|
Tender for 2X800 Mw Ntpc Singrauli Stpp Stage - Iii Boq-Cum-Price Schedule For Lt Switchgear Nit No. , Dated 02.052026 Bidder Name:- S.No. Item No. Item Name Uom Total Qty. Rating (A) Board No. Unit Price (Ex-Works) Rs. Total Price (Ex-Works) Rs. Freight % In W.R.T Total Ex- Works (In %) Freight Amount (Rs.) Total Price (Exworks + Freight) (Rs.) Gst@18% On Ex-Works + Freight (Rs.) Total For Site Price (Rs.) No. Of Plain Cement Concrete / Acb Panel No. Of Mcc / Acdb / Dcdb Panel Board Name Plate, Description & Rating , 506-0110316-00-A , 506-0110040-00-A , 506-0110382-00-A , 506-0110107-00-A , 506-0110092-00-A , 506-0110419-00-A , 506-0110387-00-A , 506-0110321-00-A , 506-0110300-00-A , 506-0110317-00-A , 506-0110041-00-A , 506-0110383-00-A , 506-0110108-00-A , 506-0110093-00-A , 506-0110420-00-A , 506-0110388-00-A , 506-0110322-00-A , 506-0110301-00-A , 506-0110179-00-A , 506-0110180-00-A , 506-0110181-00-A , 506-0110182-00-A , 506-0110183-00-A , 506-0110170-00-A , 506-0110165-00-A , 506-0110171-00-A , 506-0110166-00-A , 506-0110264-00-A , 506-0110077-00-A , 506-0110331-00-A , 506-0110241-00-A , 506-0110079-00-A , 506-0110983-00-A , 506-0110265-00-A , 506-0110332-00-A , 506-0110242-00-A , 506-0110080-00-A , 506-0110984-00-A , 506-0110162-00-A , 506-0110142-00-A , 506-0110259-00-A , 506-0110339-00-A , 506-0110184-00-A , 506-0110254-00-A , 506-0111020-00-A , 506-0111019-00-A , 506-0111032-00-A , 506-0110251-00-A , 506-0110044-00-A , 506-0111033-00-A , 506-0111035-00-A , 506-0110190-00-A , 506-0111024-00-A , 506-0111025-00-A , 506-0111026-00-A , 506-0111021-00-A , 506-0111022-00-A , 506-0111034-00-A , 506-0110977-00-A , 506-0110404-00-A , 506-0110411-00-A , 506-0111030-00-A , 506-0111031-00-A , 506-0110412-00-A , 506-0110985-00-A , 506-0110986-00-A , 506-0110417-00-A , 506-0111006-00-A , 506-0110991-00-A , 506-0111007-00-C , 506-0110282-00-A , 506-0110991-00-A , 506-0110989-00-A , 506-0110000-00-B , Grand Total (Evaluation Price Shall Be Exworks + Freight) Notes: , To Calculate The Switchboard Prices, Refer Detailed Board Wise Bom And Module Wise Bom, Annexure-A.1 And Annexure-A.2 Of Technical Data Part-A Of Technical Specification (Pe-Ts-512-506-E002) Respectively. , Bidder Has To Quote For The Following Along With The Bid: I) Hmi System: As Per List In Annexure-A Ii) Networking Hardware For Numerical Relays, Imc As Per List In Annexure-B1 & For Wireless Temperature Monitoring System As Per List In Annexure-B3 Iii) annual maintenance contract For Numerical Relays As Per Annexure-B2 Iv) Numerical Relay, Imcc, Wireless Temperature Monitoring & Hmi System Commissioning: As Per Annexure-C V) Tools & Tackles: As Per Annexure-D Vi) Site Modification Charges: As Per Annexure-E Vii) E & C Spares: As Per Annexure-F Viii) Mandatory Spare: As Per List In Annexure-G Ix) Bidder To Provide A Schedule Of Unit Prices In Accordance With The List Provided In Annexure-H , Bidder To Ensure That Summation Of Prices (As Per Annexure-H) Of Applicable Modules (As Per Annexure A.1-Boardwise Bom) And Applicable Panels (Mentioned Above By The Bidder) Of A Board Shall Be Equivalent To Board Price Quoted Above For That Board. Variation Of +/- 5% Is Acceptable In The Derived Price From The Board Price Quoted Above. , Addition/ Deletion Of Quantities Shall Be Applicalbe At The Quoted Prices. Allowable Variation In Quantity And Price Shall Be As Per Nit. , All Lt Pcc/ Pmcc/Mcc/ Dbs Shall Be Supplied Alongwith The Integral Base Frames, Foundation Bolts, Cable Glands & Lugs. Prices For The Same Shall Be Built In The Switchboard Price. , Bidder Is Required To Provide The Quantity Of Panels Corresponding To Each Board In The Table Above When Submitting Their Techno-Commercial Proposal. , In Case Module Doors Are Part Of Modules, 2 Nos Of Dummy Modules Of Each Size To Fill In Module Being Taken Out For Maintenance Purpose Shall Be Provided In Each Switchgear Room (Refer Annexure-3_Tentative Switchgear Location Of Technical Specification Pe-Ts-512-506-E002), These Dummy Modules Shall Be Fitted In Switchboard As Vacant Modules Having No Cut Out On Back Side And Cable Alley Side. In Case Door Is Hinged To The Panel, 2 Nos Of Blanking Plates Of Each Size Need To Be Provided. Prices For The Same Shall Be Built In The Switchboard Price. , No Additional Prices Shall Be Paid For Prototype Panels, Prices Quoted Above Includes Cost Of Prototype Panels Also. , Pvc Shall Be Applicable For This Enquiry For Pmcc / Plain Cement Concrete / Mcc / Acbd / Dcdb Only) As Per Ieema Circular (Https://Ieema.Org/Wp-Content/Uploads/2020/07/Lvswgr-Jan-2019.Pdf) .Price Variation Is Not Applicable For Ac Mccb Box; Dc Mccb Box; Hmi System; Numerical Relay, Imcc And Wireless Temp Monitoring System- Networking Hardware; annual maintenance contract For Numerical Relay; Numerical Relay, Imcc, Wireless Temp Monitoring And Hmi System- Commissioning; Tools & Tackle; Site Modification; E & C Spares & Mandatory Spares. , In Unit Addition-Deletion Prices (Annexure-H), Prices Quoted For Components Shall Be Reasonable And As Per List Price Of Concerned Manufacturers. Annexure-A Hmi System S. No. Item Description Qty. Unit Unit Price (Ex-Works) Rs. Total Price (Ex-Works) Rs. Freight % In W.R.T Total Ex- Works (In %) Freight Amount (Rs.) Total Price (Exworks + Freight) (Rs.) Gst@18% On Ex-Works + Freight (Rs.) Total For Site Price (Rs.) Remarks Complete Design, Engineering & Supply Of The Following Items : , Hmi (Ews) , Console For Hmi , Laser Printer (A4 Size) , Table For Printer , Total Of Annexure A Note: , Refer Annexure-1_Typical Switchgear Relay Network Architecture. , Industrial Modular Design Console (Furniture I.E. Table With Drawer & Swivel Computer Chair) Shall Be Provided. Each Console Shall Have Space For Keeping An Additional Pc. , Make And Color Shade Of Furniture Shall Be Decided During Detail Engineering. Furniture Color Shade Should Match With Control Room Furniture. , Bhel Will Provide Ups Redundant Feeder At One Location Near To Ews Location. Further Distribution Of Ups Supply (For Hmi, Network Switch Etc.) Along With Ups Db Shall Be In The Scope Of Bidder. , For Testing And Erection & Commissioning Charges For Hmi- Items, Kindly Refer S.No.4 Of Annexure-C. . Annexure-B1 Networking Hardware For Numerical Relay & Imcc S. No. Item Description Qty. Unit Unit Price (Ex-Works) Rs. Total Price (Ex-Works) Rs. Freight % In W.R.T Total Ex- Works (In %) Freight Amount (Rs.) Total Price (Exworks + Freight) (Rs.) Gst@18% On Ex-Works + Freight (Rs.) Total For Site Price (Rs.) Remarks , Ethernet Switch With Iec-61850 Protocol , Network Level Ethernet Switch (Of Adequate Ports) , Cat5e/Cat6 Or Better Ethernet Cable , Simplex Fiber Optical Cable For Communication Between Swgr Level Ethernet Switchs (& Their Rings) & Network Level Ethernet Switch , Hdpe Conduit (Rodent Free) , Fo Termination Accessories At Bidders Supplied Equipment End Under This Package , Laptop Pc With Licenced Version Software, Hardware For Relay, Imc Parameterisation , Interface Cable With Suitable Connecting Port At Both End For Connection Of Numerical Relay Front Port To The Laptop , Interface Cable With Suitable Connecting Port At Both End For Connection Of Imcc Front Port To The Laptop , Total Of Annexure B1 Notes: , Refer Annexure- 3_Tentative Switchboard Location Detail For Distance Between Switchgear And Network Level Ethernet Switch In Main Control Room. , Refer Annexure- 1_Typical Switchgear Relay Network Architecture For Hmi Requirement. , Bidder To Provide One No. Of Each Type Of Imcc Module Along With Y-Link To Bhel On Returnable Basis & Coordinate With Bhel For Conducting Fat For Imcc As Per Customer Satisfaction. Annexure-B2 annual maintenance contract For Numerical Relay S. No. Item Description Qty. Unit Unit Price (Ex-Works) Rs. Total Price (Ex-Works) Rs. Gst@18% On Ex-Works (Rs.) Total For Site Price (Rs.) Remarks , annual maintenance contract For 3 Years For Following : - Numerical Relays (With Iec 61850) In All Lv Switchgears - Iec 61850 Ethernet Switches In Switchgear Panels - Cat5e Ethernet Cable / Fo Cable/ Optical Fibre Cable With Fire Retardant Outer Sheath - Optical Fibre Cable Termination Equipment Such As Liu, Patch Cord Etc. For Complete Network - Laptops - Hmi Stations (Engineering Work Stations And Printers) - All Other Equipment Required To Meet The Intended Specification , 1St Year , 2Nd Year , 3Rd Year , Total Of Annexure B2 Notes: , The Commencement Date For annual maintenance contract Will Be From The Date Of Takeover By The End Customer. However, Tentative Date Of annual maintenance contract Commencement Shall Be 05.05.2028. Annexure-B3 Networking Hardware For Wireless Temperature Monitoring Sensor S. No. Item Description Qty. Unit Unit Price (Ex-Works) Rs. Total Price (Ex-Works) Rs. Freight % In W.R.T Total Ex- Works (In %) Freight Amount (Rs.) Total Price (Exworks + Freight) (Rs.) Gst@18% On Ex-Works + Freight (Rs.) Total For Site Price (Rs.) Remarks 1.A Complete Networking Hardware(Except Cable & Termination Accessories) Near Switchgear End For Communication Between Wireless Temperature Receiver End & Ddcmis/Hmi For Temperature Monitoring System :- For Two Set Of Switchboards- A. First Set- 8Da, 8Db & 8Dg B. Second Set- 9Da, 9Db & 9Dg 2.0 Set 0.0 0.0 0.0 0.0 0.0 Including Complete Design, Engineering And Supply. 1 Set Is For Each Unit (Consists Of 3 Switchboards) 1.B Special Cable(Twisted Pair/Cat/Optical Fibre Cable Or As Applicable) Including Termination Accessories For Communication Between Switchgear & Ddcmis/Hmi For Temperature Monitoring System :- For Two Set Of Switchboards- A. First Set- 8Da, 8Db & 8Dg B. Second Set- 9Da, 9Db & 9Dg 2.0 Set 0.0 0.0 0.0 0.0 0.0 Including Complete Design, Engineering And Supply. 1 Set Is For Each Unit (Consists Of 3 Switchboards) 2.A Complete Networking Hardware(Except Cable & Termination Accessories) Near Switchgear End For Communication Between Wireless Temperature Receiver End & Ddcmis/Hmi For Temperature Monitoring System :- For Two Set Of Switchboards- A. First Set- 0Da B. Second Set- 0Db 2.0 Set 0.0 0.0 0.0 0.0 0.0 Including Complete Design, Engineering And Supply. 1 Set Is For Each Unit (Consists Of 1 Switchboard) 2.B Special Cable(Twisted Pair/Cat/Optical Fibre Cable Or As Applicable) Including Termination Accessories For Communication Between Switchgear & Ddcmis/Hmi For Temperature Monitoring System :- For Two Set Of Switchboards- A. First Set- 0Da B. Second Set- 0Db 2.0 Set 0.0 0.0 0.0 0.0 0.0 Including Complete Design, Engineering And Supply. 1 Set Is For Each Unit (Consists Of 1 Switchboard) Total Of Annexure B3 0.0 0.0 0.0 0.0 0.0 Notes: , Refer Annexure- 3_Tentative Switchboard Loaction Detail For Distance Between Switchgear And Main Control Room. , For Above Items Listed At S.No.1.A And 1.B, Bmcc(8Da), Tmcc (8Db) And Emcc(8Dg) Of One Unit Is Considered As 1 Set Annexure-C Numerical Relay, Imcc, Wireless Temperature Monitoring & Hmi Systems - Commissioning Charges S. No. Item Description Qty. Unit Unit Price (Ex-Works) Rs. Total Price (Ex-Works) Rs. Gst@18% On Ex-Works (Rs.) Total For Site Price (Rs.) Remarks , Lump Sum All Inclusive Charges Per Numerical Relay Commissioning (Including Conveyance To Site, Boarding And Lodging) , Lump Sum All Inclusive Charges Per Imc Commissioning (Including Conveyance To Site, Boarding And Lodging) 3.A Lump Sum All Inclusive Charges For Wireless Temperature Monitoring System Commissioning. For Two Lot Of Switchboards- A. First Lot- 8Da, 8Db & 8Dg Switchboards B. Second Lot- 9Da, 9Db & 9Dg Switchboards 2.0 Lot 0.0 0.0 0.0 1 Lot Is For Each Unit (Consists Of 3 Switchboard). Refer Note No.3A & 4A 3.B Lump Sum All Inclusive Charges For Wireless Temperature Monitoring System Commissioning. For Two Lot Of Switchboards- A. First Lot- 0Da Switchboard B. Second Lot- 0Db Switchboard 2.0 Lot 0.0 0.0 0.0 1 Lot Is For Each Unit (Consists Of 1 Switchboard). Refer Note No.3B & 4B , Testing And Erection & Commissioning Charges For Hmi- Items At Sl. No. 1-4 Of Annexure-A , Total Of Annexure C Notes: , Amount Payable For Numerical Relay Commissioning = Unit Price For Commissioning Charges As Per Sl.No.1 Above X No. Of Relays Commissioned (Same To Be Certified By Bhel). , Amount Payable For Imcc Commissioning = Unit Price For Commissioning Charges As Per Sl.No.2 Above X No. Of Imcc Commissioned (Same To Be Certified By Bhel). 3.A Amount Payable For Wireless Temperature Monitoring System Commissioning For Each Unit (Bmcc, Tmcc And Emcc) = Unit Price For Commissioning Charges As Per Sl.No.3.A Above (Same To Be Certified By Bhel). 3.B Amount Payable For Wireless Temperature Monitoring System Commissioning For Each Unit (Station Service Switchboard) = Unit Price For Commissioning Charges As Per Sl.No.3.B Above (Same To Be Certified By Bhel). 4.A For Line Item 3.A, Testing And Commissioning Of Wireless Temperature Monitoring System For Bmcc(8Da), Tmcc (8Db) And Emcc(8Dg) Of One Unit Is Considered As 1 Lot, Similarly 3 Boards Of Another Unit For 2Nd Lot. 4.B For Line Item 3.B, Testing And Commissioning Of Wireless Temperature Monitoring System For Station Service Switchboard (0Da) Of One Unit Is Considered As 1 Lot, Similarly 1 Board Of Another Unit For 2Nd Lot. , Approximately 15 Nos. Of Numerical Relays And/Or 50 Nos. Of Imcs Can Be Considered By Bidder For Commissioning In Each Visit. , For Line Item 1, 2, 3.A & 3.B, Bidder To Note That Testing, Configuration And Networking Setup Of Relay, Imc & Temperature Monitoring System Shall Be The BidderS Responsibility Completely. , For Line Item 4, Bidder To Note That Erection & Commissioning, Testing, Configuration And Networking Setup Of Hmi System Shall Be The BidderS Responsibility Completely. , Bidder To Coordinate With Dcs Suppplier (Bhel Edn) To Ensure Smooth And Effective Communication Between Numerical Relay/ Y-Link And Dcs, As Well As Between Temperature Monitoring System And Dcs/Hmi. , For Line Items 1 To 4, Bidder To Depute Its Manpower Within 15 Days From The Date Of Intimation By Bhel. Annexure-D Tools & Tackles S. No. Item Description Quantity Unit Unit Price (Ex-Works) Rs. Total Price (Ex-Works) Rs. Freight % In W.R.T Total Ex- Works (In %) Freight Amount (Rs.) Total Price (Exworks + Freight) (Rs.) Gst@18% On Ex-Works + Freight (Rs.) Total For Site Price (Rs.) Remarks , Acb Racking Handle , Telescopic Trolly (Trolley For Acb Handling) , Door Key , Relay Test Equipment , Module Racking Handle , Total Of Anenxure -D Notes: , Bidder Has To Quote For Tools And Tackles Mentioned Above. However, Bidder Has To Indicate Any Special Tools (If Required). Annexure-E Site Modification Charges S. No. Item Description Quantity Unit Unit Price (Ex-Works) Rs. Total Price (Ex-Works) Rs. Gst@18% On Ex-Works (Rs.) Total For Site Price (Rs.) , Lump Sum All Inclusive Charges Per Visit For Skilled Technician (Except Daily Charges) , Lump Sum All Inclusive Daily Charges For Skilled Technician , Lump Sum All Inclusive Charges Per Visit For Service Engineer (Except Daily Charges) , Lump Sum All Inclusive Daily Charges For Service Engineer , Site Modification Material @ 1% Of Total Board Cost (I.E. Summation Of S.No. 1 To S.No. 64 Of Boq Cum Price Schedule) , Total Of Annexure E Notes: , Amount Payable For Skilled Technician Per Visit To Site = Visit Charges As Per Sl. No. 1 Above + (Daily Charges As Per Sl. No. 2 Above X No. Of Days At Site) (To Be Certified By Bhel Site) , Amount Payable For Service Engineer Per Visit To Site = Visit Charges As Per Sl. No. 3 Above + (Daily Charges As Per Sl. No. 4 Above X No. Of Days At Site) (To Be Certified By Bhel Site) , Amount Payable For Site Modification Material Shall Be Based On The Actual Cost Of The Materials Utilized. (To Be Certified By Bhel Site). The Cost Of The Actual Materials Used Will Be Determined Using The Unit Rate Provided By The Bidder In The Annexure-H. , For Line Items 1 To 4, Bidder To Depute Its Manpower Within 15 Days From The Date Of Intimation By Bhel. Annexure-F E&C Spares S. No. Item / Component Qty. Unit Unit Price (Ex-Works) Rs. Total Price (Ex-Works) Rs. Freight % In W.R.T Total Ex- Works (In %) Freight Amount (Rs.) Total Price (Exworks + Freight) (Rs.) Gst@18% On Ex-Works + Freight (Rs.) Total For Site Price (Rs.) , Factory Built Assemblies (Pcc/Mcc/Db) , Busbar Supports (Horizontal) , Primary Isolating Contacts (Bus Side) Of Each Rating , Primary Isolating Contacts (Load Side) Of Each Rating , Secondary Isolating Contacts Of Each Rating , Gaskets (Each Size) , Fixed Terminal (1Way) , Shrouds (For Outgoing Modules) - One For Each Physical Size Of Module 1.8.A. Wire (For Secondary Wiring)-2.5 Mm2 100.0 Metres 0.0 0.0 0.0 0.0 0.0 1.8.B. Wire (For Secondary Wiring)-1.5Mm2 100.0 Metres 0.0 0.0 0.0 0.0 0.0 , Lugs (For Secondary Wiring) , Air Circuit Breaker (For Each Rating) , Shunt Trip Coil , Spring Charging Motor-1 Motor Of Each Rating , Closing Coil , Auxiliary Switch , Isolating Switch , Main Contact Kit For Each Rating , Power Contactors , Contactor Coil Of Each Rating , Contacts Kit (Main) For Each Rating , Auxiliary Contactors , Complete Unit With 2No + 2Nc Contacts-1 No. Of Each Rating/Type 5.2.A. Contactor Coils-Ac For Each Rating 1.0 Set 0.0 0.0 0.0 0.0 0.0 5.2.B. Contactor Coils-Dc For Each Rating 1.0 Set 0.0 0.0 0.0 0.0 0.0 , Mccb-1 No. Of Each Rating/Type , Mpcb -1 No. Of Each Rating/Type , Mcb-1 No. Of Each Rating/Type , Push Buttons , Actuator Contacts , Element , Indicating Lamps , Complete Unit , Lens (Assorted) , Others , Selector & Control Switch (Each Type) , Connecting Cable Between Ct And Imcc Of Appropriate Length , Connecting Cable Between Vt And Imcc Of Appropriate Length , Imc Display Hmi Cable Of Appropriate Length , Total Of Annexure -F , Complete Breaker Of Each Rating , Numerical Relays Of Each Type , Auxiliary Relays Of Each Type , Horizontal Busbar Support Insulators , Vertical Busbar Dropper Support Insulators , Current Transformer Of Each Type & Ratio , Voltage Transformer Of Each Type & Ratio , Control Supply Transformer Of Each Type & Rating , Power Contactor Of Each Type And Rating , Coil For Above Contactor For Each Type And Rating , Mccbs (Equally Divided For All Ratings) , Mpcbs (Equally Divided For All Ratings) , Closing Coil Of Each Type Of Each Rating , Trip Coil Of Each Type Of Each Rating , Aux Contact Set Of Each Type And Rating , Fixed Contact Set Of Each Type & Rating , Moving Contact Set Of Each Type & Rating , Maintenance Tools And Accessories For Maintenance Of Lt Mcc , Total Of Annexure -G , Incoming Feeder Unit Acb Incomer To Pcc/Pmcc From Trafo. - Module Type Daet (I/C) 1000A 1600A 2000A 2500A 3000A 4000A Acb Incomer To Mcc - Module Type Dae (I/C) 630A 800A 1000A 1250A 1600A 2000A 2500A 3000A 4000A Acb Incomer To Emergency Board - Module Type Dg(I/C) 800A 1000A 1250A 1600A 2000A 2500A 3000A 4000A Mccb Incomer For Mcc / Acdb - Module Type E3 (I/C) 63A - Fixed Type 125A - Fixed Type 160A - Fixed Type 200A - Fixed Type 250A - Fixed Type 300A - Fixed Type 400A - Fixed Type 63A - Drawout Type 125A - Drawout Type 160A - Drawout Type 200A - Drawout Type 250A - Drawout Type 300A - Drawout Type 400A - Drawout Type Mccb Incomer With Contactor Changeover - Module Type cement concrete 16A - Fixed Type 32A - Fixed Type 63A - Fixed Type 125A - Fixed Type 200A - Fixed Type 250A - Fixed Type 300A - Fixed Type 400A - Fixed Type 16A - Drawout Type 32A - Drawout Type 63A - Drawout Type 125A - Drawout Type 200A - Drawout Type 250A - Drawout Type 300A - Drawout Type 400A - Drawout Type 220V Dcdb Incomer From Charger - Module Type Ch (I/C) 50A - Ch Fixed Type 100A - Ch Fixed Type 125A - Ch Fixed Type 150A - Ch Fixed Type 200A - Ch Fixed Type 300A - Ch Fixed Type 400A - Ch Fixed Type 450A - Ch Fixed Type 500A - Ch Fixed Type 630A - Ch Fixed Type 800A - Ch Fixed Type 1000A - Ch Fixed Type 1250A - Ch Fixed Type 1600A - Ch Fixed Type 50A - Ch Drawout Type 100A - Ch Drawout Type 125A - Ch Drawout Type 150A - Ch Drawout Type 200A - Ch Drawout Type 300A - Ch Drawout Type 400A - Ch Drawout Type 450A - Ch Drawout Type 500A - Ch Drawout Type 630A - Ch Drawout Type 800A - Ch Drawout Type 1000A - Ch Drawout Type 1250A - Ch Drawout Type 1600A - Ch Drawout Type 220V Dcdb Incomer From Battery - Module Type Db (I/C) 50A - Db Fixed Type 100A - Db Fixed Type 125A - Db Fixed Type 150A - Db Fixed Type 200A - Db Fixed Type 300A - Db Fixed Type 400A - Db Fixed Type 450A - Db Fixed Type 500A - Db Fixed Type 630A - Db Fixed Type 800A - Db Fixed Type 1000A - Db Fixed Type 1250A - Db Fixed Type 1600A - Db Fixed Type 50A - Db Drawout Type 100A - Db Drawout Type 125A - Db Drawout Type 150A - Db Drawout Type 200A - Db Drawout Type 300A - Db Drawout Type 400A - Db Drawout Type 450A - Db Drawout Type 500A - Db Drawout Type 630A - Db Drawout Type 800A - Db Drawout Type 1000A - Db Drawout Type 1250A - Db Drawout Type 1600A - Db Drawout Type , Buscoupler Unit Acb Buscoupler To Pcc/Pmcc/Mcc - Module Type Daet/ Dae (B/C) 630A 800A 1000A 1250A 1600A 2000A 2500A 3000A 4000A Mccb Buscoupler For Mcc / Acdb - Module Type E3 (B/C) 63A - Fixed Type 125A - Fixed Type 160A - Fixed Type 200A - Fixed Type 250A - Fixed Type 300A - Fixed Type 400A - Fixed Type 63A - Drawout Type 125A - Drawout Type 160A - Drawout Type 200A - Drawout Type 250A - Drawout Type 300A - Drawout Type 400A - Drawout Type 220V Dcdb Buscoupler - Module Type - Dc 50A - Dc Fixed Type 100A - Dc Fixed Type 125A - Dc Fixed Type 150A - Dc Fixed Type 200A - Dc Fixed Type 300A - Dc Fixed Type 400A - Dc Fixed Type 450A - Dc Fixed Type 500A - Dc Fixed Type 630A - Dc Fixed Type 800A - Dc Fixed Type 1000A - Dc Fixed Type 1250A - Dc Fixed Type 1600A - Dc Fixed Type 50A - Dc Drawout Type 100A - Dc Drawout Type 125A - Dc Drawout Type 150A - Dc Drawout Type 200A - Dc Drawout Type 300A - Dc Drawout Type 400A - Dc Drawout Type 450A - Dc Drawout Type 500A - Dc Drawout Type 630A - Dc Drawout Type 800A - Dc Drawout Type 1000A - Dc Drawout Type 1250A - Dc Drawout Type 1600A - Dc Drawout Type 220V Dcdb Tie - Module Type - Hd 50A - Hd Fixed Type 100A - Hd Fixed Type 125A - Hd Fixed Type 150A - Hd Fixed Type 200A - Hd Fixed Type 300A - Hd Fixed Type 400A - Hd Fixed Type 450A - Hd Fixed Type 500A - Hd Fixed Type 630A - Hd Fixed Type 800A - Hd Fixed Type 1000A - Hd Fixed Type 1250A - Hd Fixed Type 1600A - Hd Fixed Type 50A - Hd Drawout Type 100A - Hd Drawout Type 125A - Hd Drawout Type 150A - Hd Drawout Type 200A - Hd Drawout Type 300A - Hd Drawout Type 400A - Hd Drawout Type 450A - Hd Drawout Type 500A - Hd Drawout Type 630A - Hd Drawout Type 800A - Hd Drawout Type 1000A - Hd Drawout Type 1250A - Hd Drawout Type 1600A - Hd Drawout Type , Acb Outgoing Supply Feeder - Module Type Dae (O/G)/Dae-Tie 630A 800A 1000A 1250A 1600A 2000A 2500A 3000A 4000A , Acb Outgoing Motor Feeder - Module Type Dm/Pm/Am (Controlled From Ddcmis/Plc/Atrs) 90- 200Kw , Mccb Outgoing Supply Feeders Module Type E3(O/G) 16A - Fixed Type 32A - Fixed Type 63A - Fixed Type 100A - Fixed Type 125A - Fixed Type 160A - Fixed Type 200A - Fixed Type 250A - Fixed Type 300A - Fixed Type 400A - Fixed Type 16A - Drawout Type 32A - Drawout Type 63A - Drawout Type 100A - Drawout Type 125A - Drawout Type 160A - Drawout Type 200A - Drawout Type 250A - Drawout Type 300A - Drawout Type 400A - Drawout Type Module Type E3-Tp (O/G) 16A - Fixed Type 32A - Fixed Type 63A - Fixed Type 100A - Fixed Type 125A - Fixed Type 160A - Fixed Type 200A - Fixed Type 250A - Fixed Type 300A - Fixed Type 400A - Fixed Type 16A - Drawout Type 32A - Drawout Type 63A - Drawout Type 100A - Drawout Type 125A - Drawout Type 160A - Drawout Type 200A - Drawout Type 250A - Drawout Type 300A - Drawout Type 400A - Drawout Type Module Type Es3 (O/G) 63A - Fixed Type 100A - Fixed Type 125A - Fixed Type 160A - Fixed Type 200A - Fixed Type 250A - Fixed Type 400A - Fixed Type 63A - Drawout Type 100A - Drawout Type 125A - Drawout Type 160A - Drawout Type 200A - Drawout Type 250A - Drawout Type 400A - Drawout Type 2-Ph Feeder Module Type E2(O/G) 100A - Fixed Type 160A - Fixed Type 200A - Fixed Type 250A - Fixed Type 300A - Fixed Type 400A - Fixed Type 100A - Drawout Type 160A - Drawout Type 200A - Drawout Type 250A - Drawout Type 300A - Drawout Type 400A - Drawout Type Double Pole 1-Ph Feeder Module Type E1(O/G) 16A - Fixed Type 32A - Fixed Type 63A - Fixed Type 100A - Fixed Type 125A - Fixed Type 16A - Drawout Type 32A - Drawout Type 63A - Drawout Type 100A - Drawout Type 125A - Drawout Type 3-Ph Mccb Controlled Outgoing Contactor Feeder With Imc Module Type Ea3(O/G) 16A - Fixed Type 32A - Fixed Type 63A - Fixed Type 100A - Fixed Type 125A - Fixed Type 200A - Fixed Type 250A - Fixed Type 400A - Fixed Type 16A - Drawout Type 32A - Drawout Type 63A - Drawout Type 100A - Drawout Type 125A - Drawout Type 200A - Drawout Type 250A - Drawout Type 400A - Drawout Type 3-Ph Mccb Controlled Outgoing Contactor Feeder Without Imc Module Type Et3(O/G) 16A - Fixed Type 32A - Fixed Type 63A - Fixed Type 100A - Fixed Type 125A - Fixed Type 200A - Fixed Type 250A - Fixed Type 400A - Fixed Type 16A - Drawout Type 32A - Drawout Type 63A - Drawout Type 100A - Drawout Type 125A - Drawout Type 200A - Drawout Type 250A - Drawout Type 400A - Drawout Type 1-Ph Mccb Controlled Outgoing Contactor Feeder Module Type Ea1(O/G) 16A - Fixed Type 32A - Fixed Type 63A - Fixed Type 16A - Drawout Type 32A - Drawout Type 63A - Drawout Type 220V Dc Outgoing Mccb Type (X) Feeder 16A - Fixed Type 32A - Fixed Type 63A - Fixed Type 100A - Fixed Type 125A - Fixed Type 200A - Fixed Type 250A - Fixed Type 300A - Fixed Type 400A - Fixed Type 600A - Fixed Type 800A - Fixed Type 16A - Drawout Type 32A - Drawout Type 63A - Drawout Type 100A - Drawout Type 125A - Drawout Type 200A - Drawout Type 250A - Drawout Type 300A - Drawout Type 400A - Drawout Type 600A - Drawout Type 800A - Drawout Type , Dol Motor Starter - Unidirectional Drive - Drawout Type Module Type Dk2 / Pk2 / Ak2 (Controlled From Ddcmis/Plc/Atrs) Upto 5.5Kw 5.6 - 7.0Kw 7.1 - 13Kw 13.1 - 24Kw 24.1 - 29.9Kw Module Type Dk21 / Pk21 / Ak21 (Controlled From Ddcmis/Plc/Atrs) 30.0 - 37.0Kw 37.1 - 55Kw 55.1 - 80.0Kw 80.1 - 89.9Kw Module Type Dk2e/Pk2e/Ak2e (Reacceleration) (Controlled From Ddcmis/Plc/Atrs) Upto 5.5Kw 5.6 - 7.0Kw 7.1 - 13Kw 13.1 - 24Kw 24.1 - 29.9Kw Module Type Dk21e/Pk21e/Ak21e (Reacceleration) (Controlled From Ddcmis/Plc/Atrs) 30.0 - 37.0Kw 37.1 - 55Kw 55.1 - 80.0Kw 80.1 - 89.9Kw Module Type K2 (Controlled From Lcp) Upto 5.5Kw 5.6 - 7.0Kw 7.1 - 13Kw 13.1 - 24Kw 24.1 - 29.9Kw Module Type K21 (Controlled From Lcp) 30.0 - 37.0Kw 37.1 - 55Kw 55.1 - 80.0Kw 80.1 - 89.9Kw Module Type K3 (Controlled From Lpbs) Upto 5.5Kw 5.6 - 7.0Kw 7.1 - 13Kw 13.1 - 24Kw 24.1 - 29.9Kw Module Type K31 (Controlled From Lpbs) 30.0 - 37.0Kw 37.1 - 55Kw 55.1 - 80.0Kw 80.1 - 89.9Kw , Rdol Motor Starter - Bidirectional Drive - Drawout Type Module Type Dn1/ Pn1/ An1 (Controlled From Ddcmis/Plc/Atrs) Upto 5.5Kw 5.6 - 7.0Kw 7.1 - 13Kw 13.1 - 24Kw 24.1 - 29.9Kw 30.0 - 37.0Kw 37.1 - 55Kw 55.1 - 80.0Kw 80.1 - 89.9Kw , ?Rapping Motor (Rm1) Module With Imc , ?Rapping Motor (Rm2) Module With Olr , ?Dust Density Monitor (Ddm) Module , ?Hopper Heater (Hh) Module , ?Support Insulator Heater (Hi) Module , ?Shaft Insulator Heater (Hs) Module , Ash Level Indicator (Ali) Module , Areca Marshaling (Areca) Module , Wave Level Transmitter (Wlt) Module , Marshaling Module For Sspb Of Rapping Motor And Hopper Heater Feedback (Mm) , Wall Blower Module , Lane Road Blower Module , Ah Blower Module , Jamming Relay Module , Wireless Temperature Sensor (Wts1) Module (In One Acb/Pcc Panel With Single Acb) , Wireless Temperature Sensor (Wts2) Module (In One Acb Panel With Double Acb) , Wireless Temperature Sensor (Wts3) Module (In One Double Front Mcc Panel) , Common Auxiliary Module Pt Module Bus Pt Module For Pcc/Pmcc - G1 Type Bus Pt Module For Emergency Mcc - G2 Type Bus Pt Module For Mcc/Acdb - Vm Type Bus Pt Dcdb - S Type 110V Ac Control Supply Module - Type Cs (Consisting Of 415/110V Control Trafo.) 1Kva 2Kva 2.5Kva 3Kva 5Kva 7.5Kva 10Kva 240 V Ac Control Supply Module - Type Cs (Consisting Of 415/240V Control Trafo.) 1Kva 2Kva 2.5Kva 3Kva 5Kva 7.5Kva 10Kva 24V Ac Control Supply Module - Type Cs (Consisting Of 415/24V Control Trafo.) 250Va 500Va 1Kva 2Kva 2.5Kva 3Kva 5Kva 7.5Kva 10Kva 240V Ac Motor Space Heater Module 220V Dc Supply Module (For Receiving 220V Dc Supply) 24V Dc Supply Module 24 V Winding Heating Module Alarm Module Test Supply Module 240 V Ac Panel Space Heating Supply Module - Type Sh (Consisting Of 415/240V Control Trafo.) 1Kva 2Kva 2.5Kva 3Kva 5Kva 7.5Kva 10Kva 240V Ac Space Heater Supply Module- Shs Y-Link , Empty Panel With Horizontal & Vertical Busbar, Support & Auxiliary Busbar (4 Wire System) Plain Cement Concrete Panel (Single Front Drawout Type) Without Temperature Sensor 630 / 630A 1000 / 1000A 1250 / 1250A 1600 / 1600A 2000 / 2000A 2500 / 2500A 3000 / 3000A 4000 / 4000A Mcc Panel (Single Front Fixed Type ) 63 / 63A 250 / 250A 400 / 400A 630 / 630A 800 / 630A 1000 / 630A 1250 / 630A 1600 / 630A 2000 / 630A 2500 / 630A 3000 / 630A 4000 / 630A Mcc Panel (Single Front Drawout Type) 63 / 63A 250 / 250A 400 / 400A 630 / 630A 800 / 630A 1000 / 630A 1250 / 630A 1600 / 630A 2000 / 630A 2500 / 630A 3000 / 630A 4000 / 630A Mcc Panel (Double Front Drawout Type) 63 / 63A 250 / 250A 400 / 400A 630 / 630A 800 / 630A 1000 / 630A 1250 / 630A 1600 / 630A 2000 / 630A 2500 / 630A 3000 / 630A 4000 / 630A Acdb Panel (Double Front Fixed Type) 250 / 250A 400 / 400A 630 / 250A 630 / 630A 220V Dcdb Panel (Single Front Fixed Type) With 20Ka, 1 Second Fault Level Upto 125A (With 125A Vbb) Upto 630A (With 630A Vbb) 1000A (With 630A Vbb) 1600A (With 630A Vbb) 220V Dcdb Panel (Single Front Fixed Type) With 40Ka, 1 Second Fault Level Upto 125A (With 125A Vbb) Upto 630A (With 630A Vbb) 1000A (With 630A Vbb) 1600A (With 630A Vbb) 220V Dcdb Panel (Double Front Fixed Type) With 20Ka, 1 Second Fault Level Upto 125A (With 125A Vbb) Upto 630A (With 630A Vbb) 1000A (With 630A Vbb) 1250A (With 630A Vbb) 1600A (With 630A Vbb) 220V Dcdb Panel (Double Front Fixed Type) With 40Ka, 1 Second Fault Level Upto 125A (With 125A Vbb) Upto 630A (With 630A Vbb) 1000A (With 630A Vbb) 1250A (With 630A Vbb) 1600A (With 630A Vbb) 48V Dcdb Panel (Single Front Fixed Type) Upto 125A (With 125A Vbb) Upto 200A (With 200A Vbb) Upto 630A (With 630A Vbb) 48V Dcdb Panel (Double Front Fixed Type) Upto 125A (With 125A Vbb) Upto 200A (With 200A Vbb) Upto 630A (With 630A Vbb) Empty Acb Panel With Horizontal & Vertical Busbar, Support & Auxiliary Busbar 630 / 630A 800 / 630A 800 / 800A 1000 / 630A 1000 / 800A 1000 / 1000A 1250 / 630A 1250 / 800A 1250 / 1000A 1250 / 1250A 1600 / 630A 1600 / 800A 1600 / 1000A 1600 / 1250A 1600 / 1600A 2000 / 630A 2000 / 800A 2000 / 1000A 2000 / 1250A 2000 / 1600A 2000 / 2000A 2500 / 630A 2500 / 800A 2500 / 1000A 2500 / 1250A 2500 / 1600A 2500 / 2000A 2500 / 2500A 3000 / 630A 3000 / 800A 3000 / 1000A 3000 / 1250A 3000 / 1600A 3000 / 2000A 3000 / 2500A 3000 / 3000A 4000 / 630A 4000 / 800A 4000 / 1000A 4000 / 1250A 4000 / 1600A 4000 / 2000A 4000 / 2500A 4000 / 3000A 4000 / 4000A , Empty Panel With Horizontal & Vertical Busbar, Support & Auxiliary Busbar (3 Wire System) Plain Cement Concrete Panel (Single Front Drawout Type) Without Temperature Sensor 2000 / 2000A 3000 / 3000A Mcc Panel (Double Front Drawout Type) 2000 / 630A 3000 / 630A Acdb Panel (Double Front Fixed Type) 250 / 250A 400 / 400A Empty Acb Panel With Horizontal & Vertical Busbar, Support & Auxiliary Busbar 2000 / 630A 2000 / 800A 2000 / 1000A 2000 / 1250A 2000 / 1600A 2000 / 2000A 3000 / 630A 3000 / 800A 3000 / 1000A 3000 / 1250A 3000 / 1600A 3000 / 2000A 3000 / 2500A 3000 / 3000A , Dummy Panel Upto 630A 800A 1000A 1250A 1600A 2000A 2500A 3000A 4000A , Unit Prices For Circuit Components Air Circuit Breaker Without Releases 630A Acb, 4P, Edo, Ac 800A Acb, 4P, Edo, Ac 1000A Acb, 4P, Edo, Ac 1250A Acb, 4P, Edo, Ac 1600A Acb, 4P, Edo, Ac 2000A Acb, 4P, Edo, Ac 2500A Acb, 4P, Edo, Ac 3000A Acb, 4P, Edo, Ac 4000A Acb, 4P, Edo, Ac 630A Acb, 3P, Edo, Ac 800A Acb, 3P, Edo, Ac 1000A Acb, 3P, Edo, Ac 1250A Acb, 3P, Edo, Ac 1600A Acb, 3P, Edo, Ac 2000A Acb, 3P, Edo, Ac 2500A Acb, 3P, Edo, Ac 3000A Acb, 3P, Edo, Ac 4000A Acb, 3P, Edo, Ac 800A Acb, 2P, Mdo, Dc 1000A Acb, 2P, Mdo, Dc 1250A Acb, 2P, Mdo, Dc 1600A Acb, 2P, Mdo, Dc Mpcb, Short-Circuit Release 16A 25A 32A 63A 80A 115A 150A Tp Mccb, 2No+2Nc Aux, Fsc & O/L Release 16A 25A 32A 63A 100A 125A 160A 200A 250A 315A 400A Tp Mccb, 2No+2Nc Aux, Adj S/C & O/L Release 16A 25A 32A 63A 100A 125A 160A 200A 250A 315A 400A Tp Mccb With Lsig Release 200A 250A 300A 350A 400A Tp Mccb - Motorized With Lsig Release 200A 250A 300A 350A 400A Power Contactor (Ac) ( With 2No & 2Nc Minimum) 16A 25A 32A 63A 80A 115A 150A 185A 265A 315A 400A Power Contactor (Dc) ( With 2No & 2Nc Minimum) 16A 25A 32A 63A 80A 115A 150A 185A 265A 400A Ac Aux. Contactor With 2No + 2Nc 3No + 3Nc 4No + 4Nc 6No + 6Nc Dc Aux. Contactor With 2No + 2Nc 3No + 3Nc 4No + 4Nc 6No + 6Nc Protection Relay Vagm 23 Ctu 12 Ctu 32 Vtt 11 Vag 11 Vaa 11 Vajhm 13 Vajhm 23 Cdgm-12 Cag 12 Cag 34 Ccum 21 Cdg 11 Cdg 31 Cdg 61 Vdg 14 Cdv 62 Cag 14 Vax 31 Cag 37 Caem-21 Vag-21 Vajc-11 Ctmm-501 Motpro Vaa21 Vtt12 Vtig Vtu21 Numerical Relay For Phase Over Current Protection (50/51), Earth Fault Protection (50N/51N), Stand By Earth Fault Protection (51Ns), Restricted Earth Fault Protection (64R), Bus No Volt, Fault Lockout Function (86), Under Voltage With Timer (27M), Synchronising Check Function (25, Circuit Breaker Failure (50Bf), Relay Self Supervision, Circuit Breaker Condition Monitoring, Trip Circuit Supervision (95), Current Tranformer Supervision, Voltage Tranformer Supervision, Breaker Control With I/L, Disturbance Recording, Fault Recording, Event Recording, Measurement Functions (3I, Io, 3U, Uo, Hz, P, Q, E, Pf) Sef Numerical Relay Numerical Relay For Phase Over Current Protection (50/51), Earth Fault Protection (50N/51N), Stand By Earth Fault Protection (51Ns), Restricted Earth Fault Protection (64R), Bus No Volt, Fault Lockout Function (86), Under Voltage With Timer (27M), Synchronising Check Function (25, Circuit Breaker Failure (50Bf), Relay Self Supervision, Circuit Breaker Condition Monitoring, Trip Circuit Supervision (95), Current Tranformer Supervision, Voltage Tranformer Supervision, Breaker Control With I/L, Disturbance Recording, Fault Recording, Event Recording, Measurement Functions (3I, Io, 3U, Uo, Hz, P, Q, E, Pf), Measurement And Display Of Harmonic Contect Of Voltage & Current Numerical Relay For Phase Over Current Protection (50/51), Earth Fault Protection (50N/51N), Bus No Volt, Fault Lockout Function (86), Under Voltage With Timer (27M), Synchronising Check Function (25, Circuit Breaker Failure (50Bf), Relay Self Supervision, Circuit Breaker Condition Monitoring, Trip Circuit Supervision (95), Current Tranformer Supervision, Voltage Tranformer Supervision, Breaker Control With I/L, Disturbance Recording, Fault Recording, Event Recording, Measurement Functions (3I, Io, 3U, Uo, Hz, P, Q, E, Pf) Numerical Relay For Phase Over Current Protection (50/51), Earth Fault Protection (50N/51N), Restricted Earth Fault Protection (64R), Bus No Volt, Fault Lockout Function (86), Under Voltage With Timer (27M), Synchronising Check Function (25, Circuit Breaker Failure (50Bf), Differential Protection (87) (High Impedance), Reverse Power Protection, Dg Neutral Displacement (59), Dg Monitoring, Relay Self Supervision, Circuit Breaker Condition Monitoring, Trip Circuit Supervision (95), Current Tranformer Supervision, Voltage Tranformer Supervision, Breaker Control With I/L, Disturbance Recording, Fault Recording, Event Recording, Measurement Functions (3I, Io, 3U, Uo, Hz, P, Q, E, Pf) Numerical Relay For Phase Over Current Protection (50/51), Earth Fault Protection (50N/51N), Stalling/ Locked Rotor Protection (50L/R), Thermal Overlaod Protection (49), Negative Phase Sequence Protection (46), Bus No Volt, Repetative Start Protection (66), Fault Lockout Function (86), Under Voltage With Timer (27M), Motor Differential Protection (87M), Circuit Breaker Failure (50Bf), Phase Reversal Protection (46R), Current Unbalance Protection, Relay Self Supervision, Circuit Breaker Condition Monitoring, Trip Circuit Supervision (95), Current Tranformer Supervision, Voltage Tranformer Supervision, Breaker Control With I/L, Disturbance Recording, Fault Recording, Event Recording, Measurement Functions (3I, Io, 3U, Uo, Hz, P, Q, E, Pf) Numerical Check Synchronising Relay Check Synchronising Relay Type-Ske11 Or Better Guard Relay Battery Earth Fault Relay, 1-7Ma, Nominal Voltage-220V Dc, 1Dv, 2No special repair Flush Overload Relay, Nominal Voltage-220V Dc, O/V Vltage Setting-110%, 1/4Nv, 1No+1Nc special repair Under Voltage Relay, Nominal Voltage-220V Dc, U/V Setting-80%, Aux..-240V Ac, 1/2Nh, 1No+2Nc special repair Battery Earth Fault Relay, 1-7Ma, Nominal Voltage-48V Dc, 1Dv, 2No special repair Flush Overload Relay, Nominal Voltage-48V Dc, O/V Vltage Setting-110%, 1/4Nv, 1No+1Nc special repair Under Voltage Relay, Nominal Voltage-48V Dc, U/V Setting-80%, Aux..-240V Ac, 1/2Nh, 1No+2Nc special repair Jamming Relay Electronic Type Jamming Relay Imc & Its Modules For Unidirectional Drive , Imc Upto 5.5Kw , Current Sensing Module For Above (If Not Integral In Imc Module) , Imc For 5.6 - 7.0Kw , Current Sensing Module For Above (If Not Integral In Imc Module) , Imc For 7.1 - 13Kw , Current Sensing Module For Above (If Not Integral In Imc Module) , Imc For 13.1 - 24Kw , Current Sensing Module For Above (If Not Integral In Imc Module) , Imc For 24.1 - 29.9Kw , Current Sensing Module For Above (If Not Integral In Imc Module) , Imc For 30.0 - 37.0Kw , Current Sensing Module For Above (If Not Integral In Imc Module) , Voltage Sensing Module For Above (If Not Integral In Imc Module) , Imc For 37.1 - 55Kw , Current Sensing Module For Above (If Not Integral In Imc Module) , Voltage Sensing Module For Above (If Not Integral In Imc Module) , Imc For 55.1 - 80.0Kw , Current Sensing Module For Above (If Not Integral In Imc Module) , Voltage Sensing Module For Above (If Not Integral In Imc Module) , Imc For 80.1 - 89.9Kw , Current Sensing Module For Above (If Not Integral In Imc Module) , Voltage Sensing Module For Above (If Not Integral In Imc Module) , Expansion Module For Imc Timer (Dc) On Delay Timer, 0.5-5Sec., 220V Dc, 2No+2Nc On Delay Timer, 1.0-10Sec. 220V Dc, 2No+2Nc 240Vac Mtr Restart Control Timer (.2-60Secs) 240Vac On Delay Timer(1-10Secns)With 1No 220Vdc On Delay Timer(.5-5Secs) With 1No 220Vdc 0N Delay Timer(0.5-5Secs)With 3No 220Vdc On Delay Timer(1-10Secs) With 3No Meter Ac Ammeter (Digital) Ac Ammeter (Analog) Linear Scale Ac Ammeter (Analog) Compressed Scale Dc Ammeter (Digital) Dc Ammeter (Analog) Dc Ammeter With Shunt And Center Zero Ac Voltmeter (Digital) Dc Voltmeter (Analog) Wattmeter (3 Phase) Wattmeter (1 Phase) Tvm Meter Digital Energy Meter Frequency Meter Synchroscope Differential Voltmeter Differential Frequency Meter Multifunction Digital Energy Meter With Rs485 Port (0.2 Acc. Class) Multifunction Digital Energy Meter With Rs485 Port (0.5 Acc. Class) Multifunction Digital Energy Meter With Rs485 Port (1.0 Acc. Class) Single Phase Preventor Relay Mcb 6A, 4P 415V Ac 10A, 4P 415V Ac 16A, 4P 415V Ac 6A Dp, 240V Ac 10A Dp, 240V Ac 16A Dp, 240V Ac 32A Dp, 240V Ac 6A Dp, 110V Ac 10A Dp, 110V Ac 16A Dp, 110V Ac 32A Dp, 110V Ac 6A Dp, 220V Dc 10A Dp, 220V Dc 16A Dp, 220V Dc 6A Sp, 240V Ac 10A Sp, 240V Ac 16A Sp, 240V Ac 32A Sp, 240V Ac 6A Sp, 110V Ac 10A Sp, 110V Ac 16A Sp, 110V Ac 32A Sp, 110V Ac 6A Sp, 220V Dc 10A Sp, 220V Dc 16A Sp, 220V Dc Switch & Push Button Breaker Control Switch, 16A,220V Dc, 2Close+2Trip Dc Isolating Switch 16A,220V Dc, Dp, Base Mtg. 16A, 240V Ac Selector Switch 3Way, 4Pole, Flush Mtg 25A, 240V Ac Selector Switch 3Way, 4Pole, Flush Mtg 16A, 240V Ac Selector Switch 2Way, 2Pole, Flush Mtg Normal/ Trial Sel. Switch, 2Pole , 2Way, 10A 240V Ac, Flush Mtg, Mcc/ Normal/ Trial Sel. Switch, 2Pole ,3Way, 10A 240V Ac, Flush Mtg Swgr/ Remote Sel. Switch 3Pole 2Way,16A 220V Dc, Flush Mtg Swgr/ Normal/ Trial Sel. Switch, 3Pole, 3Way, 16A 220V Dc, Flush Mtg. Normal/ Trial Sel. Switch, 2Pole , 2Way, 10A 240V Ac, Flush Mtg, Lockabel Type Mcc/ Normal/ Trial Sel. Switch, 2Pole ,3Way, 10A 240V Ac, Flush Mtg, Lockabel Type Swgr/ Remote Sel. Switch 3Pole 2Way,16A 220V Dc, Flush Mtg.Lockable Type Swgr/ Normal/ Trial Sel. Switch, 3Pole, 3Way, 16A 220V Dc, Flush Mtg., Lockable Type Ammeter Selector Switch Voltmeter Selector Switch Toggle Switch 5A, 240V Ac Ac Switch Spst-5A,240V Ac 10A, 220V Dc Switch Door Limit Switch Ammeter Selector Switch Voltmeter Selector Switch Synchronisation Selector Switch Trip Selector Switch Push Button 2No + 2Nc Shrouded 1No + 1Nc Shrouded 2No + 2Nc Mushroom Head Stayput 2No + 2Nc Lockable Type Indicating Lamp Assembly (Led Type) 240V Ac-Green 240V Ac-Red 240V Ac- Amber 110V Ac-Green 110V Ac-Red 110V Ac- Amber 220V Dc-White 220V Dc-Red 220V Dc-Green 220V Dc-Blue 220V Dc- Amber 63.5V Ac-Red 63.5V Ac-Yellow 63.5V Ac-Blue Ct Metering Ct Upto 75/1A 100/1A 125/1A 150/1A 200/1A 250/1A 300/1A 400/1A 500/1A 630/1A 800/1A 1000/1A 1250/1A 1600/1A 2000/1A 2500/1A 3000/1A 4000/1A Protection Ct (5P20) Upto 75/1A 100/1A 125/1A 150/1A 200/1A 250/1A 300/1A 400/1A 500/1A 630/1A 800/1A 1000/1A 1250/1A 1600/1A 2000/1A 2500/1A 3000/1A 4000/1A 630/5A 800/5A 1000/5A 1250/5A 1600/5A 2000/5A 2500/5A 3000/5A 4000/5A Ps Class Ct 1000/1A 1600/1A 2000/1A 2500/1A 3000/1A 4000/1A 1000/5A 1600/5A 2000/5A 2500/5A 3000/5A 4000/5A Voltage Transformer 415/v3 : 110/v 3V, 50Va 415/v3 : 110/v3 V, 100Va 415/v3 : 240/v3 V, 50Va 415/v3 : 240/v3 V, 100Va 415 : 110V, 50Va 415 : 110V, 100Va 415 : 240V, 50Va 415 : 240V, 100Va Toggle Switch (16A) Secondary Isolating Contact Block Control Terminal (Fixed) Control Terminal (Drawout) Thermostat, Dial Type Control Transformer 415/240V,Cl-B, 1 Kva 415/240V,Cl-B, 2Kva 415/240V,Cl-B, 2.5Kva 415/240V,Cl-B, 3Kva 415/240V,Cl-B, 5Kva 415/240V,Cl-B, 7.5Kva 415/240V,Cl-B, 10Kva 415/110V,Cl-B, 1 Kva 415/110V,Cl-B, 2Kva 415/110V,Cl-B, 2.5Kva 415/110V,Cl-B, 3Kva 415/110V,Cl-B, 5Kva 415/110V,Cl-B, 7.5Kva 415/110V,Cl-B, 10Kva 415/110V,Cl-B, 10Kva 4-20Ma Dual O/P, Aux Sup 220V Dc, 1A, Current Transducer 4-20Ma Dual O/P, Aux Sup 240V Ac, 1A, Current Transducer 4-20Ma Dual O/P, Aux Sup 110V Ac, 1A, Current Transducer 4-20Ma Dual O/P, Aux Sup 220V Dc, Voltagetransducer, Ptr 415/110V 4-20Ma Dual O/P, Aux Sup 240V Ac, Voltagetransducer, Ptr 415/110V 4-20Ma Dual O/P, Aux Sup 110V Ac, Voltagetransducer, Ptr 415/110V 4-20Ma Dual O/P, Aux Sup 220V Dc, Frequencytransducer, Ptr 415/110V 4-20Ma Dual O/P, Aux Sup 220V Dc, Input 0-75Mv Dc, Current Transducer-Dc 4-20Ma Dual O/P, Aux Sup 240V Ac, Input Voltage 0-220V Dc, Voltage Transducer-Dc 4-20Ma Dual Output Kw Transducer 4-20Ma Dual Output Kva Transducer 4-20Ma Dual Output providing fixing Transducer 4-20Ma Dual Output Frequency Transducer Interposing Relay Re 302 Or Eqvt With Freewheeling Diode & Led 3 Pin Socket - 5A, 110V Ac, 3Pin Space Heater Neutral Link With Mounting Assembly 20A For Control Ckt. & Power Ckt. Upto 25A Mccb Rating 32A For 50A Mccb Rating 63A For 100A & 125A Mccb Rating 125A For 250A Mccb Rating 250A For 400A & 500A Mccb Rating Castle Key Interlock For Mccb - 3Lock+2Key Mechanical Interlock For Power Contactor 16A 25A 32A 63A 80A 115A 150A 185A 265A 315A 400A Addon Block For Contactor 2No+2Nc 3No+1Nc 1No + 1Nc 1No 1Nc Isolating Transformer Isolating Transformer-15Kva Isolating Transformer-20Kva Isolating Transformer-25Kva Isolating Transformer-30Kva Isolator With Handle 16A 32A , Foundation Frame Mcc Panel Upto 1600A (Sf) 2500A (Sf) 3000A (Sf) 4000A (Sf) Upto 1600A (Df) 2500A (Df) 3000A (Df) 4000A (Df) 220V Dcdb Panel Sf Df Plain Cement Concrete / Pmcc Panel Upto 1600A 2000A 2500A 3000A 4000A , Connection From Pmcc/Mcc Panel To Pmcc/Mcc Panel 250A 400A 630A 800A 1000A 1200A 1600A 2000A 2500A 3000A 4000A , Cable Glands & Lugs: Single Compression Cable Glands For Cable Sizes: 2C X 2.5 Sq. Mm. 3C X 2.5 Sq. Mm. 5C X 2.5 Sq. Mm. 7C X 2.5 Sq. Mm. 10C X 2.5 Sq. Mm. 14C X 2.5 Sq. Mm. 2C X 10 Sq. Mm. 2C X 16 Sq. Mm. 2C X 25 Sq. Mm. 2C X 35 Sq. Mm. 2C X 50 Sq. Mm. 2C X 70 Sq. Mm. 2C X 95 Sq. Mm. 3C X 2.5 Sq. Mm. 3C X 10 Sq. Mm. 3C X 16 Sq. Mm. 3C X 25 Sq. Mm. 3C X 35 Sq. Mm. 3C X 50 Sq. Mm. 3C X 70 Sq. Mm. 3C X 95 Sq. Mm. 3C X 150 Sq. Mm. 3C X 240 Sq. Mm. 3C X 300 Sq. Mm. 3.5C X 25 Sq. Mm. 3.5C X 50 Sq. Mm. 3.5C X 70 Sq. Mm. 3.5C X 95 Sq. Mm. 3.5C X 240 Sq. Mm. 3.5C X 300 Sq. Mm. 4C X 16 Sq. Mm. 4C X 35 Sq. Mm. 1C X 300 Sq. Mm. 1C X 630 Sq. Mm. Double Compression Cable Glands For Cable Sizes: 2C X 2.5 Sq. Mm. 3C X 2.5 Sq. Mm. 5C X 2.5 Sq. Mm. 7C X 2.5 Sq. Mm. 12C X 2.5 Sq. Mm. 16C X 2.5 Sq. Mm. 2C X 10 Sq. Mm. 2C X 16 Sq. Mm. 2C X 25 Sq. Mm. 2C X 35 Sq. Mm. 2C X 50 Sq. Mm. 2C X 70 Sq. Mm. 2C X 95 Sq. Mm. 3C X 2.5 Sq. Mm. 3C X 10 Sq. Mm. 3C X 16 Sq. Mm. 3C X 25 Sq. Mm. 3C X 35 Sq. Mm. 3C X 50 Sq. Mm. 3C X 70 Sq. Mm. 3C X 95 Sq. Mm. 3C X 150 Sq. Mm. 3C X 240 Sq. Mm. 3C X 300 Sq. Mm. 3.5C X 25 Sq. Mm. 3.5C X 50 Sq. Mm. 3.5C X 70 Sq. Mm. 3.5C X 95 Sq. Mm. 3.5C X 240 Sq. Mm. 3.5C X 300 Sq. Mm. 4C X 16 Sq. Mm. 4C X 35 Sq. Mm. 1C X 300 Sq. Mm. 1C X 630 Sq. Mm. Cable Lugs For Sizes: 1.5 Sq. Mm. 2.5 Sq. Mm. 10 Sq. Mm. 16 Sq. Mm. 25 Sq. Mm. 35 Sq. Mm. 50 Sq. Mm. 70 Sq. Mm. 95 Sq. Mm. 120 Sq. Mm. 150 Sq. Mm. 185 Sq. Mm. 240 Sq. Mm. 300 Sq. Mm. 630 Sq. Mm. , Thermal O/L Relay With Spp - Olr Upto 5.5Kw 5.6 To 7.0Kw 7.1 To 13Kw 13.1 To 24Kw 24.1 To 29.9Kw 30.0 To 37.0Kw 37.1 To 55.0Kw 55.1 To 80.0Kw 80.1 To 89.9Kw , Heavy Duty Thermal O/L Relay With Spp - Olr Upto 5.5Kw 5.6 To 7.0Kw 7.1 To 13Kw 13.1 To 24Kw 24.1 To 29.9Kw 30.0 To 37.0Kw 37.1 To 55.0Kw 55.1 To 80.0Kw 80.1 To 89.9Kw , Daily 8 Hour Rate Deployed At Site: Engineer : (Per Day) , Module Name Plate , Wires For Secondary Wiring: 1.5 Sq. Mm. Per Meter 2.5 Sq. Mm. Per Meter 4.0 Sq. Mm. Per Meter , Control Terminal For Secondary Wiring Suitable For Cable Size: 0.5 Sq. Mm. 1.5 Sq. Mm. 2.5 Sq. Mm. , Electrical Junction Boxes (For Termination Of 0.5 Sqmm Screened Control Cables) 48 Ways 64 Ways 72 Ways 96 Ways , Ismc Channels Ismc 75 Channel Per Meter Ismc 100 Channel Per Meter , Temperature Sensor For Wireless Temperature Monitoring Sensor , Wireless Transmitter For Wireless Temperature Monitoring Sensor , Wireless Receiver For Wireless Temperature Monitoring Sensor , Additional Components (Except Networking Hardware Mentioned In Annexure B3) Required For Completeness Of Wireless Temperature Monitoring Sensor , Dp Mccb, Adj. Sc & O/L Release: 16A 25A 32A 63A 100A 125A 160A 200A , Tp Mccb Motor Duty Type With S/C Release: 16A 25A 32A 63A 100A 125A 160A 200A 250A 400A , Tp Mccb Adj S/C , O/L, E/F Release: 16A 25A 32A 63A 80A 100A 125A 160A 200A 250A 400A , Dc Mccb 16A 25A 32A 63A 80A 115A 150A 185A 265A 315A 400A , Switch Fuse Unit (Dc) - Dp Along With Fuse, Link Etc Complete (Suitable For 40Ka Fault Current) 16A 32A 63A 100A 125A 200A 250A 300A 400A 600A 800A , Switch Fuse Unit (Ac) - Tp Along With Fuse, Link Etc Complete 16A 32A 63A 100A 125A 200A 250A 300A 400A 600A 800A , Olm, Profibus Dp Connector Along With Accessories (At Y-Link End) For Interface Of Y-Link With Ddcmis. , Sp On/ Off Switch For Motor Space Heater Of Breaker Motor Fdr, 10A, 240V Ac , 4 Pole, 2 Posi., Selector Switch For Control Trf., 110V Ac , Extended Rotory Handle , Auxiliary Contact For Mccb 1C/O , Trip Contact For Mccb 1C/O , Control Terminals (Drawout) , 3 Pin Industrial Socket & Plug , Rotary On/Off Switch , Timer With 2C/O , Control Transformer, Dry Type, Cast Resin, 415/24V, Ins. Cl-B Or Better , Rectifier , Limit Switch (Breaker) , Ethernet Switch With 16 Copper Ports & 4 Fo Ports , Ethernet Switch With 08 Copper Ports & 4 Fo Ports , Cat5e/ Cat6 Ethernet Cable , Fibre Optic Patch Cord (Minimum Length - 10Metres) , 9 Windows Alarm Annunciation -1 , Electronic Hooter (96Sqmm) , Class 0.2S Accuracy Energy Meters Suitable For Abt Requirement (Specification In Annexure-I) The Bidder Should List The Unit Price For Any Additional Modules, Components, Or Items That Are Not Mentioned In The Above Specifications But May Be Necessary To Fulfill The Customers Requirements. Annexure - Ii Schedule Of Technical And Commercial Deviation Project:- 2X800 Mw Ntpc Singrauli Stpp Stage - Iii Package:-Lt Switchgear Tender Ref No - , Dated 02-05-2026 Name Of Vendor:- Sl No Voulme/ Section Page No. Clause No. Technical Specification/ Tender Document Complete Description Of Deviation Cost Of Withdrawl Of Deviation Reference Of Price Schedule On Which Cost Of Withdrawl Of Deviation Is Applicable Nature Of Cost Of Withdrawl Of Deviation (Positive/ Negative) Reason For Quoting Deviation Technical Deviations Commercial Deviations Particulars Of Bidders/ Authorised Representative Name Designations Sign & Date Notes: 1. Cost Of Withdrawl Of Deviation Will Be Applicable On The Basic Price (I.E. Excluding Taxes, Duties & Freight) Only. 2. All The Bidders Have To List Out All Their Technical & Commercial Deviations (If Any) In Detail In The Above Format. 3. Any Deviation Not Mentioned Above And Shown Separately Or Found Hidden In Offer, Will Not Be Taken Cognizance Of. 4. Bidder Shall Submit Duly Filled Unpriced Copy Of Above Format Indicating Quoted In Cost Of Withdrawl Of Deviation Column Of The Schedule Above Along With Their Techno-Commercial Offer, Wherever Applicable. In The Absence Of Same, Such Deviation(S) Shall Not Be Considered And Offer Shall Be Considered In Total Compliance To Nit. 5. Bidder Shall Furnish Price Copy Of Above Format Along With Price Bid. 6. The Final Decision Of Acceptance/ Rejection Of The Deviations Quoted By The Bidder Shall Be At Discretion Of The Purchaser. 7. Bidders To Note That Any Deviation (Technical/Commercial) Not Listed In Above And Asked After Part-I Opening Shall Not Be Considered. 8. For Deviations W.R.T. Credit Period, Liquidated Damages, Firm Prices If A Bidder Chooses Not To Give Any Cost Of Withdrawl Of Deviation Loading As Per Annexure-Vii, Will Apply. For Any Other Deviation Mentioned In Un-Priced Copy Of This Format Submitted With Part-I Bid But Not Mentioned In Priced Copy Of This Format Submitted With Priced Bid, The Cost Of Withdrawl Of Deviation Shall Be Taken As Nil. 9. Any Deviation Mentioned In Priced Copy Of This Format, But Not Mentioned In The Un-Priced Copy, Shall Not Be Considered. 10. All Techno-Commercial Terms And Conditions Of Nit Shall Be Deemed To Have Been Accepted By The Bidder, Other Than Those Listed In Unpriced Copy Of This Format. 11. Cost Of Withdrawl Is To Be Given Seperately For Each Deviation. In No Event Bidder Should Club Cost Of Withdrawl Of More Than One Deviation Else Cost Of Withdrawl Of Such Deviations Which Have Been Clubbed Together Shall Be Considered As Nil. 12. In Case Nature Of Cost Of Withdrawl (Positive/Negative) Is Not Specified It Shall Be Assumed As Positive. 13. In Case Of Descrepancy In The Nature Of Impact (Positive/ Negative), Positive Will Be Considered For Evaluation And Negative For Ordering. , 2X800 Mw Ntpc Singrauli Stpp Stage - Iii Boq-Cum-Price Schedule For Lt Switchgear Nit No. , Dated 02.052026 Bidder Name:- S.No. Item No. Item Name Uom Total Qty. Rating (A) Board No. Unit Price (Ex-Works) Rs. Total Price (Ex-Works) Rs. Freight % In W.R.T Total Ex- Works (In %) Freight Amount (Rs.) Total Price (Exworks + Freight) (Rs.) Gst@18% On Ex-Works + Freight (Rs.) Total For Site Price (Rs.) No. Of Plain Cement Concrete / Acb Panel No. Of Mcc / Acdb / Dcdb Panel Board Name Plate, Description & Rating , 506-0110316-00-A , 506-0110040-00-A , 506-0110382-00-A , 506-0110107-00-A , 506-0110092-00-A , 506-0110419-00-A , 506-0110387-00-A , 506-0110321-00-A , 506-0110300-00-A , 506-0110317-00-A , 506-0110041-00-A , 506-0110383-00-A , 506-0110108-00-A , 506-0110093-00-A , 506-0110420-00-A , 506-0110388-00-A , 506-0110322-00-A , 506-0110301-00-A , 506-0110179-00-A , 506-0110180-00-A , 506-0110181-00-A , 506-0110182-00-A , 506-0110183-00-A , 506-0110170-00-A , 506-0110165-00-A , 506-0110171-00-A , 506-0110166-00-A , 506-0110264-00-A , 506-0110077-00-A , 506-0110331-00-A , 506-0110241-00-A , 506-0110079-00-A , 506-0110983-00-A , 506-0110265-00-A , 506-0110332-00-A , 506-0110242-00-A , 506-0110080-00-A , 506-0110984-00-A , 506-0110162-00-A , 506-0110142-00-A , 506-0110259-00-A , 506-0110339-00-A , 506-0110184-00-A , 506-0110254-00-A , 506-0111020-00-A , 506-0111019-00-A , 506-0111032-00-A , 506-0110251-00-A , 506-0110044-00-A , 506-0111033-00-A , 506-0111035-00-A , 506-0110190-00-A , 506-0111024-00-A , 506-0111025-00-A , 506-0111026-00-A , 506-0111021-00-A , 506-0111022-00-A , 506-0111034-00-A , 506-0110977-00-A , 506-0110404-00-A , 506-0110411-00-A , 506-0111030-00-A , 506-0111031-00-A , 506-0110412-00-A , 506-0110985-00-A , 506-0110986-00-A , 506-0110417-00-A , 506-0111006-00-A , 506-0110991-00-A , 506-0111007-00-C , 506-0110282-00-A , 506-0110991-00-A , 506-0110989-00-A , 506-0110000-00-B , Grand Total (Evaluation Price Shall Be Exworks + Freight) Notes: , To Calculate The Switchboard Prices, Refer Detailed Board Wise Bom And Module Wise Bom, Annexure-A.1 And Annexure-A.2 Of Technical Data Part-A Of Technical Specification (Pe-Ts-512-506-E002) Respectively. , Bidder Has To Quote For The Following Along With The Bid: I) Hmi System: As Per List In Annexure-A Ii) Networking Hardware For Numerical Relays, Imc As Per List In Annexure-B1 & For Wireless Temperature Monitoring System As Per List In Annexure-B3 Iii) annual maintenance contract For Numerical Relays As Per Annexure-B2 Iv) Numerical Relay, Imcc, Wireless Temperature Monitoring & Hmi System Commissioning: As Per Annexure-C V) Tools & Tackles: As Per Annexure-D Vi) Site Modification Charges: As Per Annexure-E Vii) E & C Spares: As Per Annexure-F Viii) Mandatory Spare: As Per List In Annexure-G Ix) Bidder To Provide A Schedule Of Unit Prices In Accordance With The List Provided In Annexure-H , Bidder To Ensure That Summation Of Prices (As Per Annexure-H) Of Applicable Modules (As Per Annexure A.1-Boardwise Bom) And Applicable Panels (Mentioned Above By The Bidder) Of A Board Shall Be Equivalent To Board Price Quoted Above For That Board. Variation Of +/- 5% Is Acceptable In The Derived Price From The Board Price Quoted Above. , Addition/ Deletion Of Quantities Shall Be Applicalbe At The Quoted Prices. Allowable Variation In Quantity And Price Shall Be As Per Nit. , All Lt Pcc/ Pmcc/Mcc/ Dbs Shall Be Supplied Alongwith The Integral Base Frames, Foundation Bolts, Cable Glands & Lugs. Prices For The Same Shall Be Built In The Switchboard Price. , Bidder Is Required To Provide The Quantity Of Panels Corresponding To Each Board In The Table Above When Submitting Their Techno-Commercial Proposal. , In Case Module Doors Are Part Of Modules, 2 Nos Of Dummy Modules Of Each Size To Fill In Module Being Taken Out For Maintenance Purpose Shall Be Provided In Each Switchgear Room (Refer Annexure-3_Tentative Switchgear Location Of Technical Specification Pe-Ts-512-506-E002), These Dummy Modules Shall Be Fitted In Switchboard As Vacant Modules Having No Cut Out On Back Side And Cable Alley Side. In Case Door Is Hinged To The Panel, 2 Nos Of Blanking Plates Of Each Size Need To Be Provided. Prices For The Same Shall Be Built In The Switchboard Price. , No Additional Prices Shall Be Paid For Prototype Panels, Prices Quoted Above Includes Cost Of Prototype Panels Also. , Pvc Shall Be Applicable For This Enquiry For Pmcc / Plain Cement Concrete / Mcc / Acbd / Dcdb Only) As Per Ieema Circular (Https://Ieema.Org/Wp-Content/Uploads/2020/07/Lvswgr-Jan-2019.Pdf) .Price Variation Is Not Applicable For Ac Mccb Box; Dc Mccb Box; Hmi System; Numerical Relay, Imcc And Wireless Temp Monitoring System- Networking Hardware; annual maintenance contract For Numerical Relay; Numerical Relay, Imcc, Wireless Temp Monitoring And Hmi System- Commissioning; Tools & Tackle; Site Modification; E & C Spares & Mandatory Spares. , In Unit Addition-Deletion Prices (Annexure-H), Prices Quoted For Components Shall Be Reasonable And As Per List Price Of Concerned Manufacturers. Annexure-A Hmi System S. No. Item Description Qty. Unit Unit Price (Ex-Works) Rs. Total Price (Ex-Works) Rs. Freight % In W.R.T Total Ex- Works (In %) Freight Amount (Rs.) Total Price (Exworks + Freight) (Rs.) Gst@18% On Ex-Works + Freight (Rs.) Total For Site Price (Rs.) Remarks Complete Design, Engineering & Supply Of The Following Items : , Hmi (Ews) , Console For Hmi , Laser Printer (A4 Size) , Table For Printer , Total Of Annexure A Note: , Refer Annexure-1_Typical Switchgear Relay Network Architecture. , Industrial Modular Design Console (Furniture I.E. Table With Drawer & Swivel Computer Chair) Shall Be Provided. Each Console Shall Have Space For Keeping An Additional Pc. , Make And Color Shade Of Furniture Shall Be Decided During Detail Engineering. Furniture Color Shade Should Match With Control Room Furniture. , Bhel Will Provide Ups Redundant Feeder At One Location Near To Ews Location. Further Distribution Of Ups Supply (For Hmi, Network Switch Etc.) Along With Ups Db Shall Be In The Scope Of Bidder. , For Testing And Erection & Commissioning Charges For Hmi- Items, Kindly Refer S.No.4 Of Annexure-C. . Annexure-B1 Networking Hardware For Numerical Relay & Imcc S. No. Item Description Qty. Unit Unit Price (Ex-Works) Rs. Total Price (Ex-Works) Rs. Freight % In W.R.T Total Ex- Works (In %) Freight Amount (Rs.) Total Price (Exworks + Freight) (Rs.) Gst@18% On Ex-Works + Freight (Rs.) Total For Site Price (Rs.) Remarks , Ethernet Switch With Iec-61850 Protocol , Network Level Ethernet Switch (Of Adequate Ports) , Cat5e/Cat6 Or Better Ethernet Cable , Simplex Fiber Optical Cable For Communication Between Swgr Level Ethernet Switchs (& Their Rings) & Network Level Ethernet Switch , Hdpe Conduit (Rodent Free) , Fo Termination Accessories At Bidders Supplied Equipment End Under This Package , Laptop Pc With Licenced Version Software, Hardware For Relay, Imc Parameterisation , Interface Cable With Suitable Connecting Port At Both End For Connection Of Numerical Relay Front Port To The Laptop , Interface Cable With Suitable Connecting Port At Both End For Connection Of Imcc Front Port To The Laptop , Total Of Annexure B1 Notes: , Refer Annexure- 3_Tentative Switchboard Location Detail For Distance Between Switchgear And Network Level Ethernet Switch In Main Control Room. , Refer Annexure- 1_Typical Switchgear Relay Network Architecture For Hmi Requirement. , Bidder To Provide One No. Of Each Type Of Imcc Module Along With Y-Link To Bhel On Returnable Basis & Coordinate With Bhel For Conducting Fat For Imcc As Per Customer Satisfaction. Annexure-B2 annual maintenance contract For Numerical Relay S. No. Item Description Qty. Unit Unit Price (Ex-Works) Rs. Total Price (Ex-Works) Rs. Gst@18% On Ex-Works (Rs.) Total For Site Price (Rs.) Remarks , annual maintenance contract For 3 Years For Following : - Numerical Relays (With Iec 61850) In All Lv Switchgears - Iec 61850 Ethernet Switches In Switchgear Panels - Cat5e Ethernet Cable / Fo Cable/ Optical Fibre Cable With Fire Retardant Outer Sheath - Optical Fibre Cable Termination Equipment Such As Liu, Patch Cord Etc. For Complete Network - Laptops - Hmi Stations (Engineering Work Stations And Printers) - All Other Equipment Required To Meet The Intended Specification , 1St Year , 2Nd Year , 3Rd Year , Total Of Annexure B2 Notes: , The Commencement Date For annual maintenance contract Will Be From The Date Of Takeover By The End Customer. However, Tentative Date Of annual maintenance contract Commencement Shall Be 05.05.2028. Annexure-B3 Networking Hardware For Wireless Temperature Monitoring Sensor S. No. Item Description Qty. Unit Unit Price (Ex-Works) Rs. Total Price (Ex-Works) Rs. Freight % In W.R.T Total Ex- Works (In %) Freight Amount (Rs.) Total Price (Exworks + Freight) (Rs.) Gst@18% On Ex-Works + Freight (Rs.) Total For Site Price (Rs.) Remarks 1.A Complete Networking Hardware(Except Cable & Termination Accessories) Near Switchgear End For Communication Between Wireless Temperature Receiver End & Ddcmis/Hmi For Temperature Monitoring System :- For Two Set Of Switchboards- A. First Set- 8Da, 8Db & 8Dg B. Second Set- 9Da, 9Db & 9Dg 2.0 Set 0.0 0.0 0.0 0.0 0.0 Including Complete Design, Engineering And Supply. 1 Set Is For Each Unit (Consists Of 3 Switchboards) 1.B Special Cable(Twisted Pair/Cat/Optical Fibre Cable Or As Applicable) Including Termination Accessories For Communication Between Switchgear & Ddcmis/Hmi For Temperature Monitoring System :- For Two Set Of Switchboards- A. First Set- 8Da, 8Db & 8Dg B. Second Set- 9Da, 9Db & 9Dg 2.0 Set 0.0 0.0 0.0 0.0 0.0 Including Complete Design, Engineering And Supply. 1 Set Is For Each Unit (Consists Of 3 Switchboards) 2.A Complete Networking Hardware(Except Cable & Termination Accessories) Near Switchgear End For Communication Between Wireless Temperature Receiver End & Ddcmis/Hmi For Temperature Monitoring System :- For Two Set Of Switchboards- A. First Set- 0Da B. Second Set- 0Db 2.0 Set 0.0 0.0 0.0 0.0 0.0 Including Complete Design, Engineering And Supply. 1 Set Is For Each Unit (Consists Of 1 Switchboard) 2.B Special Cable(Twisted Pair/Cat/Optical Fibre Cable Or As Applicable) Including Termination Accessories For Communication Between Switchgear & Ddcmis/Hmi For Temperature Monitoring System :- For Two Set Of Switchboards- A. First Set- 0Da B. Second Set- 0Db 2.0 Set 0.0 0.0 0.0 0.0 0.0 Including Complete Design, Engineering And Supply. 1 Set Is For Each Unit (Consists Of 1 Switchboard) Total Of Annexure B3 0.0 0.0 0.0 0.0 0.0 Notes: , Refer Annexure- 3_Tentative Switchboard Loaction Detail For Distance Between Switchgear And Main Control Room. , For Above Items Listed At S.No.1.A And 1.B, Bmcc(8Da), Tmcc (8Db) And Emcc(8Dg) Of One Unit Is Considered As 1 Set Annexure-C Numerical Relay, Imcc, Wireless Temperature Monitoring & Hmi Systems - Commissioning Charges S. No. Item Description Qty. Unit Unit Price (Ex-Works) Rs. Total Price (Ex-Works) Rs. Gst@18% On Ex-Works (Rs.) Total For Site Price (Rs.) Remarks , Lump Sum All Inclusive Charges Per Numerical Relay Commissioning (Including Conveyance To Site, Boarding And Lodging) , Lump Sum All Inclusive Charges Per Imc Commissioning (Including Conveyance To Site, Boarding And Lodging) 3.A Lump Sum All Inclusive Charges For Wireless Temperature Monitoring System Commissioning. For Two Lot Of Switchboards- A. First Lot- 8Da, 8Db & 8Dg Switchboards B. Second Lot- 9Da, 9Db & 9Dg Switchboards 2.0 Lot 0.0 0.0 0.0 1 Lot Is For Each Unit (Consists Of 3 Switchboard). Refer Note No.3A & 4A 3.B Lump Sum All Inclusive Charges For Wireless Temperature Monitoring System Commissioning. For Two Lot Of Switchboards- A. First Lot- 0Da Switchboard B. Second Lot- 0Db Switchboard 2.0 Lot 0.0 0.0 0.0 1 Lot Is For Each Unit (Consists Of 1 Switchboard). Refer Note No.3B & 4B , Testing And Erection & Commissioning Charges For Hmi- Items At Sl. No. 1-4 Of Annexure-A , Total Of Annexure C Notes: , Amount Payable For Numerical Relay Commissioning = Unit Price For Commissioning Charges As Per Sl.No.1 Above X No. Of Relays Commissioned (Same To Be Certified By Bhel). , Amount Payable For Imcc Commissioning = Unit Price For Commissioning Charges As Per Sl.No.2 Above X No. Of Imcc Commissioned (Same To Be Certified By Bhel). 3.A Amount Payable For Wireless Temperature Monitoring System Commissioning For Each Unit (Bmcc, Tmcc And Emcc) = Unit Price For Commissioning Charges As Per Sl.No.3.A Above (Same To Be Certified By Bhel). 3.B Amount Payable For Wireless Temperature Monitoring System Commissioning For Each Unit (Station Service Switchboard) = Unit Price For Commissioning Charges As Per Sl.No.3.B Above (Same To Be Certified By Bhel). 4.A For Line Item 3.A, Testing And Commissioning Of Wireless Temperature Monitoring System For Bmcc(8Da), Tmcc (8Db) And Emcc(8Dg) Of One Unit Is Considered As 1 Lot, Similarly 3 Boards Of Another Unit For 2Nd Lot. 4.B For Line Item 3.B, Testing And Commissioning Of Wireless Temperature Monitoring System For Station Service Switchboard (0Da) Of One Unit Is Considered As 1 Lot, Similarly 1 Board Of Another Unit For 2Nd Lot. , Approximately 15 Nos. Of Numerical Relays And/Or 50 Nos. Of Imcs Can Be Considered By Bidder For Commissioning In Each Visit. , For Line Item 1, 2, 3.A & 3.B, Bidder To Note That Testing, Configuration And Networking Setup Of Relay, Imc & Temperature Monitoring System Shall Be The BidderS Responsibility Completely. , For Line Item 4, Bidder To Note That Erection & Commissioning, Testing, Configuration And Networking Setup Of Hmi System Shall Be The BidderS Responsibility Completely. , Bidder To Coordinate With Dcs Suppplier (Bhel Edn) To Ensure Smooth And Effective Communication Between Numerical Relay/ Y-Link And Dcs, As Well As Between Temperature Monitoring System And Dcs/Hmi. , For Line Items 1 To 4, Bidder To Depute Its Manpower Within 15 Days From The Date Of Intimation By Bhel. Annexure-D Tools & Tackles S. No. Item Description Quantity Unit Unit Price (Ex-Works) Rs. Total Price (Ex-Works) Rs. Freight % In W.R.T Total Ex- Works (In %) Freight Amount (Rs.) Total Price (Exworks + Freight) (Rs.) Gst@18% On Ex-Works + Freight (Rs.) Total For Site Price (Rs.) Remarks , Acb Racking Handle , Telescopic Trolly (Trolley For Acb Handling) , Door Key , Relay Test Equipment , Module Racking Handle , Total Of Anenxure -D Notes: , Bidder Has To Quote For Tools And Tackles Mentioned Above. However, Bidder Has To Indicate Any Special Tools (If Required). Annexure-E Site Modification Charges S. No. Item Description Quantity Unit Unit Price (Ex-Works) Rs. Total Price (Ex-Works) Rs. Gst@18% On Ex-Works (Rs.) Total For Site Price (Rs.) , Lump Sum All Inclusive Charges Per Visit For Skilled Technician (Except Daily Charges) , Lump Sum All Inclusive Daily Charges For Skilled Technician , Lump Sum All Inclusive Charges Per Visit For Service Engineer (Except Daily Charges) , Lump Sum All Inclusive Daily Charges For Service Engineer , Site Modification Material @ 1% Of Total Board Cost (I.E. Summation Of S.No. 1 To S.No. 64 Of Boq Cum Price Schedule) , Total Of Annexure E Notes: , Amount Payable For Skilled Technician Per Visit To Site = Visit Charges As Per Sl. No. 1 Above + (Daily Charges As Per Sl. No. 2 Above X No. Of Days At Site) (To Be Certified By Bhel Site) , Amount Payable For Service Engineer Per Visit To Site = Visit Charges As Per Sl. No. 3 Above + (Daily Charges As Per Sl. No. 4 Above X No. Of Days At Site) (To Be Certified By Bhel Site) , Amount Payable For Site Modification Material Shall Be Based On The Actual Cost Of The Materials Utilized. (To Be Certified By Bhel Site). The Cost Of The Actual Materials Used Will Be Determined Using The Unit Rate Provided By The Bidder In The Annexure-H. , For Line Items 1 To 4, Bidder To Depute Its Manpower Within 15 Days From The Date Of Intimation By Bhel. Annexure-F E&C Spares S. No. Item / Component Qty. Unit Unit Price (Ex-Works) Rs. Total Price (Ex-Works) Rs. Freight % In W.R.T Total Ex- Works (In %) Freight Amount (Rs.) Total Price (Exworks + Freight) (Rs.) Gst@18% On Ex-Works + Freight (Rs.) Total For Site Price (Rs.) , Factory Built Assemblies (Pcc/Mcc/Db) , Busbar Supports (Horizontal) , Primary Isolating Contacts (Bus Side) Of Each Rating , Primary Isolating Contacts (Load Side) Of Each Rating , Secondary Isolating Contacts Of Each Rating , Gaskets (Each Size) , Fixed Terminal (1Way) , Shrouds (For Outgoing Modules) - One For Each Physical Size Of Module 1.8.A. Wire (For Secondary Wiring)-2.5 Mm2 100.0 Metres 0.0 0.0 0.0 0.0 0.0 1.8.B. Wire (For Secondary Wiring)-1.5Mm2 100.0 Metres 0.0 0.0 0.0 0.0 0.0 , Lugs (For Secondary Wiring) , Air Circuit Breaker (For Each Rating) , Shunt Trip Coil , Spring Charging Motor-1 Motor Of Each Rating , Closing Coil , Auxiliary Switch , Isolating Switch , Main Contact Kit For Each Rating , Power Contactors , Contactor Coil Of Each Rating , Contacts Kit (Main) For Each Rating , Auxiliary Contactors , Complete Unit With 2No + 2Nc Contacts-1 No. Of Each Rating/Type 5.2.A. Contactor Coils-Ac For Each Rating 1.0 Set 0.0 0.0 0.0 0.0 0.0 5.2.B. Contactor Coils-Dc For Each Rating 1.0 Set 0.0 0.0 0.0 0.0 0.0 , Mccb-1 No. Of Each Rating/Type , Mpcb -1 No. Of Each Rating/Type , Mcb-1 No. Of Each Rating/Type , Push Buttons , Actuator Contacts , Element , Indicating Lamps , Complete Unit , Lens (Assorted) , Others , Selector & Control Switch (Each Type) , Connecting Cable Between Ct And Imcc Of Appropriate Length , Connecting Cable Between Vt And Imcc Of Appropriate Length , Imc Display Hmi Cable Of Appropriate Length , Total Of Annexure -F , Complete Breaker Of Each Rating , Numerical Relays Of Each Type , Auxiliary Relays Of Each Type , Horizontal Busbar Support Insulators , Vertical Busbar Dropper Support Insulators , Current Transformer Of Each Type & Ratio , Voltage Transformer Of Each Type & Ratio , Control Supply Transformer Of Each Type & Rating , Power Contactor Of Each Type And Rating , Coil For Above Contactor For Each Type And Rating , Mccbs (Equally Divided For All Ratings) , Mpcbs (Equally Divided For All Ratings) , Closing Coil Of Each Type Of Each Rating , Trip Coil Of Each Type Of Each Rating , Aux Contact Set Of Each Type And Rating , Fixed Contact Set Of Each Type & Rating , Moving Contact Set Of Each Type & Rating , Maintenance Tools And Accessories For Maintenance Of Lt Mcc , Total Of Annexure -G , Incoming Feeder Unit Acb Incomer To Pcc/Pmcc From Trafo. - Module Type Daet (I/C) 1000A 1600A 2000A 2500A 3000A 4000A Acb Incomer To Mcc - Module Type Dae (I/C) 630A 800A 1000A 1250A 1600A 2000A 2500A 3000A 4000A Acb Incomer To Emergency Board - Module Type Dg(I/C) 800A 1000A 1250A 1600A 2000A 2500A 3000A 4000A Mccb Incomer For Mcc / Acdb - Module Type E3 (I/C) 63A - Fixed Type 125A - Fixed Type 160A - Fixed Type 200A - Fixed Type 250A - Fixed Type 300A - Fixed Type 400A - Fixed Type 63A - Drawout Type 125A - Drawout Type 160A - Drawout Type 200A - Drawout Type 250A - Drawout Type 300A - Drawout Type 400A - Drawout Type Mccb Incomer With Contactor Changeover - Module Type cement concrete 16A - Fixed Type 32A - Fixed Type 63A - Fixed Type 125A - Fixed Type 200A - Fixed Type 250A - Fixed Type 300A - Fixed Type 400A - Fixed Type 16A - Drawout Type 32A - Drawout Type 63A - Drawout Type 125A - Drawout Type 200A - Drawout Type 250A - Drawout Type 300A - Drawout Type 400A - Drawout Type 220V Dcdb Incomer From Charger - Module Type Ch (I/C) 50A - Ch Fixed Type 100A - Ch Fixed Type 125A - Ch Fixed Type 150A - Ch Fixed Type 200A - Ch Fixed Type 300A - Ch Fixed Type 400A - Ch Fixed Type 450A - Ch Fixed Type 500A - Ch Fixed Type 630A - Ch Fixed Type 800A - Ch Fixed Type 1000A - Ch Fixed Type 1250A - Ch Fixed Type 1600A - Ch Fixed Type 50A - Ch Drawout Type 100A - Ch Drawout Type 125A - Ch Drawout Type 150A - Ch Drawout Type 200A - Ch Drawout Type 300A - Ch Drawout Type 400A - Ch Drawout Type 450A - Ch Drawout Type 500A - Ch Drawout Type 630A - Ch Drawout Type 800A - Ch Drawout Type 1000A - Ch Drawout Type 1250A - Ch Drawout Type 1600A - Ch Drawout Type 220V Dcdb Incomer From Battery - Module Type Db (I/C) 50A - Db Fixed Type 100A - Db Fixed Type 125A - Db Fixed Type 150A - Db Fixed Type 200A - Db Fixed Type 300A - Db Fixed Type 400A - Db Fixed Type 450A - Db Fixed Type 500A - Db Fixed Type 630A - Db Fixed Type 800A - Db Fixed Type 1000A - Db Fixed Type 1250A - Db Fixed Type 1600A - Db Fixed Type 50A - Db Drawout Type 100A - Db Drawout Type 125A - Db Drawout Type 150A - Db Drawout Type 200A - Db Drawout Type 300A - Db Drawout Type 400A - Db Drawout Type 450A - Db Drawout Type 500A - Db Drawout Type 630A - Db Drawout Type 800A - Db Drawout Type 1000A - Db Drawout Type 1250A - Db Drawout Type 1600A - Db Drawout Type , Buscoupler Unit Acb Buscoupler To Pcc/Pmcc/Mcc - Module Type Daet/ Dae (B/C) 630A 800A 1000A 1250A 1600A 2000A 2500A 3000A 4000A Mccb Buscoupler For Mcc / Acdb - Module Type E3 (B/C) 63A - Fixed Type 125A - Fixed Type 160A - Fixed Type 200A - Fixed Type 250A - Fixed Type 300A - Fixed Type 400A - Fixed Type 63A - Drawout Type 125A - Drawout Type 160A - Drawout Type 200A - Drawout Type 250A - Drawout Type 300A - Drawout Type 400A - Drawout Type 220V Dcdb Buscoupler - Module Type - Dc 50A - Dc Fixed Type 100A - Dc Fixed Type 125A - Dc Fixed Type 150A - Dc Fixed Type 200A - Dc Fixed Type 300A - Dc Fixed Type 400A - Dc Fixed Type 450A - Dc Fixed Type 500A - Dc Fixed Type 630A - Dc Fixed Type 800A - Dc Fixed Type 1000A - Dc Fixed Type 1250A - Dc Fixed Type 1600A - Dc Fixed Type 50A - Dc Drawout Type 100A - Dc Drawout Type 125A - Dc Drawout Type 150A - Dc Drawout Type 200A - Dc Drawout Type 300A - Dc Drawout Type 400A - Dc Drawout Type 450A - Dc Drawout Type 500A - Dc Drawout Type 630A - Dc Drawout Type 800A - Dc Drawout Type 1000A - Dc Drawout Type 1250A - Dc Drawout Type 1600A - Dc Drawout Type 220V Dcdb Tie - Module Type - Hd 50A - Hd Fixed Type 100A - Hd Fixed Type 125A - Hd Fixed Type 150A - Hd Fixed Type 200A - Hd Fixed Type 300A - Hd Fixed Type 400A - Hd Fixed Type 450A - Hd Fixed Type 500A - Hd Fixed Type 630A - Hd Fixed Type 800A - Hd Fixed Type 1000A - Hd Fixed Type 1250A - Hd Fixed Type 1600A - Hd Fixed Type 50A - Hd Drawout Type 100A - Hd Drawout Type 125A - Hd Drawout Type 150A - Hd Drawout Type 200A - Hd Drawout Type 300A - Hd Drawout Type 400A - Hd Drawout Type 450A - Hd Drawout Type 500A - Hd Drawout Type 630A - Hd Drawout Type 800A - Hd Drawout Type 1000A - Hd Drawout Type 1250A - Hd Drawout Type 1600A - Hd Drawout Type , Acb Outgoing Supply Feeder - Module Type Dae (O/G)/Dae-Tie 630A 800A 1000A 1250A 1600A 2000A 2500A 3000A 4000A , Acb Outgoing Motor Feeder - Module Type Dm/Pm/Am (Controlled From Ddcmis/Plc/Atrs) 90- 200Kw , Mccb Outgoing Supply Feeders Module Type E3(O/G) 16A - Fixed Type 32A - Fixed Type 63A - Fixed Type 100A - Fixed Type 125A - Fixed Type 160A - Fixed Type 200A - Fixed Type 250A - Fixed Type 300A - Fixed Type 400A - Fixed Type 16A - Drawout Type 32A - Drawout Type 63A - Drawout Type 100A - Drawout Type 125A - Drawout Type 160A - Drawout Type 200A - Drawout Type 250A - Drawout Type 300A - Drawout Type 400A - Drawout Type Module Type E3-Tp (O/G) 16A - Fixed Type 32A - Fixed Type 63A - Fixed Type 100A - Fixed Type 125A - Fixed Type 160A - Fixed Type 200A - Fixed Type 250A - Fixed Type 300A - Fixed Type 400A - Fixed Type 16A - Drawout Type 32A - Drawout Type 63A - Drawout Type 100A - Drawout Type 125A - Drawout Type 160A - Drawout Type 200A - Drawout Type 250A - Drawout Type 300A - Drawout Type 400A - Drawout Type Module Type Es3 (O/G) 63A - Fixed Type 100A - Fixed Type 125A - Fixed Type 160A - Fixed Type 200A - Fixed Type 250A - Fixed Type 400A - Fixed Type 63A - Drawout Type 100A - Drawout Type 125A - Drawout Type 160A - Drawout Type 200A - Drawout Type 250A - Drawout Type 400A - Drawout Type 2-Ph Feeder Module Type E2(O/G) 100A - Fixed Type 160A - Fixed Type 200A - Fixed Type 250A - Fixed Type 300A - Fixed Type 400A - Fixed Type 100A - Drawout Type 160A - Drawout Type 200A - Drawout Type 250A - Drawout Type 300A - Drawout Type 400A - Drawout Type Double Pole 1-Ph Feeder Module Type E1(O/G) 16A - Fixed Type 32A - Fixed Type 63A - Fixed Type 100A - Fixed Type 125A - Fixed Type 16A - Drawout Type 32A - Drawout Type 63A - Drawout Type 100A - Drawout Type 125A - Drawout Type 3-Ph Mccb Controlled Outgoing Contactor Feeder With Imc Module Type Ea3(O/G) 16A - Fixed Type 32A - Fixed Type 63A - Fixed Type 100A - Fixed Type 125A - Fixed Type 200A - Fixed Type 250A - Fixed Type 400A - Fixed Type 16A - Drawout Type 32A - Drawout Type 63A - Drawout Type 100A - Drawout Type 125A - Drawout Type 200A - Drawout Type 250A - Drawout Type 400A - Drawout Type 3-Ph Mccb Controlled Outgoing Contactor Feeder Without Imc Module Type Et3(O/G) 16A - Fixed Type 32A - Fixed Type 63A - Fixed Type 100A - Fixed Type 125A - Fixed Type 200A - Fixed Type 250A - Fixed Type 400A - Fixed Type 16A - Drawout Type 32A - Drawout Type 63A - Drawout Type 100A - Drawout Type 125A - Drawout Type 200A - Drawout Type 250A - Drawout Type 400A - Drawout Type 1-Ph Mccb Controlled Outgoing Contactor Feeder Module Type Ea1(O/G) 16A - Fixed Type 32A - Fixed Type 63A - Fixed Type 16A - Drawout Type 32A - Drawout Type 63A - Drawout Type 220V Dc Outgoing Mccb Type (X) Feeder 16A - Fixed Type 32A - Fixed Type 63A - Fixed Type 100A - Fixed Type 125A - Fixed Type 200A - Fixed Type 250A - Fixed Type 300A - Fixed Type 400A - Fixed Type 600A - Fixed Type 800A - Fixed Type 16A - Drawout Type 32A - Drawout Type 63A - Drawout Type 100A - Drawout Type 125A - Drawout Type 200A - Drawout Type 250A - Drawout Type 300A - Drawout Type 400A - Drawout Type 600A - Drawout Type 800A - Drawout Type , Dol Motor Starter - Unidirectional Drive - Drawout Type Module Type Dk2 / Pk2 / Ak2 (Controlled From Ddcmis/Plc/Atrs) Upto 5.5Kw 5.6 - 7.0Kw 7.1 - 13Kw 13.1 - 24Kw 24.1 - 29.9Kw Module Type Dk21 / Pk21 / Ak21 (Controlled From Ddcmis/Plc/Atrs) 30.0 - 37.0Kw 37.1 - 55Kw 55.1 - 80.0Kw 80.1 - 89.9Kw Module Type Dk2e/Pk2e/Ak2e (Reacceleration) (Controlled From Ddcmis/Plc/Atrs) Upto 5.5Kw 5.6 - 7.0Kw 7.1 - 13Kw 13.1 - 24Kw 24.1 - 29.9Kw Module Type Dk21e/Pk21e/Ak21e (Reacceleration) (Controlled From Ddcmis/Plc/Atrs) 30.0 - 37.0Kw 37.1 - 55Kw 55.1 - 80.0Kw 80.1 - 89.9Kw Module Type K2 (Controlled From Lcp) Upto 5.5Kw 5.6 - 7.0Kw 7.1 - 13Kw 13.1 - 24Kw 24.1 - 29.9Kw Module Type K21 (Controlled From Lcp) 30.0 - 37.0Kw 37.1 - 55Kw 55.1 - 80.0Kw 80.1 - 89.9Kw Module Type K3 (Controlled From Lpbs) Upto 5.5Kw 5.6 - 7.0Kw 7.1 - 13Kw 13.1 - 24Kw 24.1 - 29.9Kw Module Type K31 (Controlled From Lpbs) 30.0 - 37.0Kw 37.1 - 55Kw 55.1 - 80.0Kw 80.1 - 89.9Kw , Rdol Motor Starter - Bidirectional Drive - Drawout Type Module Type Dn1/ Pn1/ An1 (Controlled From Ddcmis/Plc/Atrs) Upto 5.5Kw 5.6 - 7.0Kw 7.1 - 13Kw 13.1 - 24Kw 24.1 - 29.9Kw 30.0 - 37.0Kw 37.1 - 55Kw 55.1 - 80.0Kw 80.1 - 89.9Kw , ?Rapping Motor (Rm1) Module With Imc , ?Rapping Motor (Rm2) Module With Olr , ?Dust Density Monitor (Ddm) Module , ?Hopper Heater (Hh) Module , ?Support Insulator Heater (Hi) Module , ?Shaft Insulator Heater (Hs) Module , Ash Level Indicator (Ali) Module , Areca Marshaling (Areca) Module , Wave Level Transmitter (Wlt) Module , Marshaling Module For Sspb Of Rapping Motor And Hopper Heater Feedback (Mm) , Wall Blower Module , Lane Road Blower Module , Ah Blower Module , Jamming Relay Module , Wireless Temperature Sensor (Wts1) Module (In One Acb/Pcc Panel With Single Acb) , Wireless Temperature Sensor (Wts2) Module (In One Acb Panel With Double Acb) , Wireless Temperature Sensor (Wts3) Module (In One Double Front Mcc Panel) , Common Auxiliary Module Pt Module Bus Pt Module For Pcc/Pmcc - G1 Type Bus Pt Module For Emergency Mcc - G2 Type Bus Pt Module For Mcc/Acdb - Vm Type Bus Pt Dcdb - S Type 110V Ac Control Supply Module - Type Cs (Consisting Of 415/110V Control Trafo.) 1Kva 2Kva 2.5Kva 3Kva 5Kva 7.5Kva 10Kva 240 V Ac Control Supply Module - Type Cs (Consisting Of 415/240V Control Trafo.) 1Kva 2Kva 2.5Kva 3Kva 5Kva 7.5Kva 10Kva 24V Ac Control Supply Module - Type Cs (Consisting Of 415/24V Control Trafo.) 250Va 500Va 1Kva 2Kva 2.5Kva 3Kva 5Kva 7.5Kva 10Kva 240V Ac Motor Space Heater Module 220V Dc Supply Module (For Receiving 220V Dc Supply) 24V Dc Supply Module 24 V Winding Heating Module Alarm Module Test Supply Module 240 V Ac Panel Space Heating Supply Module - Type Sh (Consisting Of 415/240V Control Trafo.) 1Kva 2Kva 2.5Kva 3Kva 5Kva 7.5Kva 10Kva 240V Ac Space Heater Supply Module- Shs Y-Link , Empty Panel With Horizontal & Vertical Busbar, Support & Auxiliary Busbar (4 Wire System) Plain Cement Concrete Panel (Single Front Drawout Type) Without Temperature Sensor 630 / 630A 1000 / 1000A 1250 / 1250A 1600 / 1600A 2000 / 2000A 2500 / 2500A 3000 / 3000A 4000 / 4000A Mcc Panel (Single Front Fixed Type ) 63 / 63A 250 / 250A 400 / 400A 630 / 630A 800 / 630A 1000 / 630A 1250 / 630A 1600 / 630A 2000 / 630A 2500 / 630A 3000 / 630A 4000 / 630A Mcc Panel (Single Front Drawout Type) 63 / 63A 250 / 250A 400 / 400A 630 / 630A 800 / 630A 1000 / 630A 1250 / 630A 1600 / 630A 2000 / 630A 2500 / 630A 3000 / 630A 4000 / 630A Mcc Panel (Double Front Drawout Type) 63 / 63A 250 / 250A 400 / 400A 630 / 630A 800 / 630A 1000 / 630A 1250 / 630A 1600 / 630A 2000 / 630A 2500 / 630A 3000 / 630A 4000 / 630A Acdb Panel (Double Front Fixed Type) 250 / 250A 400 / 400A 630 / 250A 630 / 630A 220V Dcdb Panel (Single Front Fixed Type) With 20Ka, 1 Second Fault Level Upto 125A (With 125A Vbb) Upto 630A (With 630A Vbb) 1000A (With 630A Vbb) 1600A (With 630A Vbb) 220V Dcdb Panel (Single Front Fixed Type) With 40Ka, 1 Second Fault Level Upto 125A (With 125A Vbb) Upto 630A (With 630A Vbb) 1000A (With 630A Vbb) 1600A (With 630A Vbb) 220V Dcdb Panel (Double Front Fixed Type) With 20Ka, 1 Second Fault Level Upto 125A (With 125A Vbb) Upto 630A (With 630A Vbb) 1000A (With 630A Vbb) 1250A (With 630A Vbb) 1600A (With 630A Vbb) 220V Dcdb Panel (Double Front Fixed Type) With 40Ka, 1 Second Fault Level Upto 125A (With 125A Vbb) Upto 630A (With 630A Vbb) 1000A (With 630A Vbb) 1250A (With 630A Vbb) 1600A (With 630A Vbb) 48V Dcdb Panel (Single Front Fixed Type) Upto 125A (With 125A Vbb) Upto 200A (With 200A Vbb) Upto 630A (With 630A Vbb) 48V Dcdb Panel (Double Front Fixed Type) Upto 125A (With 125A Vbb) Upto 200A (With 200A Vbb) Upto 630A (With 630A Vbb) Empty Acb Panel With Horizontal & Vertical Busbar, Support & Auxiliary Busbar 630 / 630A 800 / 630A 800 / 800A 1000 / 630A 1000 / 800A 1000 / 1000A 1250 / 630A 1250 / 800A 1250 / 1000A 1250 / 1250A 1600 / 630A 1600 / 800A 1600 / 1000A 1600 / 1250A 1600 / 1600A 2000 / 630A 2000 / 800A 2000 / 1000A 2000 / 1250A 2000 / 1600A 2000 / 2000A 2500 / 630A 2500 / 800A 2500 / 1000A 2500 / 1250A 2500 / 1600A 2500 / 2000A 2500 / 2500A 3000 / 630A 3000 / 800A 3000 / 1000A 3000 / 1250A 3000 / 1600A 3000 / 2000A 3000 / 2500A 3000 / 3000A 4000 / 630A 4000 / 800A 4000 / 1000A 4000 / 1250A 4000 / 1600A 4000 / 2000A 4000 / 2500A 4000 / 3000A 4000 / 4000A , Empty Panel With Horizontal & Vertical Busbar, Support & Auxiliary Busbar (3 Wire System) Plain Cement Concrete Panel (Single Front Drawout Type) Without Temperature Sensor 2000 / 2000A 3000 / 3000A Mcc Panel (Double Front Drawout Type) 2000 / 630A 3000 / 630A Acdb Panel (Double Front Fixed Type) 250 / 250A 400 / 400A Empty Acb Panel With Horizontal & Vertical Busbar, Support & Auxiliary Busbar 2000 / 630A 2000 / 800A 2000 / 1000A 2000 / 1250A 2000 / 1600A 2000 / 2000A 3000 / 630A 3000 / 800A 3000 / 1000A 3000 / 1250A 3000 / 1600A 3000 / 2000A 3000 / 2500A 3000 / 3000A , Dummy Panel Upto 630A 800A 1000A 1250A 1600A 2000A 2500A 3000A 4000A , Unit Prices For Circuit Components Air Circuit Breaker Without Releases 630A Acb, 4P, Edo, Ac 800A Acb, 4P, Edo, Ac 1000A Acb, 4P, Edo, Ac 1250A Acb, 4P, Edo, Ac 1600A Acb, 4P, Edo, Ac 2000A Acb, 4P, Edo, Ac 2500A Acb, 4P, Edo, Ac 3000A Acb, 4P, Edo, Ac 4000A Acb, 4P, Edo, Ac 630A Acb, 3P, Edo, Ac 800A Acb, 3P, Edo, Ac 1000A Acb, 3P, Edo, Ac 1250A Acb, 3P, Edo, Ac 1600A Acb, 3P, Edo, Ac 2000A Acb, 3P, Edo, Ac 2500A Acb, 3P, Edo, Ac 3000A Acb, 3P, Edo, Ac 4000A Acb, 3P, Edo, Ac 800A Acb, 2P, Mdo, Dc 1000A Acb, 2P, Mdo, Dc 1250A Acb, 2P, Mdo, Dc 1600A Acb, 2P, Mdo, Dc Mpcb, Short-Circuit Release 16A 25A 32A 63A 80A 115A 150A Tp Mccb, 2No+2Nc Aux, Fsc & O/L Release 16A 25A 32A 63A 100A 125A 160A 200A 250A 315A 400A Tp Mccb, 2No+2Nc Aux, Adj S/C & O/L Release 16A 25A 32A 63A 100A 125A 160A 200A 250A 315A 400A Tp Mccb With Lsig Release 200A 250A 300A 350A 400A Tp Mccb - Motorized With Lsig Release 200A 250A 300A 350A 400A Power Contactor (Ac) ( With 2No & 2Nc Minimum) 16A 25A 32A 63A 80A 115A 150A 185A 265A 315A 400A Power Contactor (Dc) ( With 2No & 2Nc Minimum) 16A 25A 32A 63A 80A 115A 150A 185A 265A 400A Ac Aux. Contactor With 2No + 2Nc 3No + 3Nc 4No + 4Nc 6No + 6Nc Dc Aux. Contactor With 2No + 2Nc 3No + 3Nc 4No + 4Nc 6No + 6Nc Protection Relay Vagm 23 Ctu 12 Ctu 32 Vtt 11 Vag 11 Vaa 11 Vajhm 13 Vajhm 23 Cdgm-12 Cag 12 Cag 34 Ccum 21 Cdg 11 Cdg 31 Cdg 61 Vdg 14 Cdv 62 Cag 14 Vax 31 Cag 37 Caem-21 Vag-21 Vajc-11 Ctmm-501 Motpro Vaa21 Vtt12 Vtig Vtu21 Numerical Relay For Phase Over Current Protection (50/51), Earth Fault Protection (50N/51N), Stand By Earth Fault Protection (51Ns), Restricted Earth Fault Protection (64R), Bus No Volt, Fault Lockout Function (86), Under Voltage With Timer (27M), Synchronising Check Function (25, Circuit Breaker Failure (50Bf), Relay Self Supervision, Circuit Breaker Condition Monitoring, Trip Circuit Supervision (95), Current Tranformer Supervision, Voltage Tranformer Supervision, Breaker Control With I/L, Disturbance Recording, Fault Recording, Event Recording, Measurement Functions (3I, Io, 3U, Uo, Hz, P, Q, E, Pf) Sef Numerical Relay Numerical Relay For Phase Over Current Protection (50/51), Earth Fault Protection (50N/51N), Stand By Earth Fault Protection (51Ns), Restricted Earth Fault Protection (64R), Bus No Volt, Fault Lockout Function (86), Under Voltage With Timer (27M), Synchronising Check Function (25, Circuit Breaker Failure (50Bf), Relay Self Supervision, Circuit Breaker Condition Monitoring, Trip Circuit Supervision (95), Current Tranformer Supervision, Voltage Tranformer Supervision, Breaker Control With I/L, Disturbance Recording, Fault Recording, Event Recording, Measurement Functions (3I, Io, 3U, Uo, Hz, P, Q, E, Pf), Measurement And Display Of Harmonic Contect Of Voltage & Current Numerical Relay For Phase Over Current Protection (50/51), Earth Fault Protection (50N/51N), Bus No Volt, Fault Lockout Function (86), Under Voltage With Timer (27M), Synchronising Check Function (25, Circuit Breaker Failure (50Bf), Relay Self Supervision, Circuit Breaker Condition Monitoring, Trip Circuit Supervision (95), Current Tranformer Supervision, Voltage Tranformer Supervision, Breaker Control With I/L, Disturbance Recording, Fault Recording, Event Recording, Measurement Functions (3I, Io, 3U, Uo, Hz, P, Q, E, Pf) Numerical Relay For Phase Over Current Protection (50/51), Earth Fault Protection (50N/51N), Restricted Earth Fault Protection (64R), Bus No Volt, Fault Lockout Function (86), Under Voltage With Timer (27M), Synchronising Check Function (25, Circuit Breaker Failure (50Bf), Differential Protection (87) (High Impedance), Reverse Power Protection, Dg Neutral Displacement (59), Dg Monitoring, Relay Self Supervision, Circuit Breaker Condition Monitoring, Trip Circuit Supervision (95), Current Tranformer Supervision, Voltage Tranformer Supervision, Breaker Control With I/L, Disturbance Recording, Fault Recording, Event Recording, Measurement Functions (3I, Io, 3U, Uo, Hz, P, Q, E, Pf) Numerical Relay For Phase Over Current Protection (50/51), Earth Fault Protection (50N/51N), Stalling/ Locked Rotor Protection (50L/R), Thermal Overlaod Protection (49), Negative Phase Sequence Protection (46), Bus No Volt, Repetative Start Protection (66), Fault Lockout Function (86), Under Voltage With Timer (27M), Motor Differential Protection (87M), Circuit Breaker Failure (50Bf), Phase Reversal Protection (46R), Current Unbalance Protection, Relay Self Supervision, Circuit Breaker Condition Monitoring, Trip Circuit Supervision (95), Current Tranformer Supervision, Voltage Tranformer Supervision, Breaker Control With I/L, Disturbance Recording, Fault Recording, Event Recording, Measurement Functions (3I, Io, 3U, Uo, Hz, P, Q, E, Pf) Numerical Check Synchronising Relay Check Synchronising Relay Type-Ske11 Or Better Guard Relay Battery Earth Fault Relay, 1-7Ma, Nominal Voltage-220V Dc, 1Dv, 2No special repair Flush Overload Relay, Nominal Voltage-220V Dc, O/V Vltage Setting-110%, 1/4Nv, 1No+1Nc special repair Under Voltage Relay, Nominal Voltage-220V Dc, U/V Setting-80%, Aux..-240V Ac, 1/2Nh, 1No+2Nc special repair Battery Earth Fault Relay, 1-7Ma, Nominal Voltage-48V Dc, 1Dv, 2No special repair Flush Overload Relay, Nominal Voltage-48V Dc, O/V Vltage Setting-110%, 1/4Nv, 1No+1Nc special repair Under Voltage Relay, Nominal Voltage-48V Dc, U/V Setting-80%, Aux..-240V Ac, 1/2Nh, 1No+2Nc special repair Jamming Relay Electronic Type Jamming Relay Imc & Its Modules For Unidirectional Drive , Imc Upto 5.5Kw , Current Sensing Module For Above (If Not Integral In Imc Module) , Imc For 5.6 - 7.0Kw , Current Sensing Module For Above (If Not Integral In Imc Module) , Imc For 7.1 - 13Kw , Current Sensing Module For Above (If Not Integral In Imc Module) , Imc For 13.1 - 24Kw , Current Sensing Module For Above (If Not Integral In Imc Module) , Imc For 24.1 - 29.9Kw , Current Sensing Module For Above (If Not Integral In Imc Module) , Imc For 30.0 - 37.0Kw , Current Sensing Module For Above (If Not Integral In Imc Module) , Voltage Sensing Module For Above (If Not Integral In Imc Module) , Imc For 37.1 - 55Kw , Current Sensing Module For Above (If Not Integral In Imc Module) , Voltage Sensing Module For Above (If Not Integral In Imc Module) , Imc For 55.1 - 80.0Kw , Current Sensing Module For Above (If Not Integral In Imc Module) , Voltage Sensing Module For Above (If Not Integral In Imc Module) , Imc For 80.1 - 89.9Kw , Current Sensing Module For Above (If Not Integral In Imc Module) , Voltage Sensing Module For Above (If Not Integral In Imc Module) , Expansion Module For Imc Timer (Dc) On Delay Timer, 0.5-5Sec., 220V Dc, 2No+2Nc On Delay Timer, 1.0-10Sec. 220V Dc, 2No+2Nc 240Vac Mtr Restart Control Timer (.2-60Secs) 240Vac On Delay Timer(1-10Secns)With 1No 220Vdc On Delay Timer(.5-5Secs) With 1No 220Vdc 0N Delay Timer(0.5-5Secs)With 3No 220Vdc On Delay Timer(1-10Secs) With 3No Meter Ac Ammeter (Digital) Ac Ammeter (Analog) Linear Scale Ac Ammeter (Analog) Compressed Scale Dc Ammeter (Digital) Dc Ammeter (Analog) Dc Ammeter With Shunt And Center Zero Ac Voltmeter (Digital) Dc Voltmeter (Analog) Wattmeter (3 Phase) Wattmeter (1 Phase) Tvm Meter Digital Energy Meter Frequency Meter Synchroscope Differential Voltmeter Differential Frequency Meter Multifunction Digital Energy Meter With Rs485 Port (0.2 Acc. Class) Multifunction Digital Energy Meter With Rs485 Port (0.5 Acc. Class) Multifunction Digital Energy Meter With Rs485 Port (1.0 Acc. Class) Single Phase Preventor Relay Mcb 6A, 4P 415V Ac 10A, 4P 415V Ac 16A, 4P 415V Ac 6A Dp, 240V Ac 10A Dp, 240V Ac 16A Dp, 240V Ac 32A Dp, 240V Ac 6A Dp, 110V Ac 10A Dp, 110V Ac 16A Dp, 110V Ac 32A Dp, 110V Ac 6A Dp, 220V Dc 10A Dp, 220V Dc 16A Dp, 220V Dc 6A Sp, 240V Ac 10A Sp, 240V Ac 16A Sp, 240V Ac 32A Sp, 240V Ac 6A Sp, 110V Ac 10A Sp, 110V Ac 16A Sp, 110V Ac 32A Sp, 110V Ac 6A Sp, 220V Dc 10A Sp, 220V Dc 16A Sp, 220V Dc Switch & Push Button Breaker Control Switch, 16A,220V Dc, 2Close+2Trip Dc Isolating Switch 16A,220V Dc, Dp, Base Mtg. 16A, 240V Ac Selector Switch 3Way, 4Pole, Flush Mtg 25A, 240V Ac Selector Switch 3Way, 4Pole, Flush Mtg 16A, 240V Ac Selector Switch 2Way, 2Pole, Flush Mtg Normal/ Trial Sel. Switch, 2Pole , 2Way, 10A 240V Ac, Flush Mtg, Mcc/ Normal/ Trial Sel. Switch, 2Pole ,3Way, 10A 240V Ac, Flush Mtg Swgr/ Remote Sel. Switch 3Pole 2Way,16A 220V Dc, Flush Mtg Swgr/ Normal/ Trial Sel. Switch, 3Pole, 3Way, 16A 220V Dc, Flush Mtg. Normal/ Trial Sel. Switch, 2Pole , 2Way, 10A 240V Ac, Flush Mtg, Lockabel Type Mcc/ Normal/ Trial Sel. Switch, 2Pole ,3Way, 10A 240V Ac, Flush Mtg, Lockabel Type Swgr/ Remote Sel. Switch 3Pole 2Way,16A 220V Dc, Flush Mtg.Lockable Type Swgr/ Normal/ Trial Sel. Switch, 3Pole, 3Way, 16A 220V Dc, Flush Mtg., Lockable Type Ammeter Selector Switch Voltmeter Selector Switch Toggle Switch 5A, 240V Ac Ac Switch Spst-5A,240V Ac 10A, 220V Dc Switch Door Limit Switch Ammeter Selector Switch Voltmeter Selector Switch Synchronisation Selector Switch Trip Selector Switch Push Button 2No + 2Nc Shrouded 1No + 1Nc Shrouded 2No + 2Nc Mushroom Head Stayput 2No + 2Nc Lockable Type Indicating Lamp Assembly (Led Type) 240V Ac-Green 240V Ac-Red 240V Ac- Amber 110V Ac-Green 110V Ac-Red 110V Ac- Amber 220V Dc-White 220V Dc-Red 220V Dc-Green 220V Dc-Blue 220V Dc- Amber 63.5V Ac-Red 63.5V Ac-Yellow 63.5V Ac-Blue Ct Metering Ct Upto 75/1A 100/1A 125/1A 150/1A 200/1A 250/1A 300/1A 400/1A 500/1A 630/1A 800/1A 1000/1A 1250/1A 1600/1A 2000/1A 2500/1A 3000/1A 4000/1A Protection Ct (5P20) Upto 75/1A 100/1A 125/1A 150/1A 200/1A 250/1A 300/1A 400/1A 500/1A 630/1A 800/1A 1000/1A 1250/1A 1600/1A 2000/1A 2500/1A 3000/1A 4000/1A 630/5A 800/5A 1000/5A 1250/5A 1600/5A 2000/5A 2500/5A 3000/5A 4000/5A Ps Class Ct 1000/1A 1600/1A 2000/1A 2500/1A 3000/1A 4000/1A 1000/5A 1600/5A 2000/5A 2500/5A 3000/5A 4000/5A Voltage Transformer 415/v3 : 110/v 3V, 50Va 415/v3 : 110/v3 V, 100Va 415/v3 : 240/v3 V, 50Va 415/v3 : 240/v3 V, 100Va 415 : 110V, 50Va 415 : 110V, 100Va 415 : 240V, 50Va 415 : 240V, 100Va Toggle Switch (16A) Secondary Isolating Contact Block Control Terminal (Fixed) Control Terminal (Drawout) Thermostat, Dial Type Control Transformer 415/240V,Cl-B, 1 Kva 415/240V,Cl-B, 2Kva 415/240V,Cl-B, 2.5Kva 415/240V,Cl-B, 3Kva 415/240V,Cl-B, 5Kva 415/240V,Cl-B, 7.5Kva 415/240V,Cl-B, 10Kva 415/110V,Cl-B, 1 Kva 415/110V,Cl-B, 2Kva 415/110V,Cl-B, 2.5Kva 415/110V,Cl-B, 3Kva 415/110V,Cl-B, 5Kva 415/110V,Cl-B, 7.5Kva 415/110V,Cl-B, 10Kva 415/110V,Cl-B, 10Kva 4-20Ma Dual O/P, Aux Sup 220V Dc, 1A, Current Transducer 4-20Ma Dual O/P, Aux Sup 240V Ac, 1A, Current Transducer 4-20Ma Dual O/P, Aux Sup 110V Ac, 1A, Current Transducer 4-20Ma Dual O/P, Aux Sup 220V Dc, Voltagetransducer, Ptr 415/110V 4-20Ma Dual O/P, Aux Sup 240V Ac, Voltagetransducer, Ptr 415/110V 4-20Ma Dual O/P, Aux Sup 110V Ac, Voltagetransducer, Ptr 415/110V 4-20Ma Dual O/P, Aux Sup 220V Dc, Frequencytransducer, Ptr 415/110V 4-20Ma Dual O/P, Aux Sup 220V Dc, Input 0-75Mv Dc, Current Transducer-Dc 4-20Ma Dual O/P, Aux Sup 240V Ac, Input Voltage 0-220V Dc, Voltage Transducer-Dc 4-20Ma Dual Output Kw Transducer 4-20Ma Dual Output Kva Transducer 4-20Ma Dual Output providing fixing Transducer 4-20Ma Dual Output Frequency Transducer Interposing Relay Re 302 Or Eqvt With Freewheeling Diode & Led 3 Pin Socket - 5A, 110V Ac, 3Pin Space Heater Neutral Link With Mounting Assembly 20A For Control Ckt. & Power Ckt. Upto 25A Mccb Rating 32A For 50A Mccb Rating 63A For 100A & 125A Mccb Rating 125A For 250A Mccb Rating 250A For 400A & 500A Mccb Rating Castle Key Interlock For Mccb - 3Lock+2Key Mechanical Interlock For Power Contactor 16A 25A 32A 63A 80A 115A 150A 185A 265A 315A 400A Addon Block For Contactor 2No+2Nc 3No+1Nc 1No + 1Nc 1No 1Nc Isolating Transformer Isolating Transformer-15Kva Isolating Transformer-20Kva Isolating Transformer-25Kva Isolating Transformer-30Kva Isolator With Handle 16A 32A , Foundation Frame Mcc Panel Upto 1600A (Sf) 2500A (Sf) 3000A (Sf) 4000A (Sf) Upto 1600A (Df) 2500A (Df) 3000A (Df) 4000A (Df) 220V Dcdb Panel Sf Df Plain Cement Concrete / Pmcc Panel Upto 1600A 2000A 2500A 3000A 4000A , Connection From Pmcc/Mcc Panel To Pmcc/Mcc Panel 250A 400A 630A 800A 1000A 1200A 1600A 2000A 2500A 3000A 4000A , Cable Glands & Lugs: Single Compression Cable Glands For Cable Sizes: 2C X 2.5 Sq. Mm. 3C X 2.5 Sq. Mm. 5C X 2.5 Sq. Mm. 7C X 2.5 Sq. Mm. 10C X 2.5 Sq. Mm. 14C X 2.5 Sq. Mm. 2C X 10 Sq. Mm. 2C X 16 Sq. Mm. 2C X 25 Sq. Mm. 2C X 35 Sq. Mm. 2C X 50 Sq. Mm. 2C X 70 Sq. Mm. 2C X 95 Sq. Mm. 3C X 2.5 Sq. Mm. 3C X 10 Sq. Mm. 3C X 16 Sq. Mm. 3C X 25 Sq. Mm. 3C X 35 Sq. Mm. 3C X 50 Sq. Mm. 3C X 70 Sq. Mm. 3C X 95 Sq. Mm. 3C X 150 Sq. Mm. 3C X 240 Sq. Mm. 3C X 300 Sq. Mm. 3.5C X 25 Sq. Mm. 3.5C X 50 Sq. Mm. 3.5C X 70 Sq. Mm. 3.5C X 95 Sq. Mm. 3.5C X 240 Sq. Mm. 3.5C X 300 Sq. Mm. 4C X 16 Sq. Mm. 4C X 35 Sq. Mm. 1C X 300 Sq. Mm. 1C X 630 Sq. Mm. Double Compression Cable Glands For Cable Sizes: 2C X 2.5 Sq. Mm. 3C X 2.5 Sq. Mm. 5C X 2.5 Sq. Mm. 7C X 2.5 Sq. Mm. 12C X 2.5 Sq. Mm. 16C X 2.5 Sq. Mm. 2C X 10 Sq. Mm. 2C X 16 Sq. Mm. 2C X 25 Sq. Mm. 2C X 35 Sq. Mm. 2C X 50 Sq. Mm. 2C X 70 Sq. Mm. 2C X 95 Sq. Mm. 3C X 2.5 Sq. Mm. 3C X 10 Sq. Mm. 3C X 16 Sq. Mm. 3C X 25 Sq. Mm. 3C X 35 Sq. Mm. 3C X 50 Sq. Mm. 3C X 70 Sq. Mm. 3C X 95 Sq. Mm. 3C X 150 Sq. Mm. 3C X 240 Sq. Mm. 3C X 300 Sq. Mm. 3.5C X 25 Sq. Mm. 3.5C X 50 Sq. Mm. 3.5C X 70 Sq. Mm. 3.5C X 95 Sq. Mm. 3.5C X 240 Sq. Mm. 3.5C X 300 Sq. Mm. 4C X 16 Sq. Mm. 4C X 35 Sq. Mm. 1C X 300 Sq. Mm. 1C X 630 Sq. Mm. Cable Lugs For Sizes: 1.5 Sq. Mm. 2.5 Sq. Mm. 10 Sq. Mm. 16 Sq. Mm. 25 Sq. Mm. 35 Sq. Mm. 50 Sq. Mm. 70 Sq. Mm. 95 Sq. Mm. 120 Sq. Mm. 150 Sq. Mm. 185 Sq. Mm. 240 Sq. Mm. 300 Sq. Mm. 630 Sq. Mm. , Thermal O/L Relay With Spp - Olr Upto 5.5Kw 5.6 To 7.0Kw 7.1 To 13Kw 13.1 To 24Kw 24.1 To 29.9Kw 30.0 To 37.0Kw 37.1 To 55.0Kw 55.1 To 80.0Kw 80.1 To 89.9Kw , Heavy Duty Thermal O/L Relay With Spp - Olr Upto 5.5Kw 5.6 To 7.0Kw 7.1 To 13Kw 13.1 To 24Kw 24.1 To 29.9Kw 30.0 To 37.0Kw 37.1 To 55.0Kw 55.1 To 80.0Kw 80.1 To 89.9Kw , Daily 8 Hour Rate Deployed At Site: Engineer : (Per Day) , Module Name Plate , Wires For Secondary Wiring: 1.5 Sq. Mm. Per Meter 2.5 Sq. Mm. Per Meter 4.0 Sq. Mm. Per Meter , Control Terminal For Secondary Wiring Suitable For Cable Size: 0.5 Sq. Mm. 1.5 Sq. Mm. 2.5 Sq. Mm. , Electrical Junction Boxes (For Termination Of 0.5 Sqmm Screened Control Cables) 48 Ways 64 Ways 72 Ways 96 Ways , Ismc Channels Ismc 75 Channel Per Meter Ismc 100 Channel Per Meter , Temperature Sensor For Wireless Temperature Monitoring Sensor , Wireless Transmitter For Wireless Temperature Monitoring Sensor , Wireless Receiver For Wireless Temperature Monitoring Sensor , Additional Components (Except Networking Hardware Mentioned In Annexure B3) Required For Completeness Of Wireless Temperature Monitoring Sensor , Dp Mccb, Adj. Sc & O/L Release: 16A 25A 32A 63A 100A 125A 160A 200A , Tp Mccb Motor Duty Type With S/C Release: 16A 25A 32A 63A 100A 125A 160A 200A 250A 400A , Tp Mccb Adj S/C , O/L, E/F Release: 16A 25A 32A 63A 80A 100A 125A 160A 200A 250A 400A , Dc Mccb 16A 25A 32A 63A 80A 115A 150A 185A 265A 315A 400A , Switch Fuse Unit (Dc) - Dp Along With Fuse, Link Etc Complete (Suitable For 40Ka Fault Current) 16A 32A 63A 100A 125A 200A 250A 300A 400A 600A 800A , Switch Fuse Unit (Ac) - Tp Along With Fuse, Link Etc Complete 16A 32A 63A 100A 125A 200A 250A 300A 400A 600A 800A , Olm, Profibus Dp Connector Along With Accessories (At Y-Link End) For Interface Of Y-Link With Ddcmis. , Sp On/ Off Switch For Motor Space Heater Of Breaker Motor Fdr, 10A, 240V Ac , 4 Pole, 2 Posi., Selector Switch For Control Trf., 110V Ac , Extended Rotory Handle , Auxiliary Contact For Mccb 1C/O , Trip Contact For Mccb 1C/O , Control Terminals (Drawout) , 3 Pin Industrial Socket & Plug , Rotary On/Off Switch , Timer With 2C/O , Control Transformer, Dry Type, Cast Resin, 415/24V, Ins. Cl-B Or Better , Rectifier , Limit Switch (Breaker) , Ethernet Switch With 16 Copper Ports & 4 Fo Ports , Ethernet Switch With 08 Copper Ports & 4 Fo Ports , Cat5e/ Cat6 Ethernet Cable , Fibre Optic Patch Cord (Minimum Length - 10Metres) , 9 Windows Alarm Annunciation -1 , Electronic Hooter (96Sqmm) , Class 0.2S Accuracy Energy Meters Suitable For Abt Requirement (Specification In Annexure-I) The Bidder Should List The Unit Price For Any Additional Modules, Components, Or Items That Are Not Mentioned In The Above Specifications But May Be Necessary To Fulfill The Customers Requirements. Annexure - Ii Schedule Of Technical And Commercial Deviation Project:- 2X800 Mw Ntpc Singrauli Stpp Stage - Iii Package:-Lt Switchgear Tender Ref No - , Dated 02-05-2026 Name Of Vendor:- Sl No Voulme/ Section Page No. Clause No. Technical Specification/ Tender Document Complete Description Of Deviation Cost Of Withdrawl Of Deviation Reference Of Price Schedule On Which Cost Of Withdrawl Of Deviation Is Applicable Nature Of Cost Of Withdrawl Of Deviation (Positive/ Negative) Reason For Quoting Deviation Technical Deviations Commercial Deviations Particulars Of Bidders/ Authorised Representative Name Designations Sign & Date Notes: 1. Cost Of Withdrawl Of Deviation Will Be Applicable On The Basic Price (I.E. Excluding Taxes, Duties & Freight) Only. 2. All The Bidders Have To List Out All Their Technical & Commercial Deviations (If Any) In Detail In The Above Format. 3. Any Deviation Not Mentioned Above And Shown Separately Or Found Hidden In Offer, Will Not Be Taken Cognizance Of. 4. Bidder Shall Submit Duly Filled Unpriced Copy Of Above Format Indicating Quoted In Cost Of Withdrawl Of Deviation Column Of The Schedule Above Along With Their Techno-Commercial Offer, Wherever Applicable. In The Absence Of Same, Such Deviation(S) Shall Not Be Considered And Offer Shall Be Considered In Total Compliance To Nit. 5. Bidder Shall Furnish Price Copy Of Above Format Along With Price Bid. 6. The Final Decision Of Acceptance/ Rejection Of The Deviations Quoted By The Bidder Shall Be At Discretion Of The Purchaser. 7. Bidders To Note That Any Deviation (Technical/Commercial) Not Listed In Above And Asked After Part-I Opening Shall Not Be Considered. 8. For Deviations W.R.T. Credit Period, Liquidated Damages, Firm Prices If A Bidder Chooses Not To Give Any Cost Of Withdrawl Of Deviation Loading As Per Annexure-Vii, Will Apply. For Any Other Deviation Mentioned In Un-Priced Copy Of This Format Submitted With Part-I Bid But Not Mentioned In Priced Copy Of This Format Submitted With Priced Bid, The Cost Of Withdrawl Of Deviation Shall Be Taken As Nil. 9. Any Deviation Mentioned In Priced Copy Of This Format, But Not Mentioned In The Un-Priced Copy, Shall Not Be Considered. 10. All Techno-Commercial Terms And Conditions Of Nit Shall Be Deemed To Have Been Accepted By The Bidder, Other Than Those Listed In Unpriced Copy Of This Format. 11. Cost Of Withdrawl Is To Be Given Seperately For Each Deviation. In No Event Bidder Should Club Cost Of Withdrawl Of More Than One Deviation Else Cost Of Withdrawl Of Such Deviations Which Have Been Clubbed Together Shall Be Considered As Nil. 12. In Case Nature Of Cost Of Withdrawl (Positive/Negative) Is Not Specified It Shall Be Assumed As Positive. 13. In Case Of Descrepancy In The Nature Of Impact (Positive/ Negative), Positive Will Be Considered For Evaluation And Negative For Ordering.
|