|
Supply, Installation And Maintenance Of Intelligent Transportation Management And Enforcement System Itmes For Muddebihal Town - Comprehensive Maintenance Of All Installed Items As Per The Boq, An Amount Equivalent To 5% Of The Total Capital Cost Of The Project Value Shall Be Released Annually Over 4 Years Towards The Comprehensive Amc.,Supply And Installation Of Led Curb Stones Inserts With Inbuilt High-Intensity Leds For Enhanced Night-Time Visibility, Aesthetic Illumination, And Improved Road Safety And Lane Demarcation.As Per The Directions Of The Engineer In-Charge And As Per Rfp Document,Spring Post 450 Mm (Flexible Bollards)Providing Tubular Marker Made Up Of Polyurethane Used To Divide Opposing Lanes Of Road Users Shall Be Fixible In Nature. Tubular Marker Having Height Upto 450 Mm Shall Be Having 75 Mm Reboundable Work Zone Retroreflective Sheeting As Per Astm 4956 S2 (Application Of Tubular Marker Shall Be Done As Per Irc Sp 55 2014) As Per The Directions Of The Engineer In-Charge And As Per Rfp Document,Providing And Laying Of Hot Applied Thermoplastic Compound 2.5 Mm Thick Including Reflectorising Glass Beads At 250 G/M2 Area, Thickness Of 2.5 Mm Is Exclusive Of Surface Applied Glass Beads As Per Irc 35 2015.The Finished Surface To Be Level, Uniform And Free From Streaks And Holes As Per The Directions Of The Engineer In-Charge And As Per Rfp Document,Supply And Installation Of Convex Mirrors With High-Reflective Visibility For Blind Spot Coverage And Enhanced Road Safety At Intersections And Turning Points. As Per The Directions Of The Engineer In-Charge And As Per Rfp Document,Providing And Fixing Of Median Marker That Are Made Of Tough, High Impact Resistant, Injection-Molded, Thermoplastic Body With An Isosceles Trapezoidal Structure Of Length, Width And Height Not Less Than 15Cm, 10Cm And 10Cm Respectively And Thickness Not Less Than 1.8Mm, The Body Structure Shall Be Rounded At Its Acute Angle, All The Corners And Edges.As Per The Directions Of The Engineer In-Charge And As Per Rfp Document,Providing And Fixing Of Retro- Reflectorised Cautionary, Mandatory And Informatory Sign As Per Irc 67 2022 Made Of Class B Type Iv Retro Reflective Sheeting Fixed Over 2 Mm Thick Aluminium Sheeting Vide Clause 803.1, 3Mm/4Mm Thick Aluminium Composite Material Sheet Depending On The Size Of The Sign Fixed Over The Back Support Frame Of Min 25 X 25 X 3Mm Angle Mounted On A Mild Steel Circular Pipe 65 Nb, 3.2 Mm Thickness.As Per The Directions Of The Engineer In-Charge And As Per Rfp,Providing And Fixing Of Retro- Reflectorised Cautionary, Mandatory And Informatory Sign As Per Irc 67 2022 Made Of Class B Type Iv Retro Reflective Sheeting Fixed Over 2 Mm Thick Aluminium Sheeting Vide Clause 803.1, 3Mm/4Mm Thick Aluminium Composite Material Sheet Depending On The Size Of The Sign Fixed Over The Back Support Frame Of Min 25 X 25 X 3Mm Angle Mounted On A Mild Steel Circular Pipe 65 Nb, 3.2 Mm Thickness.As Per The Directions Of The Engineer In Charge And As Per Rfp,Providing And Fixing Of Retro Reflectorised Cautionary, Mandatory And Informatory Sign As Per Irc 67 2022 Made Of Class B Type Iv Retro Reflective Sheeting Fixed Over 2 Mm Thick Aluminium Sheeting Vide Clause 803.1, 3Mm/4Mm Thick Aluminium Composite Material Sheet Depending On The Size Of The Sign Fixed Over The Back Support Frame Of Min 25 X 25 X 3Mm Angle Mounted On A Mild Steel Circular Pipe 65 Nb, 3.2 Mm Thickness.As Per The Directions Of The Engineer In Charge. As Per Rfp,Installation Of Road Studs Regular Including Surface Cleaning, Fixing With High Strength Epoxy Adhesive Ormechanical Anchor Bolts, Maintaining Straight Alignment As Per Design Layout, Allowing Adequate Curing Time Before Opening To Traffic, And Executing Work During Off Peak Hours With Proper Safety Cones And Barricades, As Per Irc 67-2012 Standards And Manufacturers Recommendation And Direction Of The Engineer-In-Charge. As Per Rfp,Supply Of Road Studs Regular Made Of High Impact Resistant Aluminium Alloy Body With Microprismatic Type Xi Hip Retro Reflective Lenses,Size Approximately 100 Mm 100 Mm 20 Mm, In Amber Or White Color As Per Road Marking Design, Installed Using Epoxy Adhesive Or Anchor Studs On The Pavement Surface For Lane Marking, Junction Delineation, And Pedestrian Safety Guidance, As Per Irc 67 2012 Standards And Manufacturers Recommendation And Direction Of The Engineer In Charge. As Per Rfp,Supply, Installation, Testing And Commissioning Of A Complete Traffic Signal System Comprising Primary, Secondary And Cantilever Poles With Red/Amber/Green And Pedestrian Signals, Timer Display, Traffic Controller With Enclosure, Ups And Battery Backup, Keb Meter Connection With All Required Electrical Accessories, Underground Cabling And Hdpe Ducting, Signal And Power Cables, Earthing, Outdoor Cat6 Communication Cabling.As Per The Directions Of The Engineer In-Charge. - As Per Rfp.,Supply, Installation, And Commissioning Of Facial Recognition Software License With Advanced Face Detection, Matching, And Database Management Features, Valid For A Period Of 5 Years.As Per The Directions Of The Engineer In-Charge. - As Per Rfp.,Supply, Installation, And Commissioning Of High-Performance Gpu / Itms Server With Complete Setup And Configuration For Intelligent Traffic Management System Applications.As Per The Directions Of The Engineer In-Charge. - As Per Rfp.,Supply, Installation, And Commissioning Of Bandwidth Connection With A 5-Year Service Period, Including All Necessary Setup, Configuration, And Activation Charges.As Per The Directions Of The Engineer In-Charge. - As Per Rfp.,Supply, Installation, And Commissioning Of A Poe Network Switch With A Minimum Of 8 + 2 Ports (10/100/1000 Mbps), Switching Capacity Of At Least 13 Gbps, Packet Forwarding Rate Of Minimum 4 Mbps, And Compliance With Ieee 802.3.As Per The Directions Of The Engineer In-Charge. - As Per Rfp.,Supply And Installation Of 1.5 Sq. Mm, 2-Core Power Cable, Suitable For Reliable Outdoor Electrical Connections, With Durable Insulation For Long Term Performance. (In Meter).As Per The Directions Of The Engineer In-Charge. - As Per Rfp.,Supply, Installation, And Commissioning Of Cat6 Utp Outdoor Cable With Solid Bare Electrolyte-Grade Copper Conductor, Polyethylene Insulation (Insulation Diameter 1.04 + Or - 0.05 Mm), Sheath Thickness 0.5 + Or - 0.15 Mm, Pvc Inner Jacket, Pe Outer Jacket, Approximate Overall Diameter 7.1 Mm, Compliant With Iso/Iec 11801 And Operating At A Bandwidth Of 250 Mhz.As Per The Directions Of The Engineer In-Charge. - As Per Rfp.,Supply, Installation, And Commissioning Of A 1 Kva (1000 Va) Pure Sinewave Ups System With An Input Voltage Range Of 180-260 V Ac (+ Or -10%), Output Voltage Of 230 V Ac (+ Or -5%), And 50 Hz (+ Or -1 Hz) Frequency, Providing Greater Than85% Efficiency At Full Load. The System Includes A Sealed Maintenance Free (Smf) 12V, 65Ah Battery (1 No.)As Per The Directions Of The Engineer In-Charge. - As Per Rfp.,Design, Supply, Installation, And Commissioning Of Cables With All Necessary Electrical And Network Accessories, Including Pipes, Connectors, Enclosure Box With Key Set (3 Ft Height, 2.5 Ft Width, 1.3 Ft Depth, 1 Mm Thickness), Hardware Such As Fasteners, Nuts, Bolts, Clamps, And Screws, Power Board, And Network Components Including Rj45 Connectors, Cable Tags, And Messenger Wire For Complete And Secure Installation.As Per The Directions Of The Engineer In-Charge. - As Per Rfp.,Design, Supply, Installation, And Commissioning Of A 1 Kv (1000 W) Keb Meter With Complete Connection And Earthing, Including All Required Documentation And Associated Electrical Components Such As Service Cable, 16A 2-Pole Mcb (Miniature Circuit Breaker), Voltage Protector (Under-Voltage/Over-Voltage Relay), One-Way Gang Box Socket, Bobbins, Fuse, Keb Meter Box, And One Set Of Keys.As Per The Directions Of The Engineer In-Charge. - As Per Rfp.,Design, Supply, Installation, And Commissioning Of A Double-Arm Ms Pole With 2.7 Mm Thickness, 3.5-Meter Arm Length On Each Side, And 7-Meter Overall Height, Powder-Coated For Corrosion Resistance, Complete With Earthing And Inclusive Of All Installation Charges, Ensuring Durable, Safe, And Long-Lasting Deployment.As Per The Directions Of The Engineer In-Charge. - As Per Rfp.,Design, Supply, Installation, And Commissioning Of A Single-Arm Ms Pole With 2.7 Mm Thickness, 5-Meter Arm Length, And 7-Meter Height, Powder Coated For Corrosion Resistance, Complete With Earthing And Inclusive Of All Installation Charges, Ensuring Durable, Safe, And Long-Lasting Deployment.As Per The Directions Of The Engineer In-Charge. - As Per Rfp.,Design, Supply, Installation, And Commissioning Of Ms Pole, Powder-Coated For Corrosion Resistance, Complete With Earthing And All Necessary Installation Accessories And Charges, Ensuring Durable And Secure Mounting For Ptz And Bullet Cameras.As Per The Directions Of The Engineer In-Charge. - As Per Rfp.,Supply And Installation Of 256Gb Sd Card With High-Speed Data Transfer Rate, Suitable For Continuous Video Recording And Secure Data Storage In Surveillance Equipment.As Per The Directions Of The Engineer In-Charge. - As Per Rfp.,Design, Supply, Installation, Configuration, Testing, And Commissioning Of A 4Mp Dual-Light Bullet Camera.As Per The Directions Of The Engineer In-Charge. - As Per Rfp.,Lpu With Edge Analytics Using Jetson Orin/Rockchip/Blaze/Axelera, 1Tb Amron Ssd,Intel/Arm/Risc Cpu 8-32 Cores,Supporting Tensorflow/Pytorch/Paddle Frameworks, Capable Of Advanced Analytics Including Number Plate Recognition, Without Helmet Driver And Co Driver License Detection, Triple Riding,Wrong Side Driving, Use Of Mobile While Driving, And Not-Wearing Seat Belt Driver And Not Wearing Seat Belt Co Driver .With Local Storage M.2 Ssd 4Tb.,Wdr 2Mp 32Xir Network Ptz Camera. As Per The Directions Of The Engineer In-Charge. - As Per Rfp.,Design, Supply, Installation, And Commissioning Of 5 Mp Outdoor Bullet Camera . As Per The Directions Of The Engineer In-Charge. - As Per Rfp.
|