Tender for Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Stay Wire 7/10 Swg , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , 11 Kv completion Poly. Disc Insulator 45 Kn , Stay Set 16X1800 , M.S. Angle 65X65x6 Mm , Acsr Dog Conductor , A.B.Cab. L.T. (3X120)+ (1X95)+(1X16) Sq.Mm , Earth Rod 2540X20 Mm , 11 Kv V-Type Steel Cross Arm 65X65x6 Mm , 11 Kv Composite Polymer Pin Insulator , D.O Fuse Set 11 Kv , Acsr Weasel Conductor , Ms Channel 100X50 Mm , 11 Kv Tpmo , Lt Abc 3X50+1X35+1X16 Sq.Mm , G.I. Wire 6 Swg , Disc Fitting 45 Kn (T&C) , Gi Wire 4Mm/ 8 Swg , Abc (3X95+1X70+1X16)Sq.Mm , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 11 Kv Cable Box O/D 3X120 Xlpe , 11 Kv Cable H.T. Xlpe 3X120 Sq.Mm , 11 Kv H.T.Xlpe Cable 3X185sq.Mm , 11 Kv Cable Box O/D 3X185sq.Mm , Aluminium Cable 1X240 , 11 Kv Cable Box I/D 3X185sq.Mm , 11 Kv Tvm Category C , 11 Kv Ct/Pt Ctr 10/5Amp , 11 Kv Met. Cub. Pilfer Proof Ctr 10/5Amp , Erection And Fixing Of The Following Materials As Per Relevant Respo/Departmental Norms And Specifications, Including Proper Installation, Alignment, Tightening, And Commissioning At Site. The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , Stay Wire 7/10 Swg , 11 Kv completion Poly. Disc Insulator 45 Kn , M.S. Angle 65X65x6 Mm , 11 Kv V-Type Steel Cross Arm 65X65x6 Mm , Ms Channel 100X50 Mm , 11 Kv Composite Polymer Pin Insulator , Lt Abc 3X50+1X35+1X16 Sq.Mm , Disc Fitting 45 Kn (T&C) , Abc (3X95+1X70+1X16)Sq.Mm , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 11 Kv Cable Box O/D 3X120 Xlpe , 11 Kv Cable Box O/D 3X185sq.Mm , Aluminium Cable 1X240 , 11 Kv Cable Box I/D 3X185sq.Mm , 11 Kv Tvm Category C , 11 Kv Ct/Pt Ctr 10/5Amp , 11 Kv Met. Cub. Pilfer Proof Ctr 10/5Amp , Erection Of 11 Mtr Double Pole Structure For 11 Kv Line Including Excavation Of Suitable Size Pits, Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 11 Kv Pin Insulators With Pins, Disc Insulators With Complete Fittings, Etc., Strictly As Per Respo Drawings/Standard Norms; Providing And Fixing Of All Necessary Clamps Made Of M.S. Flat 50×6 Mm With Suitable Nuts & Bolts, Stone Pad, Jumpering, Alignment, Tightening And All Allied Works; The Scope Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , Erection And Fixing Of Single Pole Structure For Lt Line Including Excavation Of Suitable Size Pits, Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Stone Pad, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , Grouting Of St/Pcc Supports In cement concrete 1:3:6 (Cement, Sand & 40 Mm Brick Ballast) In Block Size 450×450 Mm Up To 1/6Th Depth Of Full Length Of Support Below Ground Level And 300 Mm Above Ground Level (Plinth), Using cement concrete 1:3:6 (Cement, Coarse Sand And Stone Grit) Including Mufting As Per Approved Drawing; The Work Shall Include Excavation, Backfilling, Proper Ramming, And Curing Complete In All Respects With All Required Materials; The Scope Further Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Executing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , Safe Dismantling, Loading, Transportation, Unloading, Re-Erection, Testing And Commissioning Of 25/63/100 Kva Distribution Transformers Of 11/0.4 Kv Rating, Including Complete Shifting From Existing Location To New Site As Per Departmental Instructions; The Scope Of Work Shall Include Disconnection Of Ht/Lt Lines, Removal And Refixing Of All Associated Technical Accessories Such As Go Switch Set, Drop Out Fuses, Lightning Arrestors, Ht/Lt Bushings, Earthing Arrangements, Breather, Conservator Connections, Oil Level Indicators, Silica Gel, Protection Devices And All Allied Fittings; Proper Handling Using Suitable Capacity Crane/Chain Pulley Block, Providing Required T&P, Skilled Labour, Safety Measures To Avoid Any Mechanical/Electrical Damage, Checking Of Transformer Oil Level And Filtration If Required, Tightening Of All Connections, Re-Alignment, Replacement Of Minor Damaged Components, And Ensuring Proper Earthing And Guarding; Including Carriage Of Transformer And Accessories On Suitable Vehicle Over All Types Of Roads, Complete Installation On Plinth/Structure, Connection With Existing Network, Testing Of Ir Value, Ratio Test And Trial Run For Satisfactory Operation, Strictly As Per Relevant Standards And Direction Of Engineer-In-Charge; The Rate Shall Be Inclusive Of All Labour, Tools & Plants, Transportation, Insurance, Loading-Unloading, And Incidental Charges Required To Complete The Work In All Respects. , 25 Kva Transformer On Double Pole , 63 Kva Transformer On Double Pole , 100 Kva Transformer On Double Pole , Complete Earthing System For 25 Kva, 63 Kva And 100 Kva Distribution Transformers, Comprising Of Supply And Installation Of Suitable Size G.I./Copper Earth Electrodes (Pipe/Rod Type Of Standard Length) Driven Or Installed In Earth Pit Of Required Dimensions, Including Excavation And Backfilling With Layers Of Charcoal/Coke And Common Salt, Watering Arrangement With G.I. Pipe And Funnel With Wire Mesh, And Construction Of Brick Masonry Chamber With Ci/Rcc Cover; Providing And Laying Of G.I. Strip/Wire Of Required Size From Transformer Body, Neutral And Lightning Arrester (If Applicable) To Earth Electrode, Including All Connections With Nuts, Bolts, Washers, Lugs And Proper Clamping, Testing Of Earth Resistance And Ensuring Value Within Permissible Limits As Per Relevant Standards; The Scope Includes All Materials Such As G.I. Pipe/Rod, G.I. Strip/Wire, Charcoal, Salt, Bricks, Cement, Sand, Ci/Rcc Cover, Etc., And All Labour, Excavation, Refilling, Watering, Transportation, Handling, Testing, And All Tools & Plants (T&P) Required For Complete And Satisfactory Installation As Per Respo/Standard Specifications And Direction Of Engineer-In-Charge. , Erection And Fixing Of 11 Kv D.O. Fuse Set On St/Pcc Pole Including Mounting/Fixing Materials, Clamps, Nuts & Bolts, And Accessories Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Fuse Set Shall Be Supplied By The Department; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements, And All Allied Works Provided By Contractor As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Erection And Fixing Of 11 Kv Tpmo Set On St/Pcc Pole Including Mounting/Fixing Materials, Clamps, Nuts & Bolts, And Accessories Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Tpmo Set Shall Be Supplied By The Department; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements, And All Allied Works Provided By Contractor As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying And Stringing Of Overhead 11 Kv Ht Xlpe Cable (3×120 Sq.Mm) On St/Pcc Poles, Including Proper Hanging And Fixing Of Cable With Necessary Clamps, Supports, Nuts & Bolts (To Be Arranged By The Contractor), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Lifting, Installation, Alignment, Tightening, Safety Arrangements, And All Allied Works Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site, And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying And Stringing Of Lt Aerial Bunched Cable (Abc) (3×120 + 1×95 + 1×16 Sq.Mm) On St/Pcc Poles, Including Proper Hanging, Dressing And Fixing Of Cable With Necessary Clamps, Supports, Nuts & Bolts (To Be Arranged By The Contractor), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Lifting, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Laying Of 140 Mm Dia (O/D) Pn-4, Pe-80 Grade, Uv Stabilized Hdpe Pipe In Standard Lengths (6 M Each) By Trenchless/Drilling Method For Laying Of Underground 11 Kv Cable, Complete In All Respects As Per Relevant Is Specifications And Directions Of The Site In-Charge; The Scope Of Work Includes Formation Of Entry And Exit Pits, Drilling With Suitable Machinery And Drilling Fluid, Alignment, Jointing, Insertion Of Pipe, Protection Of Existing Utilities, And Complete Site Restoration; The Work Also Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Materials, Safety Arrangements And All Allied Works Required For Proper Execution; The Contractor Shall Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying Of 11 Kv Ht Xlpe Cable Of Size 3×185 Sq.Mm Underground Through Hdpe Pipe, Including Pulling, Proper Dressing And Positioning Of Cable, Leaving Adequate Spare Cable In Loop Shape At Both Ends As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Cable Pulling Equipment, Alignment, Safety Arrangements And All Allied Works Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , 11 Kv Ht Xlpe Cable Of Size 3×185 Sq.Mm , 11 Kv Ht Xlpe Cable Of Size 3×120 Sq.Mm , Fabrication Of Guarding Angle Other Requisites Material For Guarding By Drawing 02Nos G.I Wire And Making Loop At Suitable Distance As Per Respo Drawing/Norms By Providing Holding Clamps, 02Nos. Eye Bolts Made Of M.S. Round Size 12Mm Dia-100Mm Long & Cross Arm Clamps Made Of M.S. Flat Of Size 50X6mm And Bolts As Per Norms Of Respo Norms, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. As Per Direction Of Site Incharge. (Only Guarding Angle & Gi Wire Will Be Provided By Department). , G.I. Wire 6 Swg , G.I. Wire 4Mm/ 8 Swg , Grouting & Fixing Of Stay Rods (16X1800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing & Fixing Of G.I. Pipe 6Dia Class-B Over 11Kv/33 Kv Xlpe Cable Before Mounting The Cable At Double Pole. The Work Includes Fitting Of Clamps, Sealing Of Top And Bottom Of Pipe And One End Of Pipe Is To Be Burried Under Earth About 500Mm Earch Including Mounting And Clamping The Cable On Double Pole Structure And Making Connection With Overhead Line At Both Ends, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Insulation Piercing Connector (Ipc) Complete In All Respects, Including Proper Installation, Tightening And Ensuring Safe And Reliable Connection, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of All Types Of Clamps Including F-Type Clamps, Holding Clamps, Cross-Arm Clamps, Lt Clamps, Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , F-Clamp , Holding Clamp With Nut Bolt , Dead & Clamp , Lt Clamp , X Arm Holding Clamp , Providing And Fixing Of Nut & Bolts As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Lt Insulators Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Lt Fuse Box Complete In All Respects, Including Proper Mounting, Connection, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Lt Fuse Set Complete In All Respects, Including Proper Mounting, Connection, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Eye Hook Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of J Hook Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying, Stringing And Final Sagging Of Acsr Weasel Conductor Complete In All Respects, Including Proper Tensioning, Alignment And Dressing Of Conductor Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Use Of Stringing Equipment, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying, Stringing And Final Sagging Of Acsr Dog Conductor Complete In All Respects, Including Proper Tensioning, Alignment And Dressing Of Conductor Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Use Of Stringing Equipment, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Installation Of Maintenance-Free, Multifaceted, Corrosion-Resistant Chemical Earthing Electrode Of Size 80 Mm Dia × 3000 Mm Length, Complete With 50 Kg Backfill Compound And All Required Accessories For Body/Neutral Earthing Of Transformers, Including Providing And Fixing Of M.S. Earth Strip For Connection (The Strip To Be Properly Welded To The Earthing Electrode And Neutral Support), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Excavation, Installation, Welding, Connection, Testing, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Jumpering Of Lt/Ht Lines For Proper Energization, Including Cutting, Dressing, Binding And Fixing Of Jumpers With Suitable Connectors/Clamps, Ensuring Proper Electrical Continuity And Safety, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing Services For Cutting/Trimming Of Trees And Branches Interfering With Lt/Ht Electrical Lines, Including Clearance Of Vegetation For Safe Operation And Maintenance Of Lines, Complete In All Respects As Per Departmental Standards And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Machinery, Safety Arrangements, Cutting, Stacking And Disposal Of Cut Material, Protection Of Existing Utilities, Obtaining Necessary Permissions From Concerned Authorities, And All Allied Works Required For Proper Completion Of The Work As Per Directions Of The Engineer-In-Charge. , Safe Dismantling Of Existing/Old Electrical Materials At Site, Including Careful Removal Without Damage To Reusable Items, And Carriage Of Dismantled Materials From Site Of Work To Electricity Store Centre, Hapur, With Loading And Unloading At Both Ends Over Kachha And Pakka Roads, Strictly As Per Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Transportation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge.
|