|
Tender for Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Stay Wire 7/10 Swg , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , St Pole 13 M- Is 410 Sp- 72 , Stay Set 16X1800 , Acsr Dog Conductor , Acsr Weasel Conductor , A.B.Cab. L.T. (3X95)+ (1X70)+ (1X16)Sq.Mm , A.B.Cab. L.T. (3X120) , 11 Kv H.T.Xlpe Cable 3X185sq.Mm , Lt Abc 3X50+1X35+1X16 Sq.Mm , 33 Kv H.T. Xlpe Cable 3X300 Sq.Mm. , Earth Rod 2540X20 Mm , 11 Kv completion Poly. Disc Insulator 45 Kn , 11 Kv Composite Polymer Pin Insulator , 33 Kv Polymer Disc Insulator (B&S) 70 Kn , 33 Kv Composite Polymer Pin Insulator , 33 Kv Disc Fitting (B&S) Dog/Racoon 70 Kn , Ms Channel 100X50 Mm , 33 Kv Cross-Arm 100X50 Mm V-Type , Disc Fitting 45 Kn (T&C) , Gi Wire 4Mm/ 8 Swg , Gi Wire 5 Mm/6 Swg , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 33 Kv Gi Pin With Nut , M.S. Guarding Angle 1.8Mtr , 33 Kv Xlpe Cable Box 3X300 , G.I. Bracing Angle 65X65x6x2700mm , Droper Channel 100X50mm , Top Channel (125X65x65x6mm) 33 Kv Line , Stay Set Gi 20X1800 Mm , 3-Ph Distribution Box , V Type X Arm Angle , 11 Kv Vcb Outgoing , 11 Kv Cable Box O/D 3X185sq.Mm , M.S. Angle 75X75x6 Mm , M.S. Angle 65X65x6 Mm , Ms Channel 125X65 Mm , 11 Kv Ct/Pt Ctr200/5Amp , 11 Kv Metering Cubical , Erection And Fixing Of The Following Materials As Per Relevant Respo/Departmental Norms And Specifications, Including Proper Installation, Alignment, Tightening, And Commissioning At Site. The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , Stay Wire 7/10 Swg , Stay Set 16X1800 , Stay Set Gi 20X1800 Mm , 11 Kv completion Poly. Disc Insulator 45 Kn , M.S. Angle 65X65x6 Mm , 11 Kv Composite Polymer Pin Insulator , Ms Channel 100X50 Mm , Lt Abc 3X50+1X35+1X16 Sq.Mm , 33 Kv Polymer Disc Insulator (B&S) 70 Kn , 33 Kv Cross-Arm 100X50 Mm V-Type , 33 Kv Disc Fitting (B&S) Dog/Racoon 70 Kn , Disc Fitting 45 Kn (T&C) , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 33 Kv Gi Pin With Nut , M.S. Guarding Angle 1.8Mtr , 33 Kv Composite Polymer Pin Insulator , G.I. Bracing Angle 65X65x6x2700mm , Droper Channel 100X50mm , Top Channel (125X65x65x6mm) 33 Kv Line , Stay Set Gi 20X1800 Mm , 3-Ph Distribution Box , V Type X Arm Angle , 11 Kv Vcb Outgoing , Ms Angle 75X75x6 Mm , Ms Channel 125X65 Mm , 11 Kv Ct/Pt Ctr200/5Amp , 11 Kv Metering Cubical , Erection & Fixing Of Single Pole Structure Of Following Pole Of 11 Kv Line Along With X-Arm And Pin Insulator After Digging Of Suitable Pits Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Stone Pad, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Plain Cement Concrete Pole 8.5 Mtrs , Plain Cement Concrete Pole 11 Mtrs , St Pole 13 Mtrs , Erection Of 11Kv Double-Pole Structure After Digging Of Suitable Pits On Following Pole With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Plain Cement Concrete Pole 8.5 Mtrs , Plain Cement Concrete Pole 11 Mtrs , Erection Of 33Kv Double-Pole Structure After Digging Of Suitable Pits On St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Erection Of 33Kv Tri-Pole Structure After Digging Of Suitable Pits On St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Erection Of 33Kv Four-Pole Structure After Digging Of Suitable Pits On St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Erection & Fixing Of 33Kv St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Grouting Of Following St/Pcc Supports In cement concrete 1:3:6 (Cement, Sand & 40Mm Brick Ballast) Grouting Will Be Done In The Block Of Size (450X450)Mm X1/6Th Of Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge. , Plain Cement Concrete Pole 8.5 , Plain Cement Concrete Pole 11 Mtr. Long , Stp 13 Mtrs Long , Construction Of T/F Plinth Suitable For 160/250/400 Kva T/F (Size 2X2x1.5 Mtr) After Digging Of Earth And Construction With 14 Bag Cement, Fine Sand, Coarse.Sand, Brick Ballast, 1St Class Bricks 6000, Stone Ballast (40Mm), Ms Channel 125X65mm (54 Kg), Ms Twisted Bar 20 Mm (50 Kg) & Ramming The Same, Including Cost Of All Material & Labour, As Per Direction Of Site Incharge. (All Matreial/ Labour/ T&P Use For Construction Of Plinth Will Be Provided By Contractor) , Safe Dismantling, Loading, Transportation, Unloading, Re-Erection, Testing And Commissioning Of 25/63/100/250 Kva Distribution Transformers Of 11/0.4 Kv Rating, Including Complete Shifting From Existing Location To New Site As Per Departmental Instructions; The Scope Of Work Shall Include Disconnection Of Ht/Lt Lines, Removal And Refixing Of All Associated Technical Accessories Such As Go Switch Set, Drop Out Fuses, Lightning Arrestors, Ht/Lt Bushings, Earthing Arrangements, Breather, Conservator Connections, Oil Level Indicators, Silica Gel, Protection Devices And All Allied Fittings; Proper Handling Using Suitable Capacity Crane/Chain Pulley Block, Providing Required T&P, Skilled Labour, Safety Measures To Avoid Any Mechanical/Electrical Damage, Checking Of Transformer Oil Level And Filtration If Required, Tightening Of All Connections, Re-Alignment, Replacement Of Minor Damaged Components, And Ensuring Proper Earthing And Guarding; Including Carriage Of Transformer And Accessories On Suitable Vehicle Over All Types Of Roads, Complete Installation On Plinth/Structure, Connection With Existing Network, Testing Of Ir Value, Ratio Test And Trial Run For Satisfactory Operation, Strictly As Per Relevant Standards And Direction Of Engineer-In-Charge; The Rate Shall Be Inclusive Of All Labour, Tools & Plants, Transportation, Insurance, Loading-Unloading, And Incidental Charges Required To Complete The Work In All Respects. , 25 Kva Transformer On Double Pole , 63 Kva Transformer On Double Pole , 100 Kva Transformer On Double Pole , 250 Kva Transformer On Plinth , Complete Earthing System For 25 Kva, 63 Kva And 100 Kva Distribution Transformers, Comprising Of Supply And Installation Of Suitable Size G.I./Copper Earth Electrodes (Pipe/Rod Type Of Standard Length) Driven Or Installed In Earth Pit Of Required Dimensions, Including Excavation And Backfilling With Layers Of Charcoal/Coke And Common Salt, Watering Arrangement With G.I. Pipe And Funnel With Wire Mesh, And Construction Of Brick Masonry Chamber With Ci/Rcc Cover; Providing And Laying Of G.I. Strip/Wire Of Required Size From Transformer Body, Neutral And Lightning Arrester (If Applicable) To Earth Electrode, Including All Connections With Nuts, Bolts, Washers, Lugs And Proper Clamping, Testing Of Earth Resistance And Ensuring Value Within Permissible Limits As Per Relevant Standards; The Scope Includes All Materials Such As G.I. Pipe/Rod, G.I. Strip/Wire, Charcoal, Salt, Bricks, Cement, Sand, Ci/Rcc Cover, Etc., And All Labour, Excavation, Refilling, Watering, Transportation, Handling, Testing, And All Tools & Plants (T&P) Required For Complete And Satisfactory Installation As Per Respo/Standard Specifications And Direction Of Engineer-In-Charge. , Providing And Installation Of Maintenance-Free Chemical Earthing System For 250 Kva Distribution Transformer, Comprising Of Supply And Erection Of Approved Make Chemical Earth Electrode (Gi/Copper Bonded, Of Standard Length And Diameter) Installed In Drilled/Bored Hole Of Required Depth In All Types Of Soil, Including Backfilling With Highly Conductive Earthing Compound (Bfc/Graphite Based) To Achieve Low And Stable Earth Resistance; Providing Separate And Distinct Earthing For Transformer Body, Neutral And Lightning Arrester (If Applicable) Using Required Number Of Chemical Electrodes Interconnected Where Necessary; Construction Of Earth Pit Chamber With Brick Masonry, Plastering And Heavy Duty Ci/Rcc Cover With Provision For Watering/Inspection; Providing And Laying Of Gi Strip (E.G., 50×6 Mm) Or Suitable Copper Strip From Transformer Body, Neutral Point And La To Respective Earth Electrodes, Including All Connections With Nuts, Bolts, Washers, Lugs, Clamps And Anti-Corrosive Treatment; Testing Of Earth Resistance To Ensure Values Within Permissible Limits As Per Is/Respo Standards And Ensuring Long-Term Stability Without Frequent Maintenance; The Scope Includes Cost Of All Materials Such As Chemical Electrodes, Backfill Compound, Gi/Copper Strips, Bricks, Cement, Sand, Covers, Water, Etc., And All Labour, Drilling, Installation, Refilling, Carriage, Loading/Unloading, Handling, Testing, Commissioning And All Tools & Plants (T&P) Required For Complete And Satisfactory Execution Of Work As Per Standard Specifications And Direction Of Engineer-In-Charge. , Construction Of Safety Fencing (Ms) Size 3X3x2 Mtr. For Dist. Transformer 11/0.4 Kv Sub Station, With Supply Of Material Required For Ms Fencing (50X50x3 Mm) M.S. Wire Mesh Construction Utilizing Vertical Post Duly Grouted/Fitted In Ground/On Floor. Horizontal Angle/T-Iron To Be Fitted On Vertical Posts. Pickets (If Required) Fitted To Rail And Gate To Facilitate Entry And Exit. The Vertical Posts/Horizontal Post Shall Be Made Of M.S. Angle 65X65x6mm. Such Post Shall Be Kept Preferably At Distance Of 800-1000 Mm. And Shall Be Grounded With cement concrete Ratio 1:4:8. The Length Of Vertical Post Shall Be Sufficient To Take Care Of Fencing As Requirement At Site, And As Per Direction Of Site Incharge. (All Matreial/ Labour/ T&P Use For Construction Of Plinth Will Be Provided By Contractor) , Providing, Installing, Testing And Commissioning Of Tailless Unit Suitable For 250 Kva Distribution Transformer, Including Dismantling Of Existing Tail Connections (If Any), Supply And Fixing Of Required Lt/Ht Connectors, Busbar Arrangements, Insulated Sleeves, And Necessary Termination Accessories; Complete Modification Of Transformer Lt Side To Tailless Configuration Ensuring Proper Phase Segregation, Insulation And Mechanical Strength; Including Providing And Fixing Of Suitable Size Aluminium/Copper Lugs, Glands, Ferrules, Heat Shrink Sleeves, Pvc Insulation Tape, Nut-Bolts, Washers And All Jointing Materials As Required; Making Proper Cable Terminations, Dressing And Clamping Of Cables With Gi Clamps; Providing And Ensuring Effective Earthing Of The Tailless Unit With Gi Strip/Wire And Connecting To Existing Earthing System; Including Painting Of Modified Portion With Suitable Anti-Corrosive Paint; Complete Testing For Continuity, Insulation Resistance And Proper Load Transfer; The Work Shall Be Carried Out As Per Relevant Is Standards, Respo/Departmental Specifications And As Directed By Engineer-In-Charge; The Rate Shall Include Cost Of All Materials, Labour, Tools & Plants (T&P), Handling, Loading/Unloading, Transportation, And All Incidental Works Required To Complete The Job In All Respects. , Providing, Laying, Jointing And Commissioning Of 140/200 Mm Dia (Od) Pn-4, Pe-80 Grade Uv Stabilized Hdpe Pipe In 6.0 Mtr Standard Length By Trenchless (Hdd/Drilling) Method For Underground Cable Protection, Including Excavation Of Suitable Size Launching And Receiving Pits, Alignment And Preparation Of Bore Path, Drilling, Reaming And Insertion/Pulling Of Hdpe Pipe, Jointing By Butt Fusion/Electrofusion With All Necessary Fittings Such As Couplers, Bends And End Caps, Ensuring Proper Alignment And Leak-Proof Joints; Including Providing And Laying Of Warning Tape, Route Markers And Identification System; Complete With All Required Tools & Plants (T&P) Such As Hdd Machine, Drilling Machine, Compressor, Generator, Welding Machine, Including All Consumables, Loading/Unloading, Handling And Safe Stacking At Site; Including Dewatering (If Required), Traffic Control, Barricading And Safety Measures; Also Including Restoration Of Road, Footpath, Drain Or Any Other Surface Under Row (Right Of Way) Conditions To Original Condition And Disposal Of Surplus Earth/Muck; Complete In All Respects As Per Relevant Is Standards, Respo/Departmental Norms And Direction Of Engineer-In-Charge, With All Material, Labour, T&P, Transportation And Incidental Charges Included In The Rate. (Rate Will Be Charge As Per Actual Length Of Work) , 200 Mm Dia For 33 Kv Line , 140 Mm Dia For 11 Kv Line , Laying Of Following Cable Undergound Into Hdpe Pipe, Spare Cable Shall Be Left In The Loop Shape At Both Ends As Per Respo/Norms, As Per Direction Of Site Incharge.(Rate Will Be Charge As Per Actual Length Of Work) , 11 Kv H.T.Xlpe Cable 3X185sq.Mm , 33 Kv H.T. Xlpe Cable 3X300 Sq.Mm. , Manually Digging Excavation Of Trench Of Size 0.50 M Width × 1.00 M Depth In All Types Of Soil Including Dressing, Levelling And Disposal Of Surplus Excavated Earth Within Specified Lead As Per Respo/Drawing Norms And Direction Of Engineer-In-Charge; Supplying And Laying Of Brick Masonry (Class Designated) In Cement Mortar For Side Protection, Providing And Filling Of Sand Cushioning At Bottom And Around The Laid Cable, Followed By Laying Of Plain Cement Concrete (Plain Cement Concrete) Of Required Grade For Base And Protective Covering Over Trench; Thereafter, Placing And Proper Alignment Of Xlpe Cable Within The Complete Trench, And Covering The Trench With Brick/Cc Slab Protection Including Backfilling With Excavated Earth In Layers, Watering, Ramming And Proper Compaction Complete In All Respects; The Scope Of Work Includes Cost Of All Labour, Materials (Bricks, Sand, Cement, Aggregates, Water Etc.), Handling, Loading/Unloading, Carriage, And All Tools & Plants (T&P) Required For Excavation, Laying And Finishing Works, With All Safety Precautions, As Per Standard Specifications And Directions Of Site In-Charge. (The Firm Will Be Fully Responsible For This Work And Taking Necessary Permission), As Per Direction Of Site Incharge (Rate Will Be Charge As Per Actual Length Of Work). , Laying And Installation Of 11 Kv Grade, 3 Core × 185 Sq.Mm Xlpe Insulated, Armoured Aluminium Conductor Cable In Underground Trench In Double Circuit Formation, Including Careful Handling, Dressing And Alignment Of Cable Along The Route As Per Respo/Drawing Norms And Direction Of Engineer-In-Charge; Laying Of Cable Over Prepared Sand Bed, Maintaining Proper Spacing Between Circuits, And Ensuring Identification And Phase Marking; Providing Extra Length Of Cable At Both Ends In Loop Formation For Future Jointing/Termination (Spare Cable To Be Left In Loop Shape At Each End) As Specified; Covering Of Cable With Sand Cushioning, Protective Bricks/Tiles/Cc Slabs And Backfilling Of Trench With Excavated Earth In Layers, Watering, Ramming And Proper Compaction Complete In All Respects; Including Supply Of All Consumables Such As Sand, Bricks, Cable Markers, Route Indicators, Etc., And All Labour, Loading/Unloading, Carriage, Handling Charges, Testing Prior To Commissioning, And All Tools & Plants (T&P) Required For Safe And Proper Execution Of Work As Per Standard Specifications And Site Instructions. , Providing & Fixing Of G.I. Pipe 6Dia Class-B Over 11Kv/33 Kv Xlpe Cable Before Mounting The Cable At Double Pole. The Work Includes Fitting Of Clamps, Sealing Of Top And Bottom Of Pipe And One End Of Pipe Is To Be Burried Under Earth About 500Mm Earch Including Mounting And Clamping The Cable On Double Pole Structure And Making Connection With Overhead Line At Both Ends, As Per Direction Of Site Incharge. , Making And Filling Of 11Kv/33Kv Cable Jointing Kit, Indoor/Outdoor Type, After Duly Plumbing And Taping Of Suitable Xlpe Cable, Providing, Fixing And Crimping Of Proper Size Good Quality Lugs, Including Cost Of Lugs And Tape Etc., As Per Respo Norms, And As Per Direction Of Site Incharge. , 11Kv Cable Jointing Kit 3X185 Sq.Mm. , 33Kv Cable Jointing Kit 3X300 Sq.Mm. , Laying , Stringing And Final Sagging Of Acsr Weasel Conductor, As Per Respo/ Drawing Norms And As Per Direction Of Site Incharge. , Laying , Stringing And Final Sagging Of Acsr Dog Conductor, As Per Respo/ Drawing Norms And As Per Direction Of Site Incharge. , Laying And Stringing Of Following Lt Aerial Bunched Cable (Abc) On St/Pcc Poles, Including Proper Hanging, Dressing And Fixing Of Cable With Necessary Clamps, Supports, Nuts & Bolts (To Be Arranged By The Contractor), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Lifting, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Lt Aerial Bunched Cable (Abc) (3×95 + 1×70 + 1×16 Sq.Mm) , Lt Aerial Bunched Cable (Abc) (3×120 + 1×95 + 1×16 Sq.Mm) , Fabrication Of Guarding Angle Other Requisites Material For Guarding By Drawing 02Nos G.I Wire And Making Loop At Suitable Distance As Per Respo Drawing/Norms By Providing Holding Clamps, 02Nos. Eye Bolts Made Of M.S. Round Size 12Mm Dia-100Mm Long & Cross Arm Clamps Made Of M.S. Flat Of Size 50X6mm And Bolts As Per Norms Of Respo Norms, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. As Per Direction Of Site Incharge. (Only Guarding Angle & Gi Wire Will Be Provided By Department). , G.I. Wire 4Mm/ 8 Swg , G.I. Wire 5Mm/ 6 Swg , Grouting & Fixing Of Stay Set (16X1800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Stay Set (16X1800) , Stay Set Gi (20X1800) , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing And Fixing Of Insulation Piercing Connector (Ipc) Complete In All Respects, Including Proper Installation, Tightening And Ensuring Safe And Reliable Connection, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of All Types Of Clamps Including F-Type Clamps, Holding Clamps, Cross-Arm Clamps, Lt Clamps, Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Dead & Clamp , Suspension Clamp , F-Bracket With Clamp , Cross Arm Holding Clamp , Providing And Fixing Of Nut & Bolts As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Lt Fuse Set Complete On 25/63/100 Kva Transformer In All Respects, Including Proper Mounting, Connection, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Eye Hook Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Stone Pad 300X300x75 Of Approved Quality And Specified Size At Pole/Support Locations, Including Excavation Of Suitable Size Pit, Preparation Of Base, Dressing, Leveling, And Proper Placement In Line And Level As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge, Including Refilling, Ramming And Consolidation To Ensure Stability; The Scope Of Work Includes Cost Of All Labour, Loading/Unloading, Carriage, Alignment And All Incidental Works Required For Complete Execution, And All Tools & Plants (T&P), Equipment And Tackles Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Danger Board Of Approved Design, Size And Material With Proper Statutory Warning Sign And Lettering, Complete With Suitable M.S. Clamp, Nuts, Bolts And Washers, To Be Rigidly Mounted On Pole/Structure At Required Height Ensuring Proper Alignment And Visibility, As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Drilling Of Holes, Fitting, Tightening, Handling, Loading/Unloading, Carriage To Site, And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Barbed Wire Of Approved Quality And Specification In Position, Stretched And Secured On Poles/Structures With Suitable Binding Wire, Staples, Clamps Or Other Approved Means, Maintaining Proper Tension, Alignment And Height As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site, Cutting, Jointing, Tightening And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Stay Insulator Of Approved Make, Type And Rating In Stay Set Assembly, Including Proper Placement Between Stay Wire Lengths, Making Necessary Connections, Tightening And Ensuring Correct Alignment And Insulation As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site, Cutting, Jointing And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of I-Bolt Of Approved Size And Quality For Guarding Angle, Complete With Nuts, Bolts, Washers And Necessary Accessories, Including Drilling Of Holes In Angle/Pole As Required, Proper Insertion, Fitting, Tightening And Ensuring Correct Alignment And Rigidity As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Number Plate Of Approved Size, Design And Material With Proper Painting/Printing Of Identification Number And Lettering, To Be Securely Mounted On Pole/Structure At Suitable Height Ensuring Proper Alignment And Visibility, As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Drilling Of Holes, Fixing With Suitable Clamps, Nuts, Bolts Or Binding Wire As Required, Handling, Loading/Unloading, Carriage To Site And All Incidental Works Necessary For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of 11 Kv Draw Out Fuse Set Of Approved Make And Rating, Complete With All Standard Accessories, Mounted On Pole/Structure With Suitable Clamps, Nuts, Bolts And Connectors, Including Proper Alignment, Tightening And Making Necessary Electrical Connections For Safe And Reliable Operation As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site, Erection, Testing And Commissioning And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment, Tackles And Testing Instruments Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of 11 Kv Smc Danger Board Of Approved Design, Size And Material With Proper Statutory Warning Sign And Lettering, Complete With Suitable Clamps, Nuts, Bolts And Washers, To Be Rigidly Mounted On Pole/Structure At Required Height Ensuring Proper Alignment And Visibility As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Drilling Of Holes, Fitting, Tightening, Handling, Loading/Unloading, Carriage To Site And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing Paint And Carrying Out Painting Of Pole With Approved Quality Paint System, Including Thorough Surface Preparation By Cleaning, Scraping, Wire Brushing And Removal Of Rust, Dirt And Loose Materials, Applying Primer Coat Where Required And Finishing With Two Or More Coats Of Approved Paint Of Specified Shade, Including Marking/Numbering If Directed, Complete In All Respects As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage Of Materials To Site And All Incidental Works Necessary For Satisfactory Completion, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Construction Of Meter Room Of Internal Size 8× 8× 10 Height, Including Setting Out, Excavation Of Foundation In All Types Of Soil, Dressing And Disposal Of Surplus Earth Within Specified Lead; Providing And Laying Plain Cement Concrete Of Required Grade For Foundation Base, Followed By Construction Of Brick Masonry In Cement Mortar Of Approved Class For Foundation And Superstructure Walls Of Required Thickness, Including All Leads And Lifts; Providing Reinforced Cement Concrete Lintel And Roof Slab (Solid Slab) Of Required Thickness Using M-20 Grade Concrete With Centering, Shuttering, Vibration And Curing Complete, Including Reinforcement Steel As Per Design; Providing Internal And External Plastering In Cement Mortar Of Required Thickness, Smooth Finishing, And Curing; Providing Flooring With Cement Concrete Or Ips Finish, Including Base Preparation And Finishing; Supplying And Fixing Of Ms/Steel Door With Frame, Including Holdfasts, Hinges, Locking Arrangement And Painting; Providing Ventilators With Ms Grill, Including Fixing; Complete Internal And External Painting/Whitewashing With Approved Quality Paint; Providing Necessary Provisions For Meter Installation Such As Cable Entry Points, Sleeves, Earthing Arrangement, Foundation Bolts And Fixtures; The Scope Includes Cost Of All Materials Such As Bricks, Cement, Sand, Aggregates, Steel, Doors, Grills, Paint, Water, Etc., And All Labour, Tools & Plants (T&P), Scaffolding, Curing, Carriage, Loading/Unloading, Handling And All Incidental Works Required For Complete Construction As Per Standard Specifications And Direction Of Engineer-In-Charge. , Laying Of Power/Control Cable Of Specified Size In Trench/Duct/On Surface Along Approved Route, Including Excavation Of Trench, Sand Cushioning, Proper Dressing, Alignment, Clamping, Identification Tagging, Protective Covering With Bricks/Tiles (Where Required), Backfilling, Ramming, Leveling, And Disposal Of Surplus Earth; Including Handling, Shifting, Straightening, And Pulling Of Cable With Due Care To Avoid Damage And Maintain Required Bending Radius; Complete In All Respects As Per Standard Specifications And Direction Of Engineer-In-Charge, All Materials, Tools & Plants (T&P), Equipment And Tackles Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing Services For Cutting/Trimming Of Trees And Branches Interfering With Lt/Ht Electrical Lines, Including Clearance Of Vegetation For Safe Operation And Maintenance Of Lines, Complete In All Respects As Per Departmental Standards And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Machinery, Safety Arrangements, Cutting, Stacking And Disposal Of Cut Material, Protection Of Existing Utilities, Obtaining Necessary Permissions From Concerned Authorities, And All Allied Works Required For Proper Completion Of The Work As Per Directions Of The Engineer-In-Charge. , Safe Dismantling Of Existing/Old Electrical Materials At Site, Including Careful Removal Without Damage To Reusable Items, And Carriage Of Dismantled Materials From Site Of Work To Electricity Store Centre, Hapur, With Loading And Unloading At Both Ends Over Kachha And Pakka Roads, Strictly As Per Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Transportation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge.
|