Construction Work – Anne Frank Ges, Low Voltage System. Tga Elt Heavy Current 1) Heavy Current System According To Din 18382 - Central Safety Lighting - 300 Safety Lights And Escape Route Pictograms - 3600 M Cable Network In Routes - 2300 M Cable Network In Functional Integrity - 1 X Nshv With 7 Nh Outlets With 5 Bus Transformer Meters - 1 X Nshv With 7 Nh Outlets - 8 X Floor Sub-Distribution Boards - 1 X Sub-Distribution For Lighting Control - Line And Cable Network (Mixed Cross-Section And Type) - Cable Routing Systems - 60 M Parapet Duct - 75M Underfloor Systems - 1750M Cable Platforms And Risers - 2200M Collector Holder - 1000M Collector Holder Functional Maintenance - 2000 Pieces Sockets - 100 Pieces Knx Participants - 450 Pieces Connecting On-Site Devices - Lighting 800 X Individual Lights In Different Versions - 2 - S:\G N\04 - In\40I00633 Anne-Frank-Ges, Burgholzstr120\40I006331 Sk Burgholzstr120\6520003151_Extension\07 Project Process\Lph6-7- 8\053 Elt\Ve400_053_Elt_Vordruck-Oeff-Ausschr-Europa_Zi.Docx 03/24/2026 6 X Busbars 450 X Led Surface-Mounted Lights Tga Elt Low Current 2) Telecommunications And Information Technology According To Din 18382 - Surge Protection For All Low-Voltage Centers - Voice Alarm - 1 X Saa With Connection To The Bma - 260 X Loudspeakers - 18 X Loudspeaker Circuits - 3200M Cable In E90 - 2700M Cable On Route - Connecting Cable Between The Existing Buildings Approx. 450 M - 1 Saa Sub-Centre For Connecting The Ela Of The Existing Buildings - Burglar Alarm System - 1 Networked Burglar Alarm Centers With Approx. 16 Alarm Groups - Connection To The Bms - 500M Cables - 450M Connecting Cable Between The Existing Buildings - Call System - 6 Call Sets With Connection - Intercom System - 3 X Video Intercom System With Monitor-Based Intercom System - Public Address System In Cafeteria - Wall Loudspeakers - Induction Loop System With Approx. 600M Of Copper Foil Adhesive Tape - Fire Alarm System - 1 New Control Center Network - Networking With An Existing Control Center - 300 X Automatic Detectors - 3 Smoke Suction Systems With Approx. 250M Of Pipe System - 50 Pieces Of Optical Signaling Devices - 8000M Fire Alarm Line - 400M Fire Alarm Line In Functional Condition
Contact Information
Address
Viktoriastraße 15
Contact No.
023150
Email
ycirak@stadtdo.de
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 112776239
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.