Tender for Providing & Fixing Of Ik10 Ip65 Protected 3.5 Mtr. Height Led Bollard Luminarie With Base Plate Made Of Powder Coated Die Cast Alluminium Housing With Uv Stabalized Pc Diffuser. The System Level Luminous Efficacy = 90 Lumen/W. Smd Leds Is To Be Used, System Cri70, Cct: 3000/4000/6500 K. The Integral Electronic Driver Must Be Potted & Has A Unique Bis R Number Must Be Potted & Has A Unique Bis R Number Constant Current And Internal/External Surge Protection Device Of Min. 4Kv(L-N) And Efficiency 85%, Pf0.9, Thd20% And Input Voltage Range Of 90-270V Ac At 50Hz. System Life Of 30000 Burning Hours With 70% Of Initial Lumens Maintained Light Output In Cool White Or Warm White Colour As Per Engineers Choice. Driver Current 1000Ma Shown In Lm79 Report. Fixture Must Be In Compliance With Bis Standards And T.C . Certificate Complete In All Respect.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem. All As Per Pre Approved By Engineer In-Charge. , Providing And Laying Reinforced Cement Concrete Foundation For Octagonal / Conical Street Light Poles, High Mast Poles As Per Drawing Attach At Table P-4 With Following Procedure & All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .A) Excavation Of Pit For Foundation Size Upto Required Depth Fromground Level B) Dressing Of Pit And Dry Stone Pitching 200 Mm Thick Including Supply Of Stones And Preparing Surface Complete.C) Providing And Laying In Position Cement Concrete Of M-10 Grade Of 75 Mm Thickness D) Reinforcement For Reinforced Cement Concrete Work With Tmt Bars Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete. E) Centring And Shuttering Including Strutting , Propping Etc. And Removal Of Form Work For Footing And Pedestal F) Providing & Fixing Of 2 No. Required Size Plb Hdpe Pipe & Foundation Bolt With Template As Per Oem Recommendations.G) Providing And Laying Reinforce Cement Concrete Of M-25 Grade In Footing And Pedestal Including Curing The Foundation For 7 Days. H) Providing And Fixing Nosing Angle 40 Mm X 40 Mm X 6Mm With 2 No. 100 Mm Long, 10 Mm Dia. Lugs On Each Face. , Supply Installation Testing & Commissioning Of High Mast Lighting System (As Per Plg 07 Of Ilp Uk Techinical Report No 7 Of Ile Uk /Is:875 Part-1 - 2015//Bsen10025/And Is:2062 )Consisting Of Totally Hot Dip Galvanised By Piecewise Single Dipped Method High Mast, Lantern Carriage Suitable For Up To 12 Nos Luminaries With Welded Arm (Excluding Luminares), Mast Head Frame Assembly With Full Cover, Including 1 No. Led 15 Watts Aviation Obstruction Lights, Double Drum Type Self Sustaining Winch, Integral Power Tool Accesible From Door With Padlocking Arrangement (Winch Motor With Control Circuit) Hot Dipped Galvanised Heavy Duty Pipe Lightening Finial, Stainless Steel 6 Mm Dia. Wire Ropes (Aisi 316, 7 / 19 Costruction 3 No. Rope For Lantern Carrage & 2 No. Rope For Winch Assembly ) Foundation Bolt, Torque Limiter,Epr Insulated Pcp Sheathed 5 Core X 2.5 Sq.Mm Trailing Cable, Including Outdoor Type Control Panel For Auto On / Off, Reverse / Forward Motor Operation. The Mast Is Constructed From Mild Steel Plates (As Per Is 5986 Gr. 510 ) Cut And Folded To Form A Polygonal Section, Telescopic Jointed And Welding As Per Bs 5135.Etc. As Required On Existing Foundation. ( See Table P - 03 For Specs.) Oem Must Have Type Test Certificate For Wind Tunnel Test . All As Per Pre Approved By Engineer In-Charge. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .16.0 Mtr Hm (In 2 Section) Suitable For 9 No. Luminaries , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P -I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity 99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Reinforced Cement Concrete / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray (With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr.4 Core 10.0 Sq. Mm , Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm (Width), With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth , Providing & Fixing Of Ik08 Ip-66 Protected High Power Led Flood Light System With Single Piece Pressure Diecast Aluminium Housing, Toughened Glass Diffuser With Suitable Lenses On Led To Achieve Various Beam Angles, Of High Power Led Of 3 To 5 Watt Each . Integrated Potted Driver As A Unique Bis R Number Having Efficiency More Than 85 % And In Compliance To Bis Certified And Trade Mark Certificate. The System Level Luminaire Efficacy =125 Lm/ Wt. Led Driver Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @=300 V Ac And Auto Resetting Safety .Power Factor 0.95 , Thd(I) 10% , Driver Current =750Ma. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs. Electrical Connector , Surge Protection Min =4Kv Internal And 10Kv External But Inside Driver Compartment, System Life Of 50000 Burning Hours With 70% Of Initial Lumens Maintained, Cri70 And Cct 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/ Screen Printing On Die Cast Housing To Allow Traceability/Authenticity. Fixture Shall Be Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate/ Report With Liable Warranty Of Product/Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .High Power Led Flood Light Minimum Lumen Output 25000 Lm , Pipe Earthing As Per Is:3043- 1987 With 3.0 Mtr. Long, 40 Mm Dia. B Class G.I. Pipe Is: 1239 (Part-1) 2004, Equivalent To Bs : 1387With Perforated Holes Of 12 Mm Dia ,Including All Accessories Like Nut,Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In-Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr.2 X 2.5 Sq.Mm , Supply & Fixing Of Gi Pipes Confirming To Is : 1239 P - 1 ( 2004 ) With Flanges Duly Screwed & Welded Including Rubber Washer, Nuts & Bolts Of 8Mm Dia Complete In All Respect.All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . B Class 32Mm Dia , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P -I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity 99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Reinforced Cement Concrete / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray (With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr.4 Core 10.0 Sq. Mm , Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Direct In Ground Including Excavation Of Trench Of Size 75 Cm (Depth) X 35 Cm (Width), With Procedure As Per Following Points:- (A) Make A River Sand Bed Of Height 125 Mm Along The Trench, (B) Lay The Cable In The Middle Of The Trench, (C) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, (D) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thickness And 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr.), (E) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, (F)Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth , Providing And Laying Reinforced Cement Concrete Foundation For Octagonal / Conical Street Light Poles, High Mast Poles As Per Drawing Attach At Table P-4 With Following Procedure & All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr .A) Excavation Of Pit For Foundation Size Upto Required Depth From Ground Level B) Dressing Of Pit And Dry Stone Pitching 200 Mm Thick Including Supply Of Stones And Preparing Surface Complete. C) Providing And Laying In Position Cement Concrete Of M-10 Grade Of 75 Mm Thickness D) Reinforcement For Reinforced Cement Concrete Work With Tmt Bars Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete. E) Centring And Shuttering Including Strutting , Propping Etc. And Removal Of Form Work For Footing And Pedestal F) Providing & Fixing Of 2 No. Required Size Plb Hdpe Pipe & Foundation Bolt With Template As Per Oem Recommendations. G) Providing And Laying Reinforce Cement Concrete Of M-25 Grade In Footing And Pedestal Including Curing The Foundation For 7 Days. H) Providing And Fixing Nosing Angle 40 Mm X 40 Mm X 6Mm With 2 No. 100 Mm Long, 10 Mm Dia. Lugs On Each Face.For 3.5 Mtr, Pole , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr.2 X 2.5 Sq.Mm
|