Installation Of Rack, Cable Tray, Enclosure Box, Cable Routing, Labelling & Connectivity With Various Equipm ... in India
Tender Notice
TenderID
112713731
Tender Brief
Installation Of Rack, Cable Tray, Enclosure Box, Cable Routing, Labelling & Connectivity With Various Equipment And Supply Of Installation Material & Accessories At Project Sites.
Installation Of Rack, Cable Tray, Enclosure Box, Cable Routing, Labelling & Connectivity With Various Equipment And Supply Of Installation Material & Accessories At Project Sites.-Cable Laying Of 3.5 Core, 25/35/50/70 Sqmm Or Any Suitable Cable, Al Cable Through Trench With Proper Conduit For Connection Of Power Cable. Testing To Be Done To Check Connectivity At Both Ends. (Digging Upto 1.5-2 Feet Or As Per Site Requirement For Underground Cable Laying To Be Done By Vendor). Make Entry Hole In Wall To Pass The Cable Wherever Required As Per Site Requirement A) Transformer To Mvp1 B) Mvp1 To Avr C) Avr To Dg Amf D) Amf To Mvp 2 E) Cable From Mvp 2 To Mvp 3 Or Any Panel F) Dg Room (Mvp-2) To Antenna (Hub) Position Supply And Fixing Of Suitable Type Of Al Lug For 25/35/50/70 Sqmm Cables. (Bottle & Ring Types Can Be Used) Cable Routing In Pair (Black+Red) Of 25 Sqmm Or Any Suitable, Single Core, Cu Cable For Connection Between Ups To Battery Bank, End To End Connectivity Checking (Black +Red) Supply And Fixing Of Suitable Type Of Cu Lug For 25 Sqmm Cu Cable (Ring Types Or Suitable Can Be Used) Cable Routing Of 35 Sqmm Or Any Suitable, Cu Cable Single Core For Earthing Connection And Testing To Be Done To Check Connectivity At Both Ends(Make Entry Hole In Wall To Pass The Cable Wherever Required As Per Site Requirement) A) Cable For Extension From Earth Pit To Earth Box Ac & Dc (Copper Plate) In Power Room. B) Earthing Cables For Avr Body To Jointer C) Earthing Cables For Dg Set Body To Jointer D) Earthing Cables For Dual Amf Body To Jointer E) Earthing Cable From Earth Terminal Fcbc To Fcbc Body 3 F) Earthing Cable From Earth Pit To Mdf/Ddf/6U Rack Box G) Earthing Cables For Dg Set Neutral 1 To Earth Pit H) Earthing Cables For Dg Set Neutral 2 To Earth Pit I) Earth Pit To Jointer At Dg Room J) Earthing Cable For Mvp2 To Jointer K) Earthing Cable For Mvp3 To Earth Box 1) Earthing Pit To Outdoor Equipment (Satellite) M) Earth Box To Ac/Dc Racks Supply And Fixing Of Suitable Type Of Lugs For 35 Sqmm Cu Cable (Ring Types Can Be Used) Cable Routing In Pair (Red+Black) Of Single Core, 16 Sqmm Or Any Suitable Cu Cable Connection And Testing To Be Done To Check Connectivity At Both Ends A) Cable From Sec Dcdbs To Dc Racks (Red+ Black) 4 B) Cable From Ups To Battery Bank (Red+ Black) C) Cable From Inv To Battery Bank (Red+ Black) Supply And Fixing Of Suitable Type Of Lug For 16 5Qmm Cu Cable (Ring Types Or Suitable Can Be Used) Cable Routing Of Single Core, 10 Sqmm Or Any Suitable Cu Cable Connection And Testing To Be Done To Check Connectivity At Both Ends - A) Interconnection Of Battery Of Inverter To Inverter B) 5 Distribution Of Power To Equipment Inside The Rack C) Interconnection Of Batteries Of Inverter In Series Supply And Fixing Of Suitable Type Of Lugs For 10 Sqmm Cu Cable (Bottle & Ring Types Can Be Used) Insulated Copper Cable 3 Core, 6 Sqmm Or Any Suitable Routing Through Cable Tray And Testing To Be Done To Check Connectivity At Both Ends Power Cable From Ups To Acdb A) B) Power Cable Inverter To Distribution Panel (Power Room) 6 C) Power From Mvp 3 To Ups Input D) Power From Mvp 3 To Inv Input E) Power Cable From Acdb To Ac Rack Or Odu (Outdoor Unit) Equipments Supply And Fixing Of Suitable Type Of Lug For 6 Sqmm Cu Cable (Bottle & Ring Types Can Be Used) Cable Routing Of 6 Sqmm Or Any Suitable, Cu Cable For Earthing Connection Through Earthing Cu Strip And Testing To Be Done To Check Connectivity At Both Ends Inside The 7 Rack/6U Rack/Equipment/Outdoor Equipment/Enclosure Box Etc. Supply And Fixing Of Suitable Type Of Lug For 6 Sqmm Cable (Ring Types Can Be Used) Cable Routing Of Single Core, 6 Sqmm Or Any Suitable, Cu Cable With A) Battery Interconnecting Cable (Ups)-Black 8 B) Dcdb To Equipment Inside The Rack Supply And Fixing Of Suitable Type Of Lugs For 6 Sqmm Cable (Bottle & Ring Types Can Be Used) Etc
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 112713731
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.