|
Bids Are invited for Custom Bid For Services - Renovation Of The Existing Blood Centre, Phase I, - Demolishing R.C.C. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge. , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. , Taking Out Doors, Windows And Clerestory Window Shutters (Steel Or Wood) Including Chowkhats, Architrave, Holdfasts Etc. And Stacking Within 50 Metres Lead Of Area Beyond 3 Sq. Metres ; , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm , Dismantling Aluminium/ Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Meters Lead As Directed By Engineer-In-Charge. , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved. , Half Brick Masonry With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level.Cement Mortar 1:3 (1 Cement : 3 Coarse Sand); , Extra For Providing And Placing In Position 2 Nos. 6Mm Dia. M.S. Bars At Every Third Course Of Half Brick Masonry (With F.P.S. Bricks). , 12 Mm Cement Plaster Of Mix 1:6 (1 Cement : 6 Fine Sand); , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Form Work5.9 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Shelves (Cast In Situ) , Steel Reinforcement5.22 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Providing And Laying Vitrified Tiles In Floor In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement: 4 Coarse Sand) Jointing With Grey Cement Slurry @3.3 Kg/Sqm Including Groutingthe Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only . Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Glazed Vitrified Tiles Matt/Antiskid Finish/Polished Finish Of Size Size Of Tile 600 X 600 Mm / 600 X 1200 Mm , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade. Area Of Slab Upto 0.50 Sqm , Providing Full Edge Moulding To 18 Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge.For Granite Work , Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc (Volatile Organic Compound ) Content.With Water Thinnable Cement Primer On Wall Surface Having Voc Content Less Than 50 Grams/Litre , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc (Volatile Organic Compound ) Content Less Than 50 Grams/ Litre Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour.Two Coats , Providing And Fixing Tiled False Ceiling Of Specified Materials Of Size 595X595 Mm In True Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanized @ 120 Grams/ Sqm, Both Side Inclusive) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick (Minimum) Sheet, Spaced At 1200 Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm Andsecondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick (Minimum) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting/Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X1.6 Mm Fixed To Ceiling With 12.5 Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85 X 30 X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer-In-Charge. Gi Metal Ceiling Lay In Plain Tegular Edge Global White Color Tiles Of Size 595X595 Mm, And 0.5 Mm Thick With 8 Mm Drop; Made Of G I Sheet Having Galvanizing Of 100 Gms/Sqm (Both Sides Inclusive) And Electro Statically Polyester Powder Coated Of Thickness 60 Microns(Minimum), Including Factory Painted After Bending. , Providing And Fixing Factory Made Upvc Glazed/Wire Mesh Windows/Doors Comprising Of Lead Free Upvc Multi-Chambered Frame, Sash And Mullion/Coupler (Where Ever Required) Extruded Profiles Having Minimum Wall Thickness Of 1.70 Mm For Series R1 And R2 Profiles And 2.10 Mm For Series R3 And R4 Profiles Conforming To En: 12608 In Any Shape, Colour And Design Duly Reinforced With Galvanized Mild Steel Section Made Of Required Shape & Size As Per Cpwd Specification, Upvc Extruded Glazing Beads, Interlocks And Inline Sash Adaptor (Where Ever Required) Of Appropriate Dimension, Epdm Gasket, Hardware. Ss 304 Grade Fasteners Of Minimum 8 Mm Dia With Countersunk Head, Comprising Of Matching Polyamide Pa6 Grade Sleeve For Fixing Frame To Finished Wall As Per Is 1367: Part 1 To 14, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame, Sash & Mullion (If Required) Shall Be Mitred Cut And Fusion Welded/Mechanically Jointed Duly Sealed At All Corners, Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Approved Size And Quality, All Complete As Per Approved Drawing Conforming To Cpwd Specification. & Direction Of Engineer-In-Charge. Section Of Steel Reinforcement And Cross Sections Of Upvc Profiles To Be As Per Design Approved By Engineer-In-Charge. , Casement Door Single Panel With Zinc Alloy (Zamak) 3D Hinges, Multi-Point Locking System With Cylinder, Zinc Alloy (Zamak) Powder Coated Handles On Both Sides. Using R3 Series With Frame (55 Mm & Above) X (50 Mm & Above) & Sash (55 Mm & Above) X (85 Mm & Above) (Height Upto 2.5 Metre) , Casement Door Double Panel With French (False) Mullion With Zinc Alloy (Zamak) 3D Hinges, Multi-Point Locking System With Cylinder, Zinc Alloy (Zamak) Powder Coated Handles On Both Sides, Using R3 Series With Frame (55 Mm & Above) X (50 Mm & Above) & Sash (55 Mm & Above) X (85 Mm & Above) & French (False) Mullion (55 Mm & Above) X (60 Mm & Above). (Height Upto 2.5 Metre). , Fixed Window With Mullion/Transom Using R4 Series With Frame (64 Mm & Above) X (50 Mm & Above) & Mullion (64 Mm & Above) X (70 Mm & Above). (Height Upto 2.5 Metre). , Providing And Fixing Glazing In Aluminium/Upvc Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge. With Toughened Glass Panes Of 8 Mm Thickness (Weight Not Less Than 20 Kg/Sqm) , Providing And Fixing Matt Finished Aluminum Exposed Type Hydraulic Door Closer Of Dorma Ts-71 Make With Necessary Accessories And Screws Etc. Complete For Lead Lined Wooden Doors , Providing And Fixing Of Electromagntic Lock With Access Key Control System With Keyfobes / Card / Kepad For Outside As Per The Requirement Of Door And Palm Sensor From Inside As Per The Direction Of Engineer In Charge. ( Make - Glorz/Dorma/Honeywell) , Providing And Fixing Cupboard Shutter With 19Mm Thick One Side Decorative And Other Side Balancing Lamination Factory Pressed Bwp Grade Marine Ply As Per Is 710 Of Approved Brand Including 2Mm Thick Pvc Edge Banding Tape With Hot Glue By Edge Bending Machine Etc. With Auto Closing Spring Loaded Hinges (Hydraulic Type) Etc. Complete As Per Direction Of Engineerin- Charge.(Payment Of Providing And Fixing Auto Closing Hinges Shall Be Paid Separately) , Providing And Fixing 19Mm Thick Both Side Balancing Lamination Factory Pressed Bwp Grade Marine Ply As Per Is 710 Of Approved Brand Boxes,Shelves,Racks,Almirah,Cupboard And Drawer Etc. Including Necessary Nails,Screws Etc. Complete As Per Direction Of Engineer-In-Charge. , Providing And Fixing Stainless Steel Fancy Handle Of Approved Make Fixed With Ss Screws Etc. Complete As Per Direction Of Engineer-In-Charge. 200 Mm , Providing And Fixing Stainless Steel Soft Closing Spring Hinges At 0 Degree Hinges (Hydraulic Type) Of Approved Make/Brand To Cupboard Shutters With Full Threaded Steel Screws Including Making Necessary Recess In Board And Finished Etc. Complete As Per Direction Of Engineer-In-Charge. , Providing And Fixing Stainless Steel Soft Closing Heavy Type Telescopic Drawer Channels Of Approved Make 500 Mm Long With Screws Etc. Complete As Per Directions Of Engineer- In-Charge. , Providing And Fixing Factory Fabricated Plinth Mounted Under Slab Storage Metal Cabinet As Per Specification Detailed Below:General Specifications: Standards Heavy Duty Under Module, Comprising Of One Or More Drawer, Cabinet With Shutter And Adjustable Height Shelf. Cabinet Shutter Will Be In Double Skin Construction And Shall Be Provided With Heavy Duty, Knuckle And Barrel Type Ss Hinges And Positive Catch Arrangement. The Under Module Shall Be Fabricated Out Of Heavy Gauge Special Grade Crc Sheet In Weld Less Construction And Shall Be Finished With Powder Coating For Extra Ordinary Corrosion Resistance. The Thickness Of Powder Coating Should Be Of 60-70 Microns Which Should Pass Through The Test Of Salt Spray For 1000 Hours And Should Have Scratch Hardness Of 3 Kgs.Overall Dimensions: - W – 900 Mm / 1000Mm X Depth – 600/750 Mm X Height – 600/750 Mm -Detailed Specifications And Thickness Of Crc Items In Each Module:- Cabinet End Panels; Min. 1.2 Mm Thick Crc Sheet- Cabinet Rear Panel And Top Panel; Min. 1.2 Mm Thick Crc Sheet- Cabinet Base Skid; 1.2 Mm Thick Crc Sheet- Cabinet Drawers; 1.2 Mm Thick Crc Sheet- Cabinet Shutters & Drawer Front Panels; Double Skin Const, Min 1 Mm Thick Crc Sheet- Cabinet Main Frame Structure And Drawer Slide Rails, 1.6 Mm Thick Crc Sheet , Providing And Fixing Factory Fabricated Wall Mounted Storage Metal Cabinet As Per Specification Detailed Below:General Specifications: The Cabinets Should Be Suitable For Mounting On Wall. The Cabinets Shall Be Fabricated Out Of Crc Sheets. Cabinet Should Be Provided With 1 Adjustable Shelf. Proper Design, Stiffening / Structural Members Should Be Provided For Strength And Rigidity. Front Door Of The Cabinet Shall Be In Twin Door Design Having Glass Panel With Metallic Frame In Crc Construction. Dimension And Constructional Detail Of The Cabinet Is Furnished Below. The Thickness Of Powder Coating Should Be Of 60-70 Microns.General Specifications:Overall Dimensions: - W – 600 Mm X Depth – 350 Mm X Height – 600 Mm No. Of Shelves: - 1 Adjustable Shelf; Forming 2 Compartments.Construction Detail:-- End Panel, Top Panel & Bottom Panel: - 1.2 Mm Thick Crc Sheet.- Rear Panel: - 1.2 Mm Crc Sheets.- Front Door: - 5 Mm Thick Glass With Metallic Frame In Crc- Shelf: - 1.2 Mm Thick Crc Sheet.- Door Supporting Frames: - 1.6 Mm Thick Crc Sheet.- Door Hinges: - Ss Const. Or Nylon Const.- Door Handles: - Ss 304 Const. , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I/C Fixing The Pipe With Cl S At 1.00 M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge.Concealed Work, Including Cutting Chases And Making Good The Wallsetc.15 Mm Nominal Outer Dia Pipes , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, I/C Fixing The Pipe With Cl S At 1.00 M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge.Concealed Work, Including Cutting Chases And Making Good The Wallsetc.40 Mm Nominal Outer Dia Pipes , Providing And Fixing Uplasticised Ss Connection Pipe With Brass Unions : 45 Cm Length 15 Mm Nominal Bore , Providing And Fixing Ss Waste Pipe For Sink Or Wash Basin Including Ss Waste Fittings Complete.Flexible Pipe 32 Mm Dia , Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931. 15Mm Nominal Bore , Providing And Fixing C.P. Brass Extension Nipple (Size 15Mmx50mm)Of Approved Make And Quality As Per Direction Of Engineer-In-Charge , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Providing And Fixing C.P. Brass Long Nose Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 810 Gms.- 15 Mm Nominal Bore , Providing And Fixing Cp Brass 32Mm Size Bottle Trap Of Approved Quality & Make And As Per The Direction Of Engineer-In-Charge. , Providing And Fixing Cp Brass Single Lever Telephonic Wall Mixer Of Quality & Make As Approved By Engineer In Charge. 15 Mm Nominal Dia , Providing And Fixing Wash Basin / Ss Sink With C.I. Brackets, 15 Mm Dia Cp Brass Single Hole Basin Mixer Of Approved Quality And Make, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wallswherever Required:-White Vitreous China Wash Basin Size 550X400 Mm With A 15 Mm Cp Brass Single Hole Basin Mixer , Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand/Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc. Including Making Connection With The Existing P/S Trap, Complete Inall Respect As Per Directions Of Engineer-In-Charge. , Cutting Holes Up To 15X15 Cm In R.C.C. Floors And Roofs For Passing Drain Pipe Etc. And Repairing The Hole After Insertion Of Drain Pipe Etc. With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), Including Finishing Complete So As To Make It Leak Proof. , Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : 20 Mm Nominal Bore , Supplying And Drawing Following Pair 0.5 Mm Dia Frls/Hffr Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying, Drawing, Installation, Testing And Commissioning Of Cat6 Utp Lszh 23Awg Twisted Pair Cable In Existing Conduit/ On Surface, Category 6 Unshielded Twisted Pair, 4 Pair Should Be Complied As Per Ul/Etl Verification Program For Compliance With Ansi/Tia-568.2-D Standard. Outer Diameter Should Be In The Range Of 6.1Mm Nominal With Operating Temperature Range : -5° To +60°C, Bending Radius : < 4 X Cable Diameter At –5°C ± 1°C And Pulling Force : 11.5Kg Etc. Complete As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessedconduit As Required. , Supplying, Installation, Testing And Commissioning Of Cat6a Copper Information Outlet (Io) With Face Plate Of Color As Per Site Requirement, Should Have Etl/Ul Verification Program Certificate For Compliance With Ansi/Tia-568.2-D. All Copper Cable And Components Should Be From Same Oem To Maintain Compatibility And Interoperability Etc. Complete As Required. , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supplying, Installation, Testing And Commissioning Of Rj45 Connector For Cat 6/6A Cables. Rj45 Modular Plug Supports 4 Twisted Pairs, 8 Positions, 8 Connectors. Housing: Pc, Ul94v-2, Transparent Color, Use For 24- 26 Awg Stranded Wires Etc. Complete As Required. , Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 A Modular Socket Outlet And 15/16 A Modular Switch, Connections Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required. , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required , Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing Of Following Ways Surface/ Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs (But Without Mcbs And Incomer ) As Required . (Note : Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required.) , Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) , Led Panel Light 2X2 Ft. (System Lumen Efficacy =120 <135 Lm/Watt),Supplying, Installation, Testing & Commissioning Of Panel Light 2X2 Ft., Of Following Body Material And Construction As Per Is : 10322 With Driver As Per The Requirement With Driver Efficiency >85%, Operating Voltage Ac 140-270 Volt, Frequency 50/60 Hz, Operating Temp Range -5 0C To 40 0C, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,Thd < 10% , P. F.=0.95, Ip20, Cri >80, Ugr (Unified Glare Rating) <19, Flicker Free, (Flicker Should Be Below 5 %), Life Time (Led, Driver & Electrical Circuitry), Of Minimum 50000 Burning Hours With , 70% Of Initial Lumen Maintained Till Life Ends, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin), Sdcm(Standard Deviation Color Matching) <3, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen Printing On Housing. Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy =120 <135 Lm/Watt Output .Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junctiontemperature Shall Not Rise Above 90°C). Powder Coated Die Cast /Extruded Aluminium Body (Thickness > 1.20 Mm) , Led Down Lighter (Cob Type) (System Lumen Efficacy =105 < 120 Lm/Watt ).Supplying, Installation, Testing & Commissioning Of Led Recessed/ Surface Down Lighter (Round/ Square/ Rectangular) Cob Type Of Following Body Material And Construction As Per Is : 10322 With Driver As Per The Requirement With Driver Efficiency >85%, Operating Voltage Ac 140-270 Volt, Frequency 50/60 Hz, Operating Temp Range -5 0C To 40 0C, Internal Surge Protection Of 2.5 Kv Withshort & Open Circuit Protection ,Thd < 10% , P. F.=0.95, Ip20, Cri >80, Ugr (Unified Glare Rating) < 19, Flicker Free (Flicker Should Be Below 5%), Life Time (Led, Driver & Electrical Circuitry), Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends, Cct 3000°K / 4000°K / 5700°K / 6500°K (As Per Ansi Bin), Sdcm (Standard Deviation Color Matching) <3, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Confirming To Relevant Bis Standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing Complete In All Respect I/C External Connections With 1.5 Sq.Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy =105 And <120 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C) Powder Coated Die Cast /Extruded Aluminiumbody Including Trim With Aluminium Reflector , Providing ,Laying ,Testing & Commissioning Of C Class Heavyduty Ms Pipe Confirming To Is 3589/Is 1239 Including Welding ,Fitting Like Elbow Tees Flanges Tapers Not Bolts Gaskets Etc And Fixing The Pipe On The Wall/Ceiling With Suitable Cl /Support Frame And Painting With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade Complete As Required , 25 Mm Dia , 50 Mm Dia , Supplying, Fixing, Testing And Commissioning Of Butterfly Valve Ofpn 1.6 Rating With Bronze/Gunmetal Seat Duly Isi Marked Complete With Nutbolts, Washers, Gaskets Confirming To Is 13095 Of Following Sizes As Required: , 50 Mm Dia , Providing ,Fixing ,Testing & Commissioning Of 15Mm Diaquartzoid Bulb Type Sprinkler Of Rating 68 Degree Centigrade With Required Accessories: , Upright Sprinkler , Supplying, Fixing, Testing And Commissioning Of Multisensory Detector,Optical/Thermal ,Model No Avenar 4000,Fap-425-Ot-R Withthe Integration Of The Existing System/Panel (Make Bosch) With Required Accessories( Verbal Estimate Received From The Existing Vender)
|