Bids Are Invited For Acquisition Of Hospital Equipment (Tomograph And X-Ray), In Accordance With Mapp Agreem ... in Brazil
Tender Notice
TenderID
112667662
Tender Brief
Bids Are Invited For Acquisition Of Hospital Equipment (Tomograph And X-Ray), In Accordance With Mapp Agreement No. 5548, Of Interest To The Health Department Of The City Of Pacatuba/Ce, All In Accordance With The Specifications Contained In The Terms Of Reference Contained In The Annexes To The Notice.
Factory Digital Radiological Set With X-Ray Parameter Commands Integrated Into The Software Factory Digital Radiological Set With X-Ray Parameter Commands Integrated Into The Software, Detector And Equipment With Single Registration At Anvisa. X-Ray Control And Generator; High Frequency – Multipurpose; Minimum Nominal Power: 64 Kw; Microprocessed Control System; Digital Control Panel Integrated Into The Monitor Control Software; Kv Adjustment Range From Minimum 40 To 150 Kv ± 1.0 V; Minimum Ma Scale 50, 100, 200, 400, 500, 630/800 Ma; Automatic Ma Selection; Minimum Exposure Time 0.001 To 5 Seconds (Or Greater); Kv Range From 40 To 150 Kv; Ma Range 50 To 800 Ma; X-Ray Tube, Digital Rotating Anode Of At Least 300 Khu; Three-Phase Electrical Supply 220 V/380 V (V), 60 Hz; Fixed Table With Floating Top; Radiotransparent Table With Minimum Load Capacity Of 200 Kg; Minimum Size Of 90 X 210 Cm; Longitudinal Displacement Of At Least 90 ± 5 Cm And Minimum Transverse Displacement Of 40 Cm; Electromagnetic Brakes For Transverse And Longitudinal Movements; Anti-Diffusion Grid With Centralization Indexes; Removable Anti-Diffusion Grid For Pediatric Patients; Minimum Grid 103 Lines/40 Lpi; Minimum Focal Distance 100 To 150 Cm; Electromagnetic Brakes To Enable Tilt Movements Of The Stand From 103 Cm To 343 Cm; Tube Holder Stand: Floor/Ceiling Or Floor-Floor Type; Minimum Horizontal (Longitudinal) Displacement Of 200 Cm; Tilt; Spine Rotation From –120° To +120°; Pedal Rotation; Tube Holding Arm; Minimum Vertical Displacement Of 130 Cm Between Extreme Points; Rotation Of The Tube Holder Assembly Of Up To 270°; Indication Of Mechanical Locking Activated By A Button On The Arm Next To The Tube; Plumb Type Tube Angulation Indication (± 90° –0.1° +180°); Steel Structure; Electrostatic Painting Finish; Bucky Mural Minimum Vertical Standard Offset Of 150 Cm; Electromagnetic Brake For Vertical Positioning; Anti-Diffusion Grid, Minimum Ratio Of 103 Lines/In., Multislice Helical Computed Tomography High Performance Multislice Helical Computed Tomography With 16 Channels, Equipment For General Purpose, Multislice, With A Minimum Of 16 Slices, Used To Generate Tomography Images Of The Organs Of Adult And Pediatric Patients, With An Automatic Mas Control System For Dose Reduction. Minimum Gantry Opening 65 Cm, Minimum Angulation Range ± 30°, Digital Acquisition System, Total Cut Time (360°) 1 Second Or Less, Capable Of Continuous Helical Acquisition Without Inter Corruption, Minimum 90% Tube Time (360°) Exposure, Continuous Rotation Angle, Active Range Minimum Beam 20 Mm, Machine Equipped With X-Ray Tube With Rotating Anode And Nominal Focus Of 0.6 160 Cm, Multislice 16 Slice Data Acquisition System With Minimum 16 Detector Rows, 1 Mm Or Smaller Slices With Detector Coverage Of At Least 10:1, Minimum Pitch Of 0.6 And Maximum Of 1.8, Minimum Field Of View Of 50 Cm, Real-Time Image Reconstruction With Possibility For Others Dynamic Modes And Dose Optimization, Iterative Reconstruction System, Table With A Minimum Capacity Of 200 Kg And With Horizontal And Vertical Displacement, Intercom System, Laser System For
Contact Information
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 112667662
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.