0005453 - Cardioverter: End-Tidal Co2 With Range Of 0 To 99 Mm Hg And Resolution Of 1 Mmhg (0.1 Kpa), Battery Of At Least 5 Hours Of Continuous 12-Lead Ecg/Spo2 And Co2 Monitoring, Display Of At Least 8.4, Defibrillation With Cycle Time Shock-To-Shock Less Than 20 Seconds; Non-Invasive Blood Pressure With Range Of Systolic Pressure: 40 To 260 Mm Hg And Diastolic: 40 To 200 Mm Hg; Strip Chart Recorder; Data Storage; Ecg And Arrhythmia Monitoring With Input Of Up To 4 Ecg Waves Displayed And Heart Rate Display Via Digital Reading On Display From 15 To 300 Bpm With Accuracy Of ± 10%; Spo2 Pulse Oximetry With Range From 0 To 100% And Resolution Of 0.01%; 12-Lead Ecg; Feedback Cpr Medication Is Non-Invasive Measurement With Rate 30 Ppm To 180 Ppm (10 Ppm Increments); Accuracy ± 1.5% Ppm. Must Have A Minimum Warranty Of 12 Months And Registration With Anvisa., 0007208 - Pressometric And Volumetric Pulmonary Ventilator, Microprocessed Electronic Pulmonary Ventilator For Neonatal, Pediatric And Adult Patients. Have The Following Ventilation Modes Or Compatible Ventilation Modes: Volume-Controlled Ventilation; Pressure Controlled Ventilation; Synchronized Intermittent Mandatory Ventilation; Ventilation With Pressure Support; Ventilation With Continuous Flow, Cycled In Time And With Limited Pressure Or Guaranteed Volume Mode For Neonatal Patients; Two-Level Ventilation, Non-Invasive Ventilation; Continuous Positive Airway Pressure - Cpap; Back Up Ventilation At Minimum In Spontaneous Modes; Control System: Have Control And Adjustment For At Least The Parameters With The Ranges: Controlled Pressure And Support Pressure Of At Least 60Cmh20; Tidal Volume Of At Least Between 10 To 2000Ml; Respiratory Rate Of At Least 100Rpm; Inspiratory Time: At Least 0.3 To 5.0 Seconds; Peep From At Least Up To 40Cmh20; Inspiratory Sensitivity Per Flow Of At Least Between 0.5 To 2.0 Lpm; Wire2 From At Least 21 To 100%. Monitoring System: Color Screen Of At Least 12 Inches Touch-Screen; Volume Monitoring By Proximal Sensor For Neonatal Patients And Distal For Adult Patients, Being Mandatory Autoclavable For Neonatal Patients - Two Flow Sensors Must Be Provided For Each Patient Category; Main Monitored/Calculated Parameters: Exhaled Tidal Volume, Inspired Tidal Volume, Peak Pressure, Plato Pressure, Peep, Mean Airway Pressure, Total And Spontaneous Respiratory Rate, Inspiratory Time, Expiratory Time, Fio2 With Paramagnetic Or Ultrasonic Sensor Monitoring, I:E Ratio, Resistance, Compliance, Occlusion Pressure And Auto Peep. Presentation Of Pressure X Time Curves, Flow X Time, Volume Doppler, Color Doppler Mode, Spectral Doppler Mode And Real-Time 4D Software Possibility. 2D Mode. Composite Beam Technology And Speckle Noise Reduction Technology, Read/Write Zoom Of At Least 8X. Trapezoidal Image - Enables The Field Of View To Be Increased By 20% In Images With A Linear Transducer. Harmonic Image: Function Applicable To All Transducers. Harmonic Image Of Inverted Pulse. M. Mod Mode
Contact Information
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 112689684
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.