Bids Are invited for Om Hvac Bsb Janpath Nd Operation Of Microprocessor Based Hvac System - Operation Of Microprocessor Based Hvac System Of Capacity 5 X 100 Tr Chilling Machines With Screw Compressors And Air Cooled Condensers As Detailed In Annexure A And Ductable Tower Type Split Ac And Split Ac As Detailed In Annexure B By Deputing The Following Staff Skilled Semi Skilled Unskilled 6 Am To 2Pm 1 1 22 Pm To 10 Pm 1 1 2General Shift 9 Am To 5 Pm 1 0 0Notes 1 Staff May Be Asked To Work In Any Shift And Any Day Without Any Extra Cost 2 Bill Processed Receipt Proof Online Salary Transfer Account Epf Esi Contr Presently 12 Perct And 3 25 Perct Ofpay Respas Reqt 3 If Esi And Epf Contributions Rescission Work Initiated 4 Staff Deployed Enrolled Attendance System5 The Contractor Ensure Personnel Meet Defined Standards F6 Operation Of The Pumps 7 Operation Of Ahus And Tfa 8 Oper Electrical Panels9 Recording Readings Chillers Ahus Pumps Digital Temperature Meter 10 To Attend The Floor Complaints 11 Weekly Washing Ahus Filters And Ahus Room12 Chemical Cleaning Ahus Cooling Coil13 General Checking Testing And Attending Minor Faults 14 Out Of Skill Manpower One Skill Operator Electrician15 To Carry Out Leak Test Compressors Condenser Coil With Soap Items Are As Per Schedule Of Work Item 1 , All Inclusive Comprehensive Maintenance - All Inclusive Comprehensive Maintenance Of Following Items As Per Inventory At Per Annexure B Given In Relevant Sections Up To The Required Standards Etc As Per Specification The Items Are 1 Ductable Ac Units2 Tower Split Ac Units3 Split Ac Units Items Are As Per Schedule Of Work Item 2 , Replacement Of Damaged And Worn Out Control And Power Wiring - Replacement Of Damaged And Worn Out Control And Power Wiring Of Star Delta Starter Panel For One Motor In Existing Ahus Electrical Panel With New Pvc Insulated Copper Conductor Wires Of Suitable Size Including Providing And Fixing Of Thimbles Ferrules And New Insulated Fiber Sheet For Proper Insulation Removing Of Existing Contactors Cleaning And Re Fixing The Same In Position After Proper Checking And Tightening Of All Connections Complete As Required Items Are As Per Schedule Of Work Item 3 , Dismantling And Replacement Of Existing Faulty 2 Dp Mcb - Dismantling And Replacement Of Existing Faulty 2 Dp Mcbs In Existing Star Delta Starter Panels Of Chilled Water Pumps On Both Primary And Secondary Sides I C Testing Etc Complete As Required Items Are As Per Schedule Of Work Item 4 , Dismantling And Replacement Of Existing Faulty Mpcb Ms 116 - Dismantling And Replacement Of Existing Faulty Mpcb Ms 116 In Existing Star Delta Starter Panels Of Chilled Water Pumps On Both Primary And Secondary Sides I C Testing Etc Complete As Required Items Are As Per Schedule Of Work Item 5 , Replacement Of Burnt Broken And Rusted Terminal Block - Replacement Of Burnt Broken And Rusted Terminal Block 63 Rating Along With 2 Nos Lugs In The Existing Electrical Panel Of Ahu S Chilled Water Pump S Etc Complete As Required Items Are As Per Schedule Of Work Item 6 , Dismantling And Replacement Of Following Sizes Of Existing Worn Out Faulty Pipe 200Mm Dia 32 Mm Thick Insulation - Dismantling And Replacement Of Following Sizes Of Existing Worn Out Faulty Pipe At Different Floors Levels I C Supplying Laying Fixing Testing And Commissioning Of Nominal Sizes Of Chilled Water Piping Inside The Building With Necessary Cl S Vibration Isolators And Fittings But Excluding Valves Strainers Gauges Etc Duly Insulated With Following Closed Cell Elastometric Nitrile Rubber Of Minimum 45 Kg Cu M Density Thermal Conductivity 0 037 W Mk Or Better At 20 Deg Mean Temperature Class O Insulation Applied By Suitable Adhesive Complete Including Repairing Of Damage To Building Etc As Per Specifications And As Required Complete In All Respect Note The Pipes Of Sizes 150Mm And Below Shall Be M S C Class As Per Is 1239 And Pipes Size Above 150Mm Shall Be Welded Black Steel Pipe Heavy Class As Per Is 3589 From Minimum 6 35Mm Thick M S Sheet For Pipes Upto 350 Mm Dia And From Minimum 7Mm Thick Ms Sheet For Pipes Of 400 Mm Dia And Above A 200Mm Dia 32 Mm Thick Insulation Items Are As Per Schedule Of Work Item 7 A , 150Mm Dia 32 Mm Thick Insulation - 150Mm Dia 32 Mm Thick Insulation Items Are As Per Schedule Of Work Item 7 B , 125Mm Dia 32 Mm Thick Insulation - 125Mm Dia 32 Mm Thick Insulation Items Are As Per Schedule Of Work Item 7 C , 100Mm Dia 32 Mm Thick Insulation - 100Mm Dia 32 Mm Thick Insulation Items Are As Per Schedule Of Work Item 7 D , 80Mm Dia 32 Mm Thick Insulation - 80Mm Dia 32 Mm Thick Insulation Items Are As Per Schedule Of Work Item 7 E , 65Mm Dia 32 Mm Thick Insulation - 65Mm Dia 32 Mm Thick Insulation Items Are As Per Schedule Of Work Item 7 F , Dismantling And Replacement Of Following Sizes Of Existing Worn Out Ndustrial Type Pressure Gauges - Dismantling And Replacement Of Following Sizes Of Existing Worn Out Faulty Components At Different Floors Levels I C Supplying Fixing Testing And Commissioning Of Valves Gauges In The Chilled Water Plumbing Duly Insulated To The Same Specifications As The Connected Piping And Adequately Supported As Per Specifications 8 1 Providing And Fixing In Position The Industrial Type Pressure Gauges With Gun Metal Brass Valves Complete As Required Items Are As Per Schedule Of Work Item 8 1 , Providing And Fixing In Position The Mercury In Glass Industrial Type Thermometers - Providing And Fixing In Position The Mercury In Glass Industrial Type Thermometers Items Are As Per Schedule Of Work Item 8 2 , Butterfly Valve Manual With C I Body Ss Disc A 150 Mm Dia - Butterfly Valve Manual With C I Body Ss Disc Nitrile Rubber Seal And O Ring Pn 16 Pressure Rating For Chilled Water Hot Eater Circulation As Specified A 150 Mm Dia Items Are As Per Schedule Of Work Item 8 3 A , 100 Mm Dia , Dismantling And Replacement Of Following Existing Worn Out Faulty Tpmccb 100 A 16 Ka Tpmccb - Dismantling And Replacement Of Following Existing Worn Out Faulty Tpmccb At Different Floors Levels I C Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel Making Connections Ics100 Perc Icu And Operational Voltage 690V Etc As Required 100 A 16 Ka Tpmccb Items Are As Per Schedule Of Work Item 9 A , 200 A 25 Ka Tpmccb , 630 A 50 Ka Tpmccb , 800 A 50 Ka Tpmccb , Making Suitable Modification Replacement Of Overheated Existing Aluminium Bus Bar - Making Suitable Modification Replacement Of Overheated Existing Aluminium Bus Bar Links Suitable To Fit 630 800 Capacity Tp Mccb I C Cutting Bending Pvc Sleeving Testing Commissioning Etc Complete As Per Site Requirement Items Are As Per Schedule Of Work Item 10 , Dismantling And Replacement Of Existing Worn Out Faulty Paddle Type Water Flow - Dismantling And Replacement Of Existing Worn Out Faulty Paddle Type Water Flow Switch At Different Floors Levels I C Installation Testing And Commissioning With Micro Switch Contacts And Retard Mechanism Complete In All Respects As Required Items Are As Per Schedule Of Work Item 11 , Attending Leakage In The Existing Chilled Water Pipeline - Attending Leakage In The Existing Chilled Water Pipeline Of Various Diameters Including Cutting Of Damaged Portion Edge Preparation Welding Testing And Making The Pipeline Operational Including Providing And Fixing Necessary Scaffolding Ladders Safety Arrangements For Working At Heights Ranging From 15 Feet To 100 Feet In Shaft Area Cleaning The Pipe Surface Applying Anti Corrosive Paint On Welded Joints And Restoring The System To Its Original Condition Complete As Required Items Are As Per Schedule Of Work Item 12 , Replacement Of The Following Items Of Existing Electrical Panels Mnx 32 Contactor Make L Andtac Plant Room - Replacement Of The Following Items Of Existing Electrical Panels I C Identifying And Rectifying The Fault Dismantling Of Existing Defective Parts Fixing Connections Testing Etc As Required A Mnx 32 Contactor Make L Andt Ac Plant Room Items Are As Per Schedule Of Work Item 13 A , Mnx 25 Contactor Make L Andt , 2Noplus2 Nc Add On Blockmake L Andt - 2Noplus2 Nc Add On Block Make L Andt Items Are As Per Schedule Of Work Item 13 C , Overload Relay Mn 2 Of Range 9 To 15 S Make L Andt - Overload Relay Mn 2 Of Range 9 To 15 S Make L Andt Items Are As Per Schedule Of Work Item 13 D , Single Phase Preventer , On Off Push Button With Elements - On Off Push Button With Elements Items Are As Per Schedule Of Work Item 13 F , Led Indication L R Y B G , 3 Way Selector Switch , Star Delta Timer , Digital Voltmetermake Select Or Ss - Digital Voltmeter Make Select Or Ss Items Are As Per Schedule Of Work Item 13 J , Digital Ammeter Make Select Or Ss - Digital Ammeter Make Select Or Ss Items Are As Per Schedule Of Work Item 13 K , V Belt , Painting Of Existing Old Electrical Panel - Painting Of Existing Old Electrical Panel Without Dismantling Including Masking Covering Of Indicators Meters Switches Surface Cleaning Rust Removal 1 Coat Red Oxide Primer Plus Synthetic Enamel Spray Paint And Finishing Etc As Required Items Are As Per Schedule Of Work Item 14 Total Quantity : 371
|