Repairing And Servicing Of Miscellaneous Fire Fighting Equipments Installed At Ito Building Sanjay Place, Agra-Fabrication, Supplying, Installation Testing & Commissioning Of Electrical Control Panel Of Cubical Construction, Floor Mounted Type, Fabricated Out Of 2Mm Thick Crca Sheet, Compartmentalised With Hinged Lockable Doors, Dust And Vermin Proof, Powder Coated Of Approved Shade After 7 Tank Treatment Process, Cable Alley, Inter-Connection With Suitable Size Copper Conductor Cable/Solid Copper Strip, Having Switchgears And Accessories, Mountings And Internal Wiring, Earth Terminals, Numbering Etc. Complete In All Respect, Suitable For Main Fire Pump, Pressurisation Pump & Diesel Pump Set Complete As Per Cpwd Specification With Following In Coming And Outgoings, Suitable For Operation On 415V, 3 Phase, 50Hz Ac Supply With Enclosure Protection Class Ip 42 As Required : (To Be Installed In Basement Pump House) Incomings 400A, 50Ka 4 Pole Mccb, Ics=100% Icu Rating Digital Voltmeter 0-500V With Selector Switch Ammeter (0-400 A) With Selector Swtich & Cts Etc Led Type Ryb Phase Indicating Lamps, On, Off, Trip Indicating Lamps Set Of Copper Bus Bar 500A Outgoings (Note : All Outgoing Feeders For Pumps Should Have Digital Ammeter With Selector Switches, And Led Type On, Off, Trip Indicating Lamps) Main Fire Pump 200 A, 50Ka Tpn Mccb, Ics=100% Icu, With Fully Automatic Star/Delta Starter Suitable For 75 Hp Pump With Overload Protection, Current Sensing Type Single Phase Preventor Complete With All Acceessories And Internal Wiring Required For Automatic Operation, Selector Switch For Local/Remote, Auto/Manual/Off Operation. Jockey Pump 100 A, 50Ka Tpn Mccb, Ics=100% Icu, With Suitable Hp Fully Automatic Star/Delta Starter With Overload Protection, Current Sensing Type Single Phase Preventor Complete With All Acceessories And Internal Wiring Required For Automatic Operation, Selector Switch For Local/Remote, Auto/Manual/Off Operation Diesel Engine Control Control For Diesel Engine Comprising - Automatic/Manual Selctor Switch & 3 Attempt Starting Device, Timers And Relays As Required, Push Buttons, Start/Stop In Manual Mode Indicating Lamp For High/ Low Lub. Oil Pressure, High Water Temp And Engine On Indication Battery Charger Suitbale For 12V/24 V Dc With Boost And Trickle Selector Switch, 0-30 V Dc Volt Meter, And 0-20 A Dc Ammeter All Standard Relays And Accessories For Automatic Operation Of Diesel Engine 2 3 4 System Controller Designing, Supply, Installation, Testing And Commissioning Of System Controller To Control Operation Of Main Electric Fire Pump, Diesel Pump, Pressurization Pump, Terrace Pump In Sequence As Per Specification Consisting Of Relays, Timers. Sensors, Annunciation Window For Fault Indication, Complete As Per Specifications. Pressure Testing Of Fire Fighting System To Indentify Leakage In Wet Risers / Downcomer System Sprinkler System And Ring Main System Laid Under Ground With The Help Of Local Pressurising Machine And Rectification Of Leakage Including Commissioning Of Sprinkler System In Basement After Proper Testing Of Complete System. Servicing Of 75 Hp Split Casing Pumps By Opening Of Pumps And Checking Of Damage In Impeller And Cleaning Of Scaling Deposited In Impeller, Replacing Its Mechanical Seal, Providing New Packing To Prevent Water Leakage From Pump, Greasing Of Bushing/ Bearing, Replacement Of Rusted Nut Bolt Etc I/C Checking Of All Parts Inside Pump For Any Damages & Scraping Of Rust From Pump By Grinder And Applying Red Oxide Primer And Painting In Suitable Shade As Per Fire Norms Etc Complete As Required. Servicing Of 12.5 Hp Split Casing Jockey Pump By Opening Of Pumps And Checking Of Damage In Impeller And Cleaning Of Scaling Deposited In Impeller, Replacing Its Mechanical Seal, Providing New Packing To Prevent Water Leakage From Pump, Greasing Of Bushing/ Bearing, Replacement Of Rusted Nut Bolt Etc I/C Checking Of All Parts Inside Pump For Any Damages & Scraping Of Rust From Pump By Grinder And Applying Red Oxide Primer And Painting In Suitable Shade As Per Fire Norms Etc Complete As Required 5 Major Servicing, Overhauling, Testing And Commissioning Of Diesel Engine Driven Fire Pump Set I/C Replacement Of Lubricating Oil, Oil Filters, Fuel Filters, Air Filters And Coolant, Checking Of Starter And Electrical Connections, Checking And Repairing Of Auto Start Function Etc Complete As Required. Replacement Of Unserviceable And Outlived Battery By Supplying And Installation Of New 12 Volts, 150 Ah, Lead Acid Battery With Minimum 36 Months Warranty For Self Starting Of Diesel Engine Set I/C Connection , Testing And Credit Back For Old Unserviceable Battery Etc Complete As Required. Painting Of All Firefighting Pipes Of Wet Riser System, Sprinkler System In Basement, Ring Main And Pump House Etc. By Scrapping Of Old Paint And Rust & Making Smooth Clean Surface, Painting With 1 Coat Of Red Oxide Primer And Giving Final Touch By 2 Coats Of Enamel Paint Of Suitable Shade As Per Fire Norms Etc Complete As Required. Supplying, Fixing, Testing And Commissioning Of 16 Guage Fire Hose Cabinet (Ss-304) Of Size 900X600X500 For External Hydrant Etc Complete As Required. Providing, Laying, Testing & Commissioning Of C Class Heavy Duty Ms Pipe Conforming To Is 3589/Is 1239 Including Welding, Fittings Like Elbows, Tees, Flanges, Tapers, Nuts Bolts, Gaskets Etc. And Fixing The Pipe On The Wall/Ceiling With Suitable Clamp/Support Frame And Painting With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade Complete As Required :1Job35,853.0035,853.00 2Nos15,687.0031,374.00 1Job30,320.0030,320.00 9Each17,060.001,53,540.00 80 Mm Dia 150 Mm Dia Supplying And Fixing Single Headed External Yard Hydrant Valve With 1 No. 63 Mm Dia Instantaneous Fm Stainless Steel Coupling And Cast Iron Wheel, Isi Marked, Conforming To Is 5290 (Type A) With Blank Stainless Steel Cap And Chain As Required :10 10Mtrs Mtrs2,088.00 3,886.0020,880.00 38,860.00 10.1 Single Headed Stainless Steel 11 Supplying And Fixing 63 Mm Dia, 15 M Long Rrl Hose Pipe With 63 Mm Dia Male And Female Couplings Duly Bound With Gi Wire, Rivets Etc. Conforming To Is 636 (Type-A) As Required :2Set6,632.0013,264.00 11.1 Stainless Steel (Grade 304 12 Supplying And Fixing First-Aid Hose Reel With Ms Construction Spray Painted In Post Office Red, Conforming To Is 884 Complete With The Following As Required. A) 20 Mm Nominal Internal Dia Water Hose Thermoplastic (Textile Reinforced) Type -2 As Per Is: 12585 B) 20 Mm Nominal Internal Dia Gun Metal Globe Valve & Nozzle. C) Drum And Brackets For Fixing The Equipment On Wall. D) Connections From Riser With 25 Mm Dia Stop Gun Metal Valve & M.S. Pipe And Socket. 12.1 30 M 13 Supplying & Fixing 63 Mm Dia Gun Metal Short Branch Pipe With 20 Mm Nominal Internal Diameter Size Nozzle Conforming To Is 903 Suitable For Instantaneous Connection To Interconnect Hose Pipe Coupling As Required: 13.1 Stainless Steel (Grade 304) 14 Supplying And Fixing Air Vessel Made Of 250 Mm Dia, 8 Mm Thick Ms Sheet, 1200 Mm In Height With Air Release Valve On Top And Flanged Connection To Riser, Drain Arrangement With 25 Mm Dia Gun Metal Wheel Valve With Required Accessories, Pressure Gauge And Painting With Synthetic Enamel Paint Of Approved Shade As Required. 15 Providing, Fixing, Testing & Commissioning Of 15Mm Dia Quartzoid Bulb Type Sprinklers Of Rating 68 Degree Centigrade With Required Accessories2Set9,440.0018,880.00 3 1Nos Nos3,402.00 19,402.0010,206.00 19,402.00 15.1 Pendent Sprinkler 16 Providing & Fixing Of Pressure Switch In M.S. Pipe Line Including Connection Etc. As Required.64 3Nos Nos599.00 1,670.0038,336.00 5,010.00 1 12Nos Nos50,805.00 1,491.0050,805.00 17,892.00 17 Providing, Fixing, Testing & Commissioning Of Installation Control Valve Of Cast Iron Body, Brass/Bronze Working Parts Comprising Of Water Motor Alarm, Bronze Seat Clapper, Clapper Arm And Hydraulically Driven Mechanical Gong Bell To Sound Continuous Alarm When The Wet Riser/Sprinkler System Activates, Pressure Gauges, Emergency Releases, Strainer, Pressure Switch, Cock Valve Complete With Drain Valve And Bypass, Test Control Box, Ball Valves, Ms Pipe Of Required Size, Flanges, Orifice Plate, Gasket Etc Of Follwing Sizes As Required: 17.1 150Mm Dia 18 Providing And Fixing In Position Industrial Type Pressure Gauges With Gun Metal / Brass Valves Complete Etc. As Required. 9 Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray (Galvanisation Thickness Not Less Than 50 Microns) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With Two Numbers Gi Suspenders I/C Base Of Suitable Size Gi Angle, Gi Bolts & Nuts, Fastner Etc As Required. 19.1 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 20 Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Required.20 1Mtrs 2 Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. 22 Excavating Trenches By Mechinical / Manual Means Of Required Width For Pipes, Cables, Etc Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, For All Depth, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M All Kinds Of Soil 22.1 Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia 23Credit For Dismantled Material Including Dismantling Charges. 23.1 23.2 23.3 23.4 23.5 23.6 23.7 23.8Diesel Driven Pump Control Panel Main Pump Control Panel Ms Fire Hose Boxes Pressure Switch Sprinklers Hose Reel With Drum Air Vessel Pressure Gauges
|