|
Tender For Major Works At Girls Ashram Hostel Merpur Kotda Udaipur- 1 Dismantling Doors, Windows And Clearatory Windws Steel Or Wood Shutter Including Chowkhats And Holdfasts Etc. 2 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meter Lead: For Thickness Of Tiles 10Mm To 25Mm. 3 Dismantling Gi Pipes (External Work) Including Excavation And Refilling Trenches After Taking Out The Pipes And Including Stacking Of Pipes Within 50 Meter Lead: 4 Dismantling Old Plaster Or Skirting, Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Meter Lead. 5 Grading Roof For Water Proofing Treatment With Water Proffing Compound. Cement Mortar 1:4 (1Cement : 4 Coarse Sand) 6 Providing & Laying Broken Glazed Titles On Roof ( Broken Glazed Tiles Not Less Than 9 Kg/Sqm) On Top Of Hot Bitumen @ 1.7 Kg/Sqm. (1.40 Kg Of Vg-40 (30/40 )Grade And 0.30 Kg/Sqm. Of Vg-10 (80/100) Grade) And Joints Filled With Cement Mortar 1 :2 (1 Cement:2 Marble Dust Mixed With Water Proofing Compund All Complete As Per Direction Of Engineer-In-Charge. 7 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead With Cement Mortar 1 :4 ( 1 Cement : 4 Coarse Sand) 8 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1Cement : 3-Fine Sand) 9 Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete.New Plastered Surface (Three Or More Coats) 10 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). 11 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.Cm 12 Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (Average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete 13 Providing And Fixing Of Double Leaf Steel Shutter For Cupboard, The Sqm Frame Is Made Of Pressed Steel Isi Section 80X25 Mmx 1.25 Mm Thick With 1.00 Mm Ms Sheet To Spot Welded Including Holdfasts Of 15X3Mm, Ms Oxidized Fittings Such As Butt Hinges, Sliding Doors Bolts, Handles, Tower Bolts And Twin Peg Etc Complete Including Applying Priming Coat Of Approved Steel Primer Of Red Oxide Zinc Chromate And Spray Painting In Approved Shade With Deco Paint Of Approved Quality Complete As Per Direction Of Engineer In Charge 14 Providing And Fixing In Position Collapsible Steel Shutters With Vertical M.S. Channels 20 X 10 X 2Mm And Bracket With Flat Iron Diagonals 20 X 5Mm. Size With Top And Bottom Rail Of T-Iron 40 X 40 X 6Mm. With 40Mm Dia Steel Pulleys/Ball Bearing Complete With Bolts, Nuts Locking Arrangements Inside And Outside Stoppers, Handles Etc. As Per Specification Including Applying A Priming Coat Of Approved Steel Primer. (To Be Measured And Paid As Per Outer Dimension). 15 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10Cm Long Embedded In Cement Concrete Blocks 15X10X10 Cm Of 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Require Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 16 Providing And Fixing M.S. Sheet 1Mm Thick Dabble Leaf Door Shutter In Angle Iron Frame 35X35X5Mm Suitabilly Diagonally Braced With 25X3Mm Flat Iron Above And Below Lock Rail Of Size 50X5Mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-Corrosive Red Oxide Primer Paint Add Extra For Double Leaf Shutters. 17 Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3Mm With Suitable Screw At Not Exceeding 150Mm Distance. 18 Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. 19 Repair Of Door, Window Shutters Including Cost Of Material And Labour For Change Of Damaged : Aldrop Of Mild Steel 12\ Long X12Mm Dia 20 Steel Hinges For Wooden Chowkhat 4\ Size. 21 Steel Handle 6\ Size 22 Labour Charges For Repair To Door / Window Without Using Any Material Such As Applying Randha (Finishing) Tightening Of Bolts & Screw Etc. 23 Providing And Fixing Steel Gate, Grating , And Grills Made Of Angles, Tees, Square Bars, Flats,Or Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide Extra If Square,Rectangular Hollow Tubelar Sections Are Used Or Grill Made By Flats Only 24 Providing & Fixing Uv Stabilised Fiberglass Reinforced Plastic Sheet Roofing Upto Any Pitch Including Fixing With Polymer Coated „J? Or „L? Hooks, Bolts & Nuts 8Mm Dia. G.I Plain/Bitumen Washers Complete But Excluding The Cost Of Purlins, Rafters, Trusses Etc. The Sheets Shall Be Manufactured Out Of 2400 Tex Panel Rovigs Incorporating Minimum 0.3% Ultra-Voilet Stabiliser In Resin System Under Approximately 2400 Psi And Hot Cured. They Shall Be Of Uniform Pigmentation And Thickness Without Air Pockets And Shall Confoim To Is 10192 And Is 12866.The Sheets Shall Be Opaque Or Translucent, Clear Or Pigmented, Textured Or Smooth As Specified. 3.0Mm Thick (Wt. 5.0 Kg./Mtr. Sq.) 25 Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding: 26 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). 27 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work 28 Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture : 29 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 (Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 30 Providing And Laying Ceramic Mat Floor Tiles (Thickness To Be Specified By The Manufacturer) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown Of Any Size, Laid On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 31 P & F Indian Type White Glazed Vitreous China 1St Quality W.C. Orissa Pan (Is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 580X440Mm. 32 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/C Fixing The Pipe With Clamps At 1 Metre Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. (Internal Work Exposed On Wall) 15 Mm Nominal Size 33 20Mm Nominal Size 34 Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes (Is 15778 : 2007 Code) Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings, This Included Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement , Trenching Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.(External Work).15 Mm Nominal Size 35 20Mm Nominal Size 36 P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 75 Mm Dia 37 P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia 38 P&F Rigid Pvc Pipe (Is:4985 Mark) Class Ii/ (4 Kg. /Cm2.) Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 160 Mm Dia 39 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Coupler (Socket) 160 Mm Dia 40 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Plain Tee 160 Mm Dia 41 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Door Tee 110Mm Dia. 42 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 45. 110Mm Dia. 43 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 45. 160Mm Dia. 44 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 87.5. 110Mm Dia. 45 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Bend 87.5. 160 Mm Dia. 46 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Door Bend (Top Side) 110Mm Dia. 47 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Pipe Clip 110Mm Dia. 48 P&F Rigid Pvc Pipe Fittings (Is: 4985 Mark) Of Approved Quality /Make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. Pipe Clip 160Mm Dia. 49 P & F Pvc Storage Tank Isi Marked (Is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25Mm Dia 1M Long G.I. Over-Flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design. 1000 Litres Capacity. 50 P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make. Gun-Metal 15Mm Nominal Bore. 51 P & F Full-Way Valve (Is:778 Mark) Or Wheel Valve Of Approved Make. Gun-Metal 25Mm Nominal Bore. 52 Construction Of Septic Tank In All Types Of Soil With 40 Cm .Thick Masonry In Cm 1:6, 15 Cm Thick C.C Bed Of 1:5:10, M-15 Grade C.C Floor & Rcc Slab Covering With M15 Grade C.C. Floor, 50 Mm Thick Stone Slab Partition Walls, 20 Mm Thick Plaster In Cm 1:6 Finished With Neat Floating Cement, 4 Nos Stone Foot Rests Of Approved Design ,Two No. 450 Mm Dia Each Ferro Cement Cover With Frame, Earth Work Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr:- Size 400 X140X150 Cm.(For 50 Users) With 115 Mm Thick Rcc (M-20) Slab With Tor Steel Reinforcement 10Mm F @15 Cm C/C Bothways Including Shuttering Complete In All Respect 53 Size 230 X110 X150 Cm.(For 20 Users) With 115 Mm Thick Rcc (M-20) Slab With Tor Steel Reinforcement 10Mm F @15 Cm C/C Bothways Including Shuttering Complete In All Respect. 54 P & F Wvc Wash Basin (Ist Quality Is:2556 Mark) Of Approved Make With C.I. Brackets Duly Painted 1 No. 15 Mm C.P. Pillar Cock (Is:8934 Mark) & 32 Mm C.P. Brass Waste Coupling Of Approved Make, P.V.C Waste Pipe With Pvc Nut 32 Mm Complete Including Cutting & Making Good The Wall :Size 550 Mm X 400 Mm 55 P & F Looking Mirrors With P.V.C. Frame Of Approved Make As Per Direction Of Engineer-In-Charge Size 500X400Mm 56 P & F Grating Of Approved Quality/Make:Stainless Steel Sheet Size 125Mm Dia. 57 P & F Bib Cock (Is : 8931 Mark), Superior Quality Of Approved Make: Brass 400 Gm,15Mm Nominal Bore. 58 Construction Of Manhole In All Type Of Soil Inner Size 90 X 60 Cm. 300 Mm Thick Masonry In Cm 1:6, 10 Cm. Thick Cement Concrete 1:5:10 In Foundation, 20 Mm Thick Inside Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade C.C. Flooring, Making Channels, 80Mm Thick Stone Slab Covering With 40Mm Thick M-15 Grade C.C. Flooring, Cement Cover With Frame Of 450Mm Dia, Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within 50 Mtr. Lead.Depth Up To 0.5 M 59 Construction Of Chamber In All Type Of Soil With 300 Mm Thick Masonry In Cm 1:6 M,10 Cm Thick C.C. 1:5:10 In Foundation, 20Mm Thick Insider Plaster In Cm 1:6, Finished With Floating Neat Cement, 50Mm Thick M-15 Grade C.C. Flooring , Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr.-Do- Size 450 X 450Mm Depth Upto 0.5 M Cement Cover With Frame 60 Construction Of Soakage Well In All Type Of Soil With 300 Mm Thick Dry Masonry, Top And Bottom 300 Mm Course In Cm 1:6, 80Mm Thick Stone Slab, Jointing Of Slab In Cm 1 : 3, Ralthal, Kharanja, 40 Mm Thick M-15 Grade C.C Flooring , Earthwork Complete As Per Approved Drawing Including Disposal Of Earth Within A Lead Of 50 Mtr.: Size 300 Cm. Dia Outside & 300 Cm. Depth . 61 P & F Flush Cock / Flush Valve (Is : 9758 Mark) For Wc Of Approved Quality Make : (-Do-) Half-Turn Exposed 25Mm Nominal Bore. 62 P& F Waste Coulping With Fittings Of Approved Quality /Make: C.P Brass 32 Mm Dia 63 P& F Waste Pipe With All Fitting G.I(B Class) 32Mm 64 Construction Of Open Drain With 112Mm Thick Brick Masonry In Cm 1:4 Semi Circular S.W. Glazed Channel (Confirming To Is Standards) Fixed With Cement Mortar 1:1 Over A Bed Of 100Mm Thick C.C. 1:5:10, Filling Of Edged With M-15 Grade C.C. Flooring, 12Mm Cement Plaster 1:4, Over All Exposed Faces, Excavation & Disposal Of Earth With In A Lead Of 50 Mtr Complete As Per Approved Drawings : 150 Mm Drain,225Mm Av. Depth Width 15 Cm S.W. Glazed Channel. 65 Construction Of Tube-Well Upto 100 Meter Depth And Above In All Type Of Rocks By Dth System And Over Burden, To Accommodate Casing Pipe Of Following Sizes In All Types Of Soils And Over Burden Including Lowering Of Casing Pipes, But Excluding Cost Of Casing Pipes As Per Is : 2800 (Part I & Ii) 1979 Specifications. The Work Would Be Completed After Obtaining Sand Free Water. The Tube Well Should Have A Throughout Bore As Per Nominal Dia Of Casing Pipe: 150Mm 66 Supply Of Erw M.S. Black Casing Pipe Isi Marked (Is:4270/1992) Of Grade Fe410 Of Following Sizes At Site Of Work. 150 Mm Nominal Bore Of Pipe 67 S & F Tube Well Cover Of M.S.Sheet (6Mm Thick) With Nuts And Bolts Complete For Casing Size: 150Mm Dia 68 S & F M.S. Clamp, Set Of 50 ×6Mm Flat Iron With Nuts And Bolts Etc. For Holding The Riser Pipe Assembly Of Submersible Pump Set. 69 Providing & Fixing Of Hdpe Pipe Confirming To Is:4984:2021 For Water Supply Suitable For Submersible & Jet Pump With Required Fittings Ie Socket, Elbows, Tee Etc. Complete In All Respect. For Vertical Installation 63 Mm Od 6 Kg / Cm2 70 For Horizontal Installation 63 Mm Od 4 Kg/ Cm2 71 Sitc Of Radial / Mixed Flow Water And Anti-Corrosive Liquid Filled Submersible Motor Pump Sets Suitable For 100/150Mm Dia Borewell. The Size Of Adopter Fixed On Top Of The Motor Should Exceed The Top Of Coupler , For Safegaurd The Coupler. The Job Includes Labour Part Of Lowering Of Riser Pipe G.I./ H.D.P.E. With Rope, Cables & Pump, Installation Of Complete Fitting And Accessories, Jointing Of Electrical Cables Up To Starter. All Labour For Testing Of Submersible Pumps Set And Supply Of Water To Water Mains, Complete In All Respect. 100 Mm Diameter Submersible Pump Shall Have Following Hp Rating, Phase, Head Range, Discharge Range Respectively. 3.0 Hp, 1-Ø, (40 -170)Mtr, (60- 20) Lpm Copper Wound 72 Sitc Of Ip 54 Oem Fabricated Dol/Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Coordination Chart And Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection(For Three Phase Pumps), Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps, 2P/4P Mcb Etc. Suitable For Following Rating Motors Complete In All Respect. For Three Phase Submersible / Mono Block Pump 3.0 Hp To 5.0 Hp ( Dol Starter ) 73 Providing & Laying Of Polypropylene Rope Confirming To Is:5175 For Submersible Pump Of Following Sizes. Complete In All Respect. 20Mm (Suitable For 90 Mm Od Pipe) 74 Supply And Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To(Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From Copper, Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. 10.0 Sq.Mm 3 Core Flat / Round 75 Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & ItS Isi Marked (Is:3419-1988) Accessories, Round Tiles, 1.2 Mm Thick Hot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Short Point (Up To 3 Mtr.) 76 Medium Point (Up To 6 Mtr.) 77 Long Point (Up To 10 Mtr..) 78 Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & ItS Isi Marked (Is:3419-1988)Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modular Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated SheetS & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr On Board 79 Medium Point (Up To 6 Mtr.) 80 Long Point (Up To 10 Mtr..) 81 Supplying And Fixing Of Power Plug Point With Modular Accessories As Per Pwd Specification For Electrical Works, On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal/Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Of Isi Marked Modular 16 Amp. Switch (Is :3854) And 6/16 Amp. Socket Outlet (Is:1293) Making Connection , Testing , Etc. As Required. For Specification Of Wiring Accessories Refer Chapter E - 07 Related Item & For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 82 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Blanking Plate 83 Modular Mcb 6 A To 32 A Dp (Is:8832 Marked) 84 Providing & Fixing Of Modular Type 100W Step Fan Regulator Duly Isi Marked (Is 11037) With Cm/L No. Printed Made Out Of Unbreakable And Fire Retardant Virgin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including Making Connections, Testing Etc As Required. 5 Step Fan Regulator 2 Module 85 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 1 X 1.5 Sq.Mm 86 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 87 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm 88 2 X 6.0 Sq. Mm. + 1 X 2.5 Sq. Mm 89 4 X 10.0 Sq.Mm 90 4 X 6.0 Sq.Mm 91 1 X 16.0 Sq.Mm 92 1X 4.0 Sq.Mm. 93 Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Glazed Door (Three Phase) Ik-09 And Ip-43 With Metal End Box 6 Way 94 Glazed Door (Single Phase) Ik-09 And Ip-43 With Metal End Box 12 Way (12+2) 95 Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Single Pole Mcb (With B/C Curve Tripping Characteristics) 6 A To 32 A Rating 96 Double Pole Mcb(With B/C Curve Tripping Characteristics) 40 A Rating 97 Four Pole Mcb(With B/C Curve Tripping Characteristics) 50/63 A Rating 98 S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners Etc. As Required. 32 Mm X 12 Mm 99 Making Of Hole In Wall (Brick/Stone) Of Required And Placing Np-2 Rcc Pipe Ring Of Required Size For Housing Exhaust Fan And Making Good The Same, With Cement Plaster Required Of Following Size. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . Up To 457 Mm Size 100 P & F 1.2Mm Thick M.S. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 101 Providing & Fixing Of Heavy Duty Capacitor Start, Copper Wound Double Ball Bearing 900/1400 Rpm Single Phase Exhaust Fan Conforming To Is:2312 Isi Marked In Existing Opening Including Making Connections Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 300 Mm Sweep(900/1400 Rpm) 102 P & F Of Gravity Louver Shutter Of Superior Quality Made Out Of Frame Of 18 Swg M.S. Sheet & Louvers Made From 24 Swg Ms Sheet With Enamel Paint Including Cost Of Nuts, Bolts, Etc As Required. Up To 380 Mm Size 103 Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Powder Coated Extruded Aluminium Housing With In Built Driver , System Lumen Efficacy = 110 Lm/Watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,Thd 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 1170Mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm 104 Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqaure Smd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housing With Uv Stabilized Non Yellowish Diffuser With Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency > 85% . System Lumen Efficacy Of = 110 Lm / Watt, Thd 80, Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . Surface Mounting (With Extruded Alumn. Housing ) Minimum Lumen Output 1600 Lm 105 Minimum Lumen Output 1950 Lm 106 Sitc Of Ip20, 1X1 Led Surface/ Recessed Mounting Backlit & Smd Mid Power Type Led Light Fixture Not Less Than 35 Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution.Operating Voltage Range 140-285 V, Hv Cutoff - Lv Cutoff Should Be 300-100V High Efficiency With 4 Kv Internal Surge Protection Bis Certified Isolated Driver Having Efficiency > 85% , With Short & Open Circuit Protection (Integral With Light Fixture). System Lumen Efficacy Of = 120 Lm/Watt ,Thd 80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) As Required. Surface Moutning Minimum Lumen Output 3600 Lm 107 Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (I.E. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 1200 Mm Sweep Bee 1 Star Rated (Service Value >=4.0 To 108 Providing & Fixing Of Extra Down Rod Of 15 Mm Dia . Erw (Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steel Pipe Including Cutting, Threading, Drilling, Fixing Quarter Pin Etc As Required. 109 Providing & Fixing Of 450 Mm Sweep Oscillating Type Wall Mounting / Pedestal Type Fans With Three Speed, On And Off Position, Sintered Iron Bush Oil Impregnated, With Metal Front And Back 120 Or More Ribs Guard; Three No. Aluminium Blades, Minimum Air Delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./Min/Watt, Noise Level Should Be 110 Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core 1.5 Sq.Mm Copper Conductor ,Making Connections, Testing Etc. As Required. 300 Mm Sweep 111 Supply And Installation Of High Tensile Low Carbon Steel Rod Molecularly Bonded With 99.9 % Copper Thickness (250 Microns) And Confirming To Ul 467, Is/Iec 62561-2 Of Following Size And Length And As Per Point Mentioned (A), (B), [C), (D), (E) Below :- (A) Bore A Hole Of Dia. 100 Mm Of Required Length, Place The Rod In The Centre Of Hole (B) Filled With Anti Corrosive Conductive Compounds With The Permanent Sealings At Both The Ends, Cpri/ Erda Tested With Rms Capacity Of Minimum 30 Ka For Withstanding 1 Second .To Ensure The Moisture Content And Electrical Conductivity, 25 Kg For 2000 Mm & 50 Kgs For 3000Mm Of Resistance Lowering Earth Enhancement Material Shall Be Used As A Backfill Compound. The Compound Shall Be Tested Form Nabl Acredeated Lab For Low Resistivity ( Less Than 0.12 Ohm - Meter ) & High Conductivity In Nature With Carbon As A Major Content As Per Referance Of Is 3043-1987,Ieee 80-2013 (Clause 14.5D) , Ieee 837 & Ier 1956 With Latest Amendemnts © Connect The Rod With Copper Strip/Conductor/Wire With Suitable Clamp Made From Tinned Copper And Ss 304 Bolt (D) Place Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. (D) Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book. (E) Test Certificates For Confirming Above Standards From Oem Is Mandatory. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure \A\ Attached With This Bsr . 17.2 Mm Thick And 3 Mtr. Long 112 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. 8 Swg Copper Wire 113 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket/Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminum Material With Heat Dissipation Fins On Housing With Uv Stabilized Pc (Uv Stablization Report Submitted For Uv Cover ) /Toughened Glass Cover And Secondary Lens On Each Led/ Integrated Lens Diffuser & Should Be High Power Led Of 3 To 5 Watt Each . The System Efficacy >=125 Lm/ Wt And Integrated Metal Case Potted Driver & Has A Unique Bis R Number ( As Per Is 15885) With Input Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac & Low Voltage Cutoff @>=90 V Ac And Auto Resetting Safety , Power Factor >0.95 Driver Efficiency >85% ,Thd(I) 70 And Cct 5700K +355K. Surge Protection Shall Be Min = 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs As Required. Led Street Light Fixture With Minimum Lumen Output 2500 Lm 114 Providing & Fixing Of Street Light Bracket Made Out From Following Size Of B Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. 32 Mm Dia. 115 Supply & Fixing Of Dry Powder Agent (As Per Is 4308:2019), Abc Type Fire Extinguisher (Stored Pressure Type) Conforming To Is:15683:2018 , Powder Coated Internal & External Surface Deep Drawn Cylinder Body Of Mild Steel Cr2 Grade Conforming To Is: 513, Squeeze Grip Forged Brass Release Valve With Inbuilt Safety Release Device, Diaphragm Type, 0 To 28 Bar Range Pressure Gauge, 450 Mm Long Epdm Discharge Tube, Qr Code For Product Traceability Including Fixing On Wall With Suitable Anchor Fasteners As Required Of Following Capacity. Test Certificates Of All The Parameters Along With Hydro Test & Burst Test (For Cylinder Body) Certificate From Oem / External Nabl Accrediated Lab Is To Be Submitted. 6 Kg 116 Sitc Of Ro Water System With Filteration Stages = Particilate Filter- Membrane Life Enhancer Filter- Sediment Filter- Pre Carbon Filter- Ro Membrane Filter- Post Carbon Filter. Input Power Rating -230V Ac, 50Hz, Percentage Of Rejection Tds-90% Or Better, Having Following Features (A) Double Purification By Ro With Ess Or Latest Technology With Tds Indicator. (B) Spin Welded Ro Membrane Housing To Prevent Tempering. (C) Push Fit Component For Leak Proof Performance. (D) Fully Automatic Operation With Auto Start And Auto Off. (E) Ss/Abs Construction For Corrosion Free Lifespan. (F) Equally Suitable For Water From All Borewells, Overhead Storage Tanks, Water Tankers And Even Municipal Taps. (G) Ro Membrane Flushing - Auto Flush@ Every Start, Every Stop And Every One Hour Of Working For One Minute, Complete In All Respect With Following Capacity. Purification Capacity - 50Lph, Duty Cycle 270-500 Liters/Day 117 Supply , Installation, Testing And Comissioning Of Is:1475 Marked Self Contained Drinking Water Cooler With Hermetically Sealed Compressor,Non Cfc Refrigerent Suitable For Operation On 230V/1Ph/50Hz Ac Supply,Full Stainless Steel (Ss304)Body (0.8 Mm Thick) And Tank (0.5 Mm Thick) , Stainless Steel Water Tray,Minimum Two Nos Brass Chrome Plated Faucets And Suitable Drainage System Complete In All Respect With Required Height Ms Fabricated And Painted Angle Iron Frame ( Cost Of Frame To Be Paid Extra )Complete In All Respect Of The Following Capacity. Cooling Capacity 150 Ltr./Hr. And Storage Capacity 150 Ltrs 118 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means Over Areas (Exceeding 30Cm In Depth. 1.5M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Upto 50M And Lift Upto 1.5 M , Disposed Earth To Be Levelled And Neatly Dressed : All Kinds Of Soil 119 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). 120 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size). 121 Kerb Stones Of 1200X300X150, 1000X450X150, 1000X600X150, 600X300X150 Size (M-30) Providing And Laying Cement Concrete Kerb Stones Of Different Sizes In M-30 Grade (Manufactured With Fully Mechanised Dry Cast Process With Forced Action Mixer Whose Arms Revolve Along The Main Axis And Rotate About Its Own Axis Also, Having Humidity Sensor For Moisture Control Of W/C Ratio In Concrete Mix. Manufactured With Steel Moulds (Milled And Manufactured In Csi Diamond Or Csi Nitro Process For Accuracy) On Steel Base Plate Of Min 16 Mm Thick; Having Vibration And Pressing Action Both Together With The Help Of Multiple Synchronised Vibrators. Power Of Hydraulic Station Should Be Minimum 50Kw For Compaction And Cured In Controlled Chambers Having Humidity Control And Automated Air Circulation System) In Position To The Required Line, Level And Curvature Jointed With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Including Making Of Joints, Drainage Opening Wherever Required. 122 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means Over Areas (Exceeding 30Cm In Depth. 1.5M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Upto 50M And Lift Upto 1.5 M , Disposed Earth To Be Levelled And Neatly Dressed : All Kinds Of Soil 123 Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). 124 Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 125 Providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix 126 Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.M20 Grade Nominal Mix / Design Mix 127 Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. 128 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Columns, Pillars, Posts And Struts Etc. 129 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (Including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-Mechanically Treated Bars (Conforming Of Relevent Is Code) 130 Random Rubble Stone Masonry With Hard Stone In Superstructure Above Plinth Level And Upto Five Level Above 30Cm. Thick Walls In : Cement Mortar 1:6 ( 1-Cement : 6-Sand). 131 Plaster On New Surface On Walls In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish : 25 Mm Thick. 132 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). 133 Providing And Fixing Steel Gate, Grating , And Grills Made Of Angles, Tees, Square Bars, Flats,Or Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide Extra If Square,Rectangular Hollow Tubelar Sections Are Used Or Grill Made By Flats Only 134 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work 135 Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size).
|