm, Cutting And Bending On Site, Structural Reinforcement By Butt Welding, For Reconstitution Of The Reinforcement Section, Point, Painting Of Steel Bars With Corrosion Inhibitor With Good Quality Anticorrosive Action, Based Product Polymeric In 2 Coats, Localized Repair With Structural Repair Mortar, Manufacture Of Pre-Molded Concrete Beam, Fck 25 Mpa, Steel 12.5 Mm, 5 Mm Stirrup. Including Reinforcement, Forms, Concreting, Lifting And Locking, Steel Ca-50, 10, 0 Mm, Or 12, 5 Mm, Or 16, Or 20, Bent And Cut, Bracing Structure Replacement Service, Removal Of Steel/Aluminum Tiles For Roofs Of Up To 2 Pitches For Metal Tiles, Including Vertical Transportation, With Reuse, Removal Of Steel Purlins For Roofs Of Up To 2 Pits, Including Vertical Transport, Installation Of Metal Roof Structure Composed Of Steel Purlins Udc Profile 75X40x15 Mm, Including Material And Vertical Transport, Roofing With Steel/Aluminum Tp Tp40 E=0.50Mm, With Up To 2 Pits, Including Lifting, Manual Sanding On Metallic Surfaces On Site. Af_01/2020, Painting With Base Alkyd Paint (Zarcão Type) Applied By Roller Or Brush On Metallic Surfaces (Except Profile) Executed On Site (By Coat). Af_01/2020, Assembly And Disassembly Of Facade Modular Scaffolding, With Metallic Flooring, For Buildings With Multiple Floors (Excluding Scaffolding And Cleaning). Af_03/2024, Installation Metallic Structure Side Closure Composed Of Steel Purlins Udc Profile 150X60x20 Mm, E=3 Mm, Side Closure With Tp40 Steel/Aluminum Tile E=0, Considering Reuse Tile, Including Cutting, Finishing And Hoisting, Masonry Sealing Ceramic Blocks Drilled Horizontally Of 14X19x29 Cm (Thickness 14 Cm) And Laying Mortar Prepared In A Concrete Mixer. Af_12/2021, Chapisco Applied To Masonry (Without The Presence Of Gaps) And Concrete Facade Structures, Using A Trowel. Mortar Mix 1:3 Prepared In A 400L Concrete Mixer. Af_10/2022, Plaster Or Single Putty In 1:2:8 Mortar, Mechanical Preparation With 400 L Concrete Mixer, Manually Applied To Facade Panels Without The Presence Of Gaps, 25 Mm Thickness, Access By Scaffolding. Af_08/2022, Single Putty, In Mortar Trace 1:2:8 Mechanical Preparation, Manually Applied On Internal Walls Of Rooms With An Area Larger Than 10M², E = 10Mm, With Taliscas. Af_03/2024, Galvanized/Zinc Plated Welded Steel Mesh For Masonry, Wire D = *1.20 To 1.70* Mm, Mesh 15 X 15 Mm, (L Mm - Assembly. Af_06/2022, Pillar Or Beam Frame Of Conventional Reinforced Concrete Structure Using 5 Ca-60 Steel, Assembly And Disassembly Of Beam Formwork, Shoring With Wooden Fork, Simple Right Foot, In Plasticized Wood Sheet, 10 Uses. Af_09/2020, Concreting Beams And Slabs, Fck=25 Mpa, For Any Type Of Slab With Buckets In A Ground Floor Building - Laying, Thickening And Finishing. Af_02/2022
|