Cpap Device Rental.Equipment Intended For The Home Treatment Of Obstructive Sleep Apnea And Hypopnea Syndrome, Providing Continuous Positive Pressure On The Airways, Keeping Them Open. Such As: Humifier, Nasal Cushion Mask With Head Support, Oronasal Mask With Containment Strips, Depending On Each Patients Need Or Prescription, Manuals, Trachea, Adapter And Carrying Bag. Warranty And Specialized Technical Assistance 24 Hours, 7 Days A Week, With Immediate Replacement Of The Equipment In Case Of Defect And Calibration Of Parameters, Replacement Scheduled Whenever The Limited Autonomy Of Hours Of The Equipment Is Reached., Oxygen Concentrator Device Rental. Minimum Specifications: Complete Oxygen Concentrator Device Rental, With The Following Technical Requirements: The Device Must Have Casters, Allowing Easy Movement, Flow Control Device, Increments With Flow Variation. 0.5 Liters To 5.0 Liters Per Minute - L/M, Equipped With Filters To Remove Dust, Bacteria And Other Particles, Alarm System To Indicate Defects And Intercurrences, Such As Pressure Drop, Electrical Power Failure, Low O2 Purity, O2 Concentration Outside The Parameters. Electrical Supply: Units Must Be Made Available For The 127V And Occasionally 220V Network. Low Noise Level. It Must Be Provided With Spare Accessories For Replacement When Necessary, And Assistance Must Be Provided Whenever The Health Department Requests: Oxygen Humidifier, Long Glasses-Type Nasal Cannula (Catheter) With Non-Toxic Siliconized Pvc Tube, Sterile, Approximately 2 Meters Long. Connection At The Ends In Pvc For Oxygen Therapy, Adjustable, Adult Size. It Must Be Accompanied By An Auxiliary Oxygen Cylinder, With At Least 1 Cubic Meter, To Be Kept Together With Each Concentrator For Use In The Event Of A Lack Of Electricity, Provided With Necessary Accessories For The Patients Movement, Such As A Regulating Valve, With Manometer And Flow Meter, Cart, Humidifier, Which When Supplied With The Set, The Cylinder ..., Bipap Type Device Rental Chronic Respiratory Diseases Or Patients With Neurodegenerative Diseases. The Device Must Allow Several Ventilation Modes Cpap, S, S/T, T And Pc, With A Pressure Range Of Ipap From 4 To 20 Cmh20, Epap From 4 To 25 Cmh20, Cpap From 4 To 20 Cmh20, Ventilation Ramp Adjustment Up To 45 Minutes. It Must Be Accompanied By Accessories / Components Such As A Humidifier, Nasal Pillow Mask With Head Support Or Oronasal Mask With Containment Strips, Trachea And Carrying Bag. The Device Must Be Light, Compact, Compatible With Direct Current - Dc And The Availability Of Connection To An External Battery, Which Must Be Accompanied By The Device. Warranty And 24-Hour Specialized Technical Assistance, With Immediate Replacement Of The Device In The Event Of A Defect And Calibration Of Parameters, Scheduled Replacement Whenever The Limit Of The Equipments Autonomy Of Hours
|