Tender for Rate Contract Of Supply Of Different Materials For Upkeep And Maintenance Of Distribution System For The Year 2026-27 , Supply Of : , 11 Kv Link Set (Station Type) Suitable For 800 annual periodical maintenance Current Capacity. (Is: 9920 (Part-I To Iv)) With 8 Mm Copper Knife , 11 Kv Link Set (Line Type) Heavy Duty. Suitable For 800 annual periodical maintenance Current Capacity. (Is: 9920 (Part-I To Iv)) With 8 Mm Copper Knife , 11 Kv Air Break Switch With Pipe & Handle Complete (3 Phase, 600 Amp) (Is: 9920 (Part-I To Iv)) , 11 Kv Drop Out Fuse Set 3 Phase 400A (Is:9385 (Part-I To Iii) As Amended Upto Date) , Gapless Surge Arrestor, 9 Kv, 10 Kv, La With (Polymer/Porcelain) Housing, Stn. Type (Is: 3070 Part-3) , 11 Kv Pin Insulator With Pins 12 Kn. (Is:731 And Is:3188) , Lt Shackle Insulators With Mukki Clamps (16 Kn) Of Standard Make With Nuts And Bolts , Galvanised Nuts And Bolts Of Sizes. 6,7,8,9,11,12X1/2 Dia Half Thread. , G.I Wire 8 Swg. , Guy Wire 7/14 Swg. , Guy Rods With Turn Buckle 5 Long Complete , 11 Kv Tension Disc/Suspension Disc (Is:731 And Is:3188) , Fabricated Gi Channel, X-Arms Of Sizes (75X40x6) Mm (50X50x6)Mm And (100X50x6) Mm. , Fabricated Gi Angle, (50X50x6mm) , Al. Solderless Clamps Suitable For Transformer1000 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer630 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer400/500 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer250 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer100 Kva As Per Relevant Is , Al. Solderless Clamps Suitable For Transformer63 Kva As Per Relevant Is , Aluminium Thimbles 1 Mva As Per Relevant Is , Aluminium Thimbles 630 Mm2 As Per Relevant Is , Aluminium Thimbles 500 Mm2 As Per Relevant Is , Aluminium Thimbles 400 Mm2 As Per Relevant Is , Aluminium Thimbles 300 Mm2 As Per Relevant Is , Aluminium Thimbles 240 Mm2 As Per Relevant Is , Aluminium Thimbles 185 Mm2 As Per Relevant Is , Aluminium Thimbles 120 Mm2 As Per Relevant Is , Aluminium Thimbles 95 Mm2 As Per Relevant Is , Aluminium Thimbles 70 Mm2 As Per Relevant Is , Aluminium Thimbles 35 Mm2 As Per Relevant Is , Aluminium Thimbles 25 Mm2 As Per Relevant Is , Aluminium Thimbles 16 Mm2 As Per Relevant Is , 35 Mm Sq, 11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 70 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 95 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 120 Mm Sq,11 Kv Aerial Bunched Cable 3 Core + Earth , Xlpe As Per (Is 7098 Part 2 Ammneded Upto Date) Polycab/Havells/Paramount/Gloster , 16 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 25 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 185 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 240 Mm2 Single Phase Cable 1.1 Kv Grade, Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 300 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 400 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 630 Mm2 Single Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 25 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 35 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 50 Mm2 3.5 Core Armoured Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 185 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 240 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 300 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 400 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , 630 Mm2 3.5 Core Cable 1.1 Kv Grade,Xlpe Insulated Stranded Conductor Frls Type (Is 7098 Ammended Upto Date) Polycab/Havells/Paramount/Gloster , Galvanized Earthing Strips 50Mm X3mm. , Bobin Insulators Clamps/Cliffs. , Back Clamp Collars/Pole Collars G.I. , Galvanized Abc Cable Hooks/I Hooks , Aluminum Paint (Asian/Nerolac/Berger) Make. , Red Oxide Paint (Asian/Nerolac/Berger) Make. , 11 Kv Heat Shrinkable Outdoor Cable Termination Kit Of Sizes , 11 Kv Heat Shrinkable Outdoor Cable Jointing Kit Of Sizes , 300 Mm Sq 11 Kv Heat Shrinkable Cable Jointing Kit , 11 Mtr. (Is 2713 540 Sp 56)Steel Tubular Poles , 9 Mtr. (Is 2713 540 Sp 33)Steel Tubular Poles , 8 Mtr. (Is 2713 540 Sp 15)Steel Tubular Poles , 30Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 50Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 100Mm2 Acsr Conductor Is: 398(Part-Ii) Ammended Upto Date , 630 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 400 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 200 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 160 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 100 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , 63 annual periodical maintenance 3 Pole Thermal Magnetic Mccbs Having Adjustable Thermal (0.8 In-1.0 In) . With Fixed Magnetic Setting Of 10*In, Breaking Capacity Not Less Than 50Ka (Ics=Icu=100%), With Spreader Links, Phase Barriers, & Direct Mounting Rotary Operating Mechanism(Rom). The Rom Shall Be Lockable In Off Position. The Mccb Should Be Ce Marked And Shall Conform To Iec:60947-2-2003 Standards. The Mccb Shall Have A Maximum Operational Voltage (Ue) 690V, Insulation Voltage (Ui) 1000V, And Impulse Withstand Voltage (Uimp) 8Kv. Mccbs Shall Be Actuated By A Rotary-Handle That Clearly Indicates The Three Distinctive Positions: On, Off And Tripped, Total Opening Time 10Msec, Mechanical Life 25000 Operations & Electrical Life @415V Ac 10000 Operations. (Make: Abb/Eaton/Havells/Legrand/L&T/Schneider/Siemens) , Rubber Shoes Sole Insulation Is 4770 Ammended Upto Date And Working Potential Of 11 Kv , 20 Feet Long , 11 Kv Discharge Rod Set ( Each Set Containing 3 No Rods), Copper Electrode , Manufactured From Fibre Reinforced Plastic Material , Having Hv Test Of 110 Kv, Push Button Locking Sytem, Crocodile Grounding Clamp , Rubber Clading To Hold, Die Cast Alu. Earthing Instrument For 30Mm Diameter (With 4 Sq Mm Copper Cable 8 Mtrs; Top Section Diameter 25 Mm And Bottom Section Diameter 45 Mm) With Earthing Spike Of Standard Make , Battery Operated 11-33 Kv Voltage Detector (Cpri Tested) Complete Kit Including Hv Detector Probe, 20 Feet Frp Insulation Stick, Carrying Bag. The Detector Should Have Audio As Well As Visual Anunciation, Sensing Distance Of 1 Meter For 11Kv And 3 Meters For 33Kv. Bright High Intensity Red Leds For Visual Annunciation Even In Unfavourable Daylight Conditions And A Buzzer To Produce Loud Beep Audible Even In Noisy Backgrounds , Natural Latex 11Kv Rubber Gloves (Type-2 Is 4770; Isi Mark) With Test Voltage =17000 V And Working Voltage Of 11000 With Maximum Leakage Current At Tets Voltage Of 14Ma (Rms) [ Isi Mark And Is Conformation On Each Glove] , White Color Industrial Safety Helmets (Is 2925) With Chin-Strap And Nape-Strap With Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance As Per Is 2925 [ Isi Mark And Is Conformation On Each Helmet] , Yellow Color Industrial Safety Helmets (Is 2925) With Chin-Strap And Nape-Strap With Flammability Resistance, Electrical Resistance, Water Absorption, Heat Resistance As Per Is 2925 [ Isi Mark And Is Conformation On Each Helmet] , Safety Belt With Static And Dynamic Loading Completely As Per Is 3521 [ Isi Mark And Is Conformation On Each Belt] , Uk Size 6 And Below Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 7 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 8 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 9 Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Uk Size 10 And Above Safety Shoe For 11-33Kv Working Environment Completely As Per Is 15298 Iso 20344 [ Isi Mark And Is Conformation On Each Shoe] , Complete Tool Kit ( Screw Driver -4 No, Plier-1 No, Spanner (6 To 36)-1 Set, Wrench 12-1 No, Measuring Tape 25 Mtr-1 No, Hexa Frame With Blade-1 No, Tester-1 No, L Key -1 Set And Combination Spanner (6 To 36)-1 Set Bosch/Dewalt/Taparia , Clamp Meter, Conforms To Iec 61010, Cat Ii 600V Safety Rated, 600A Ac Current Measurement, Ac/Dc Voltage, Resistance, Continuity & Data Hold Function, 2 Years Manufacturer Warranty [Fluke/Digi Sense/ Motwane/Extech] , 18 Feet Fiber Link Rod , 18 Feet Bamboo Link Rod , Manually Operated Megger (500/1000 Mega Oms) , Lt Fuse Set (630 Amp) 11 Kv Polymer Type , Gi Chemical Earthing 2 Mtr With Chemical Bag , Search Light (Led) 1 Km Range , Bamboo Ladder 18 Long , Aluminium Folding Ladder 20 Ft Long , Wooden Ladder A Class Budloo [Finished Length Of 17 (3 By 1.5) ; Finished Step (2 By 1.5 ) ; Bottom Width 18; Step To Step Distance 13] Alongwith Ms Straps On Both Side Of Each Step , 16 Mm² Cable (2C) From Lt Line To Meter ,1.1K V Grade, Armoured, Pvc Insulated Stranded Conductor Frls Type (Is 1554 Part 1 Ammended Upto Date) Polycab/Havells/Paramount/Or Equivalent , Single Phase Smd Box With Bus Bar (8 Way) , Three Phase Smd Box With Bus Bar (12 Way) , Anti Climbing Devices With Clamps , Sl Clamp , Lt Shackles With D Clamp , Suspension/ Tension Clamps With Eye Hook , Danger Plate , Pole Butt , Eye Bolt , 35 Mm² Ab (Lt) Cable ( 3 X 35 + 1 X 16 + 1 X 25 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , 50 Mm² Ab (Lt) Cable ( 3 X 50 + 1 X 16 + 1 X 35 Insulated)Mm² Xlpe (1.1Kv, 3+1 C, Al) , 70 Mm² Ab (Lt) Cable ( 3 X 70 + 1 X 16 + 1 X 50 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , 120 Mm² Ab (Lt) Cable ( 3 X 120 + 1 X 25 + 1 X 95 Insulated) Mm² Xlpe (1.1Kv, 3+1 C, Al) , Smdbs Single Phase , Smdbs Three Phase , Hoose Pipe 1.5 , 300 Mm Sq Ab Ht Cable Single Core , 45 Watt Led Luminary Energy Saving & Enviromentally Friendly Long Life Led Street Light Almunium Die-Cast Housing (Ip 66 Protection Sun-Beam Seno) Certified By Bis,Roh,Ce With Two Years Warrenty After Date Of Commissioning , 70 Watt Led Luminary Energy Saving & Enviromentally Friendly Long Life Led Street Light Almunium Die-Cast Housing (Ip 66 Protection Sun-Beam Seno) Certified By Bis,Roh,Ce With Two Years Warrenty After Date Of Commissioning , 3/4 Pvc Pipe For Service Line Fixing On Pole With Ties Belt , 200 Watt Led Flood Light/Luminaries Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 150 Wattled Flood Light Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 110 Watt Led Light Ip 66 Cerified With Bis, Roh Ce & Company Scaner Bar-Code , 130 Watt Led Light /Luminaries Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , 90 Watt Led Lights / Luminaries Flood Light Ip 66 With Bis, Roh Ce & Company Scaner Bar-Code , Led Drivers For 200 Watt Led Lights , Led Driver 130 Watt Led Light Of Standar Make Pasted With Company Scaner Code , Led Driver For 120 Watt Led Lights Pasted With Company Scaner Code , Led Driver 110 Watt Led Light Pasted With Company Scaner Code , Led Driver For 80 Watt Led Light Pasted With Company Scaner Code , 19 Mm Dia Pvc /Hdpe Conduit , 25 Mm Dia Triple Lyer Hdpe Conduit , 50 Mm Dia Triple Lyer Hdpe Conduit , 70 Mm Sq Tripl Layer Hdpe Conduit , 1.5 Mm Sq Copper Wire , 2.5 Mm Sq Copper Wire , 4 Mm Sq Copper Wire , 6 Mm Sq Copper Wire , 2 Amper Single Pole Mcb , 6-10 Ampere Single Pole Mcb With Box , 16 Ampere Double Pole Mcb , 25 Ampere Mcb 04 Pole , 32 Ampere Single Pole , 32 Amper Double , 32 Ampere Tpn 04 Pole Mcb , 40 Ampere Tpn 04 Pole Mcb , 63 Amper 4 Pole Mcb , 100 Ampere Mccb Of Standar Make , Led Bulb 09/11Watt Of Standard Make Certified Isi Make , Led Bulb 50/45 Watt Of Standard Isi Certified Make , Time Delay Relay For Servo Stabilizer , Astrnomical Timer Of Standard Make , 50 Hz Contractor Of Standard Make , Distilled Water , Ms Nuts, Bolts , Washers Of Sizes , 11 Kva Cable Joint Kit , 11 Kva Cable Termination Kit , 10-95 Sq Mm Al, Thimbles , Cable Jointing Thimble 10-95 Sq Mm , 6 Sq Mm 02 Coreal, Cable Standard Make , 10 Sq Mm 02 Core Al Cable , 16 Sq Mm 02 Core Cable , 25 Sq 02 Core Al Cable , 6 Sq Mm 04 Core Al Xlpe Cable Of Standar Make , 10 Sq Mm 04 Core Al Xlpe Cable , 16 Sq M 3.5 Core Xlpe Cable , 25 Sq 3.5 Core Xlpe Cable , 35 Sq Mm 3.5 Core Cable , Pvc Tape Roll , 8 Inche Taparia Plair , Star Type Screw Driver Big Size , Star Type Screw Driver Medium Size , High Beam Torch Light , Tool Box , 100 Amper Bus-Bar 1 18 To 24 Copper , 100 Amper Bus-Bar 1 18 To 24 Aluminum , 08 Way Termination Blocks / Connector , 150 Watt Led Driver 700 Amper Constant Current Philpps, Havells, Fulham Certified With Bis, Roh , Ce With Company Bar-Code Scanner , 130Watt Led Ornamental Hanging Type Luminary Housing (Dgl-103-M) D Fitted With 130 Watt Led Panel For 9Mtr Longt Iron/Ms Composite Pole. , Batton Type Brass Holder , Pendent Holder , Ms Junction Box Complete With Fixed Clamps Nuts And Bolts , Abs Transpernt Junction Boxs , Time-Delay Rellay , Repairs Of 10Kva To 25 Kva Avr , Transformer Oil , M.S Boss Fitted For 100 Ampere Mccb Complete , Earthing Spike- Rod 2 Mtr Long , 08 No.G.I Wire , 80 To 120 Sq Mm Al, Thimble , 11 Kv Link-Set , 11 Kv Drop-Out Set , 11 Kv Surge Lighting Arrestor , Extension Cords Heavy Duty , 250X500 Mm Pcd G.I Door Plate For 9/7 Mtr Long Octogonal Pole , Piercing Connectors Of Sizes
|