Luteinizing Hormone (Lh) Cassette For 100 Tests. Reagents For The Cobas E 411 Analyzer. Luteinizing Hormone (Lh) Cassette For 100 Tests. Purpose: Designed For Quantitative Determination Of Luteinizing Hormone In Human Serum And Plasma. Reagents And Working Solutions: The Lh Label Is Affixed To The Package Containing Basic Reagents. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 6.5 Ml: Streptavidin-Coated Microparticles, 0.72 Mg/Ml; Preservative R1 Anti-Lh Antibodies~Biotin (Gray Cap), 1 Bottle, 10 Ml: Biotinylated Monoclonal Anti-Lh Antibodies (Mouse) 2.0 Mg/L; Tris Buffer 50 Mmol/L, Ph 8.0; Preservative R2 Anti-Lh Antibodies~Ru(Bpy) (Black Cap), 1 Bottle, 10 Ml: Monoclonal Anti-Lh Antibodies (Mouse), Labeled With Ruthenium Complex, 0.3 Mg/L; Tris Buffer 50 Mmol/L, Ph 8.0; Preservative Storage Conditions: Unopened At 2-8 °C Until The End Of The Shelf Life. The Supplier Is Required To Provide A Certificate Of Origin Of The Goods. Delivery Area: For Eu Countries. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification., Herpes Simplex Virus Type 1 Immunoglobulin G (Hsv-1 Igg) Cassette (According To Technical Specification), Preparatory Reagent For Cyclosporine And Tacrolimus (Isd Sample Pretreatment). (According To Technical Specification), Antithyroglobulin Antibody (Anti-Tg) Cassette For 100 Tests. Reagents For The Cobas E 411 Analyzer. Antithyroglobulin Antibodies (Anti-Tg) Cassette For 100 Tests. Purpose: Immunoassay For In Vitro Quantitative Determination Of The Content Of Antibodies To Thyroglobulin In Human Serum And Plasma. Determination Of Anti-Tg Is Used As An Auxiliary Method For Diagnosing Autoimmune Thyroiditis. Reagents And Working Solutions: The A‑Tg Label Is Affixed To The Package Containing Basic Reagents. M Streptavidin-Coated Microparticles (Clear Cap), 1 Bottle, 12 Ml: Streptavidin-Coated Microparticles, 0.72 Mg/Ml; Preservative R1 Tg~Biotin (Gray Cap), 1 Bottle, 10 Ml: Biotinylated Tg (Human) 0.200 Mg/L; Tris Buffer 100 Mmol/L, Ph 7.0; Preservative R2 Anti‑Tg-Ab~Ru(Bpy) (Black Cap), 1 Bottle, 10 Ml: Monoclonal Anti-Tg Antibodies (Human) Labeled Ruthenium Complex 0.620 Mg/L; Tris Buffer 100 Mmol/L, Ph 7.0; Preservative Storage And Transportation Conditions: Store In The Refrigerator Strictly In An Upright Position. Shelf Life At 2‑8°C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10‑15°C 6 Weeks. Transportation Must Be In Thermal Containers With Cold Elements At A Temperature Of 2-8 °C Strictly In A Vertical Position, Not Subjected To Freezing Or Exposure To High Temperatures. Calibration Is Linear At Two Points, Calibration Frequency Is After Changing The Lot. Measuring Range 10.0-4000 Iu/Ml. The Lower Limit Of Detection Of The Test Is < 10.0 Iu/Ml. Test Reproducibility Is No More Than 4%. Reagents For The Cobas E601 Analyzer. The Supplier Is Required To Provide A Certificate Of Origin Of The Goods. Delivery Area: For Eu Countries. Remaining Shelf Life Of At Least 60%. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification., Cassette Antigen Tumor 125 (Ca 125) For 100 Tests. Reagents For The Cobas E 411 Analyzer. Cassette Tumor Antigen 125 (Ca 125) For 100 Tests. Purpose: Designed For Quantitative Determination Of Reactive Epitopes Of Os 125 In Human Serum And Plasma. Reagents And Working Solutions: The Ca125 Ii Label Is Affixed To The Package With Reagents. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 6.5 Ml: Streptavidin-Coated Microparticles, 0.72 Mg/Ml; Preservative R1 Anti-Ca 125 Antibody~Biotin (Gray Cap), 1 Bottle, 9 Ml: Biotinylated Monoclonal Anti-Ca 125 Antibody (M 11; Mice) 1 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 7.4; Preservative R2 Anti-Ca 125 Antibody~Ru(Bpy) (Black Cap), 1 Vial, 9 Ml: Monoclonal Anti-Ca 125 Antibody (Oc 125, Mice), Labeled With Ruthenium Complex 1 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 7.4; Preservative Storage Conditions: Unopened At 2-8 °C Until The End Of The Shelf Life. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods. Delivery Area: For Eu Countries. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification., Cleancell M 2X2 L Elecsys, Cobas E. Reagents For The Cobas E Analyzer. Purpose: System Solution For Cleaning The Measuring Device Immunological Analyzer Cobas E. Cleancell Is Used When Performing Tests Using Elecsys Reagents. The Cleancell Kit Can Be Used With All Reagent Series. Cleancell Is Used To Perform The Following Tasks: ▪ Cleaning The Pipe System And Measuring Cell After Each Measurement ▪ Preparation Of Electrodes. Reagents - Working Solutions: 2*2 L, Cleaning Solution For The Measuring Cell Koh 176 Mmol/L (Corresponds To Ph 13.2); Detergent ≤ 1%. Contents Are Ready For Use.*Injure At 15‑25 °C. Stability: Unopened At 15‑25 °C: Shelf Life On Board The Analyzer Is 4 Weeks. Upon Delivery, Present A Certificate Of Origin Of The Goods And A Power Of Attorney From The Manufacturer To Sell The Goods On The Territory Of The Republic Of Kazakhstan. Delivery Area: For Eu Countries. Remaining Shelf Life Of At Least 60%. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Availability Of A Document Confirming Delivery By A Potential Supplier Who Has The Status Of A Manufacturer Or An Official Representative Of The Manufacturer., Alpha Fetoprotein (Afp) Cassette 100 Tests. Reagents For The Cobas E 411 Analyzer. Alpha Fetoprotein (Afp) Cassette For 100 Tests. Purpose: Immunotest For In Vitro Diagnostics. Designed For Quantitative Determination Of Α1 Fetoprotein In Human Serum And Plasma. Reagents And Working Solutions: The Package Containing Basic Reagents Bears The Afp Label. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 6.5 Ml: Streptavidin-Coated Microparticles, 0.72 Mg/Ml; Preservative R1 Anti-Afp Antibodies~Biotin (Gray Cap), 1 Bottle, 10 Ml: Biotinylated Monoclonal Anti-Afp Antibodies (Mouse) 4.5 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 6.0; Preservative R2 Anti-Afp Antibodies~Ru(Bpy) (Black Cap), 1 Bottle, 10 Ml: Monoclonal Anti-Afp Antibodies (Mouse), Labeled With Ruthenium Complex 12.0 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 6.0; Preservative Storage And Transportation Conditions: Store In The Refrigerator Strictly In An Upright Position. Shelf Life At 2 8 °C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10 - 15 °C 8 Weeks. Transportation Must Be In Thermal Containers With Cold Elements At A Temperature Of 2-8 °C Strictly In A Vertical Position, Not Subjected To Freezing Or Exposure To High Temperatures. Calibration Is Linear At Two Points, Calibration Frequency Is 7 Days. Measuring Range 0.500-1000 Iu/Ml Or 0.605-1210 Ng/Ml (Determined By The Value Of The Lower Limit Of Detection And The Maximum Value Of The Master Calibration). Values Below The Detection Limit Are Displayed As <0.500 Iu/Ml Or <0.605 Ng/Ml. Values Above The Measurement Range Are Displayed As >1000 Iu/Ml Or >1210 Ng/Ml (Or Up To 50,000 Iu/Ml Or 60,500 Ng/Ml For 50-Fold Diluted Samples). Test Reproducibility Is No More Than 1.5%. The Supplier Is Required To Provide A Certificate Of Origin Of The Goods. Delivery Area: For Eu Countries. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification., Procell M 2X2 L Elecsys,Cobas E. Reagents For The Cobas E Analyzer. Purpose: System Reagent For Generating Electrochemical Signals On The Cobas E Immunochemical Analyzer. Procell Is Used In Conjunction With Elecsys Test Reagents. Procell Can Be Used With All Reagent Lots. Procell Is Used To Perform The Following Tasks: ▪ Bringing Electrodes To The Required Parameters ▪ Transporting The Reaction Mixture ▪ Washing Streptavidin-Coated Microparticles ▪ Generating A Signal. Reagents - Working Solutions: 2*2 L, Substrate Reagent Phosphate Buffer 300 Mmol/L; Tripropylamine 180 Mmol/L; Detergent ≤ 0.1%; Preservative, Ph 6.8. The Content Is Ready To Use. *Wound At 15‑25 °C. Stability: Unopened At 15‑25 °C: Shelf Life On Board The Analyzer Is 4 Weeks. Upon Delivery, Provide A Certificate Of Origin Of The Goods. Delivery Area: For Eu Countries. Remaining Shelf Life Of At Least 60%. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification., Immunoglobulin M Cassette To Cytomegalovirus For 100 Tests (Cmv Igm). (According To Technical Specification), Cassette Antigen Tumor 15-3 Ii (Ca 15-3 Ii) For 100 Tests. Reagents For The Cobas E 411 Analyzer. Cassette Tumor Antigen 15-3 Ii (Ca 15-3 Ii) For Cobas E, Elecsys Analyzers For 100 Tests. Purpose: Immunotest For In Vitro Diagnostics. Intended For The Quantitative Determination Of Ca 15‑3 In Human Serum And Plasma As An Auxiliary Procedure For Monitoring Patients With Breast Cancer. Reagents And Working Solutions: The Package Containing Basic Reagents Is Labeled Ca 15‑3 Ii. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 6.5 Ml: Streptavidin-Coated Microparticles, 0.72 Mg/Ml; Preservative R1 Anti-Ca 15-3-Antibody~Biotin (Gray Cap), 1 Vial, 10 Ml: Biotinylated Monoclonal Antibody (115D8; Mice) 1.75 Mg/L; Phosphate Buffer 20 Mmol/L, Ph 6.0; Preservative R2 Anti-Ca 15-3-Ab~Ru(Bpy) (Black Cap), 1 Vial, 10 Ml: Monoclonal Anti-Ca 15-3 Antibody (Df3, Mice), Labeled With Ruthenium Complex 10 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 7.0; Preservative Storage Conditions: Store At 2‑8 °C. Do Not Freeze. The Supplier Is Obliged To Provide A Certificate Of Origin Of The Goods, The Deadline For Replacing Low-Quality And Non-Conforming Goods: Within 3 Working Days. When Delivering The Goods, The Presence Of A Representative Of The Supplier Is Mandatory., Cortisol Cassette For 100 Tests. (According To Technical Specification), Immunoglobulin G Cassette To Cytomegalovirus (Cmv Igg) For 100 Tests. (According To Technical Specification), Cassette Antigen Tumor 72-4 (Ca 72-4) For 100 Tests. Reagents For The Cobas E 411 Analyzer. Cassette Tumor Antigen 72-4 (Ca 72-4) For 100 Tests. Purpose: Designed For The Quantitative Determination Of Ca 72 4 In Human Serum And Plasma. This Method Is Used In Particular For The Therapeutic Monitoring Of Gastric And Ovarian Carcinomas. Reagents And Working Solutions: The Package With Basic Reagents Is Labeled Ca72 4. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 6.5 Ml: Streptavidin-Coated Microparticles, 0.72 Mg/Ml; Preservative R1 Anti-Ca 72-4-Ab~Biotin (Gray Cap), 1 Bottle, 8 Ml: Biotinylated Monoclonal Anti-Ca 72-4 Antibody (Cc49; Mice), 1 Mg/L, Phosphate Buffer 100 Mmol/L, Ph 6.8; Preservative.R2 Anti-Ca 72-4-Ab~Ru(Bpy) (Black Cap), 1 Bottle, 8 Ml: Monoclonal Anti-Ca 72-4 Antibodies (B72.3; Mice), Labeled With Ruthenium Complex 6 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 6.8; Preservative Storage Conditions: Unopened At 2-8 °C Until The End Of The Shelf Life. The Supplier Is Required To Provide A Certificate Of Origin Of The Goods. Delivery Area: For Eu Countries. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification., Cassette Fragment Of Cytokeratin 19 (Cyfra 21-1) For 100 Tests. (According To Technical Specification), Estradiol Cassette For 100 Tests (According To Technical Specifications), Cuvettes And Tips (Assay Tip/Cup Elecsys Modular E170). (According To Technical Specification), Cassette Antigen Tumor 19-9 (Ca 19-9) For 100 Tests. Reagents For The Cobas E 411 Analyzer. Tumor Antigen 19-9 (Ca 19-9) Cassette For Cobas E, Elecsys Analyzers For 100 Tests. Purpose: Designed For The Quantitative Determination Of Ca 19 9 In Human Serum And Plasma. Reagents And Working Solutions: The Package With Basic Reagents Is Labeled Ca19 9. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 6.5 Ml: Streptavidin-Coated Microparticles, 0.72 Mg/Ml; Preservative R1 Anti-Ca 19-9-Ab~Biotin (Gray Cap), 1 Bottle, 10 Ml: Biotinylated Monoclonal Anti Ca 19 9 Antibodies (Mouse) 3 Mg/L, Phosphate Buffer 100 Mmol/L, Ph 6.5; Preservative R2 Anti-Ca 19-9-Ab~Ru(Bpy) (Black Cap), 1 Bottle, 10 Ml: Monoclonal Anti-Ca 19-9 Antibodies (Mouse), Labeled With Ruthenium Complex 4 Mg/L; Phosphate Buffer 100 Mmol/L, Ph 6.5; Preservative Storage And Transportation Conditions: Store In The Refrigerator Strictly In An Upright Position. Shelf Life At 2 8 °C See Expiry Date On Cobas C Kit Label. When Used On Board The Analyzer At 10 - 15 °C 8 Weeks. Transportation Must Be In Thermal Containers With Cold Elements At A Temperature Of 2-8 °C Strictly In A Vertical Position, Not Subjected To Freezing Or Exposure To High Temperatures. Calibration Is Linear At Two Points, Calibration Frequency Is 7 Days. Measuring Range 0.600 - 1000 U/Ml (Determined By The Value Of The Lower Limit Of Detection And The Maximum Value Of The Master Calibration). Values Below The Detection Limit Are Displayed As <0.600 U/Ml. Values Above The Measurement Range Are Displayed As > 1000 U/Ml (Or Up To 10,000 U/Ml For 10-Fold Diluted Samples). Test Reproducibility Is No More Than 1.9%. The Supplier Is Required To Provide A Certificate Of Origin Of The Goods. Delivery Area: For Eu Countries. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification., Carcinoembryonic Antigen (Cea) Cassette For 100 Tests. (According To Technical Specification), Cassette Prostate-Specific Antigen For 100 Tests, Free (Free Psa). (According To Technical Specification), Prostate-Specific Antigen Cassette For 100 Tests Total (Total Psa) (According To Technical Specification), Prolactin Cassette For 100 Tests (According To Technical Specifications), Multiassay Diluent Multiassay, 2 X 16 Ml. (According To Technical Specification), Cassette Growth Hormone Hgh (Human Growth Hormone) For 100 Tests (According To Technical Specifications), Testosterone Cassette For 100 Tests. Reagents For The Cobas E 411 Analyzer. Testosterone Cassette For 100 Tests. Purpose: Designed For Quantitative Determination Of Testosterone In Human Serum And Plasma. Reagents And Working Solutions: The Testo Ii Label Is Affixed To The Reagent Packaging. M Streptavidin-Coated Microparticles (Transparent Cap), 1 Bottle, 6.5 Ml: Streptavidin-Coated Microparticles, 0.72 Mg/Ml; Preservative R1 Anti-Testosterone-Ag~Biotin (Gray Cap), 1 Bottle, 10 Ml: Biotinylated Monoclonal Anti-Testosterone Antibody (Sheep) 40 Ng/Ml; Release Reagent 2-Bromoestradiol; Mes Buffer 50 Mmol/L, Ph 6.0; Preservative R2 Testosterone-Peptide~Ru(Bpy) (Black Cap), 1 Bottle, 9 Ml: Testosterone Derivative Labeled With Ruthenium Complex 1.5 Ng/Ml; Mes Buffer 50 Mmol/L, Ph 6.0; Preservative Storage Conditions: Unopened At 2-8 °C Until The End Of The Shelf Life. The Supplier Is Required To Provide A Certificate Of Origin Of The Goods. Delivery Area: For Eu Countries. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification., Sys Wash Solution, 1 X 500 Ml. Reagents For The Cobas E 411 Analyzer. Purpose: System Reagent To Prevent The Formation Of Microorganisms In Water. Reagents-Working Solutions: 2-Methyl-2H-Isothiazol-3-One. The Solution Is Ready For Use. Store At 15-25 °C. Stability: Unopened At 15‑25 °C: Until The End Of The Shelf Life Upon Delivery, Present A Certificate Of Origin Of The Goods And A Power Of Attorney From The Manufacturer To Sell The Goods In The Territory Of The Republic Of Kazakhstan. Reagents For The Cobas E411 Analyzer. Delivery Area: For Eu Countries. Remaining Shelf Life Of At Least 60%. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification., Tacrolimus Immunotest Cassette For Quantitative Determination Of Tacrolimus (Tacrolimus) For 100 Tests (According To Technical Specifications), Follicle-Stimulating Hormone Cassette For 100 Fsh (Follicle-Stimulating Hormone) Tests (According To Technical Specifications), Vitamin D Cassette (Vitamin D Total) For 100 Tests (According To Technical Specifications)
|