|
Public Lighting Point With 1 Meter Armsupply And Installation Of Public Lighting Point With 1 Meter Arm (Must Meet All Requirements Of Energisa Unified Technical Specifications), 80W Led Luminaire, 220Vac/60Hz, Cool White Color Temperature (Above 5000K), Minimum Power Factor Of 0.92, Point Public Lighting Point 3 Meter Arm, Petal Public Lighting Point For 3 Luminsupply And Installation Of Public Lighting Point With Petal For Three Luminaires Installed On Top Of The Circular Pole (Must Meet All Requirements Of Energisa Unified Technical Specifications), Three 200W Led Luminaires, Public Lighting Point With Petal For 4 Lumin Supply And Installation Of Public Lighting Point With Petal For Four Luminaires Installed On Top Of Circular Pole (Must Meet All Requirements Of Energisa Unified Technical Specifications), Four 200W Led Luminaires, Double Concrete Pole T 10/300, 05/06/2026 - 15:58:32, 05/06/2026 - 15:58:43, 05/06/2026 - 15:58:44, Double Concrete Post T 11/300, Double Concrete Post T 11/600, Double Concrete Post T 12/600, Double Concrete Post T 12/1000, Circular Concrete Post 12/300, Circular Concrete Post 12/1000, Metal Spacer Secondary Frame 500Mm, Low Voltage Network Structure Multiplexed Cable, Medium Voltage Single-Phase Network Structure, Structure For Medium Voltage Three-Phase Network, Complete Grounding Double T/Circular Post, Transf. Single-Phase Distribution 10Kva Dt/Circ, Transf. Single-Phase Distribution 25Kva Dt/Circ, Transf. Three-Phase Distribution 30Kva Dt/Circ, Transf. Three-Phase Distribution 75Kva Dt/Circ, Transf. Three-Phase Distribution 150Kva Dt/Circ, Fuse Switch On Dt/Circ Pole With Structure, Lightning Arrester On Double T Or Circular Polesupply And Installation Of Lightning Arrester On Double T Or Circular Pole (With Or Without Transformer), With Supports, Structures, And Other Necessary Materials, Removal Of Fuse Key From Dt/Circ Pole, Removal Of Lightning Arrester On Dt/Circular Pole, Multiplexed Aluminum Cables 2X1x35+35Mm², Multiplexed Aluminum Cables 3X1x7070mm² Trif, Multiplexed Aluminum Cables 3X1x120+70Mm²supply And Installation Of Multiplexed Aluminum Cables 3X1x120+70Mm² - Network Three-Phase, Aluminum Cables #50Mm² + 9.53Mm Single-Phase Network, Aluminum Cables 3#50Mm² + 9.53Mm Three-Phase Network, Removal Of Bare Aluminum Cbs From Single-Phase Network, Removal Of Bare Aluminum Cables Three-Phase Network Removal Of Bare Aluminum Cables From Three-Phase Medium Voltage Network And Return To Energisa, Withdrawal Cbs Aluminum Nus Network Low Trifa, Withdrawal Cbs Aluminum Multiplex. 3#35(35)Mm², Removal/Reinstallation Of Concrete Post Dtremoval And Reinstallation Of Concrete Post Dt (Double T) - Relocation Of Post, Removal/Reinstallation Of Circ Concrete Post, Removal/Reinstallation. Structure. For Low Voltage Network, Structural Removal. Single-Phase Medium Voltage Network, Removal/Reinstallation. Three-Phase Medium Voltage Network, Removal Of Concrete Pole Dtremoval Of Concrete Pole Dt (Double T) - Return To Energisa., Removal Of Circular Concrete Pole, Structural Removal. Low Voltage Network, Removal Of Structure Single-Phase Medium Voltage Networkremoval Of Structure For Single-Phase Medium Voltage Network. Undoing And Removing All Existing Connections And Materials., Structural Removal. Three-Phase Medium Voltage Network, Transf. Single-Phase On Double Pole Distribution Transformer Removal Single-Phase On Double-Post T Or Circu
|