|
Tender for Running Maintenanc & Operation Of Fire Fighting System,Fire Alarm System & Pa System And Cctv System, Epabx System & Iei At Community Hall In Different Pockets I.E A,B-1,B-2,C & D & Dda Project Office (Loknayakpuram ) Bakkarwala As Per Inventory Attached. I) Wireman-1 No. 52 Days (Once In A Week And Whenever Is Required) Ii) Khallasi - 1 No. 52 Days (Once In A Week And Whenever Is Required). , Running Maintenance & Operation Of Sewage Pump Sets And Cctv System At Sewage Pump House As Per Inventory,Terms And Conditions Attached. I) Wireman-1 No. 52 Days (Once In A Week And Whenever Is Required) Ii) Khallasi - 1 No. 52 Days (Once In A Week And Whenever Is Required). Iii) Pump Operator Gr-Ii- 2 Nos. ( 6:00 Am To 2:00 Pm And 2:00 Pm To 10:00 Pm And Whenever Is Required) , Running,Operation & Maintenance Of Existing Street Lights On Upto 12 Mtr Height Poles Complete With Feeder Pillers,Switchgears,Pole Boxes, Copper Wires & Distribution Cables Etc In Various Locations As Per Inventory With Tower And Wagon Whenever Required . I) Wireman -1 No. 104 Days (Twice In A Week And Whenever Is Required) Ii) Khallasi - 1 No. 104 Days (Twice In A Week And Whenever Is Required). , Repairing Of 40 Hp Sewage Pump Set I/C Supply & Replacement Of Following Worn Out Part I/C Dismantling & Reconnection Complete Etc As Required. special repair Of Of Shaft Sleeve-1No. special repair Of Of Ball Bearing -2 No. special repair Of Of S.S Shaft -1 No special repair Of Of Impleller Nut -1 No special repair Of Of Gland Dori -1 No , Repairing Of 75 Hp Sewage Pump Set I/C Supply & Replacement Of Following Worn Out Part I/C Dismantling & Reconnection Complete Etc As Required. special repair Of Of Shaft Sleeve-1No. special repair Of Of Ball Bearing -2 No. special repair Of Of S.S Shaft -1 No special repair Of Of Impleller Nut -1 No special repair Of Of Gland Dori -1 No , Repairing Of 100 Hp Sewage Pump Set I/C Supply & Replacement Of Following Worn Out Part I/C Dismantling & Reconnection Complete Etc As Required. special repair Of Of Shaft Sleeve-1No. special repair Of Of Ball Bearing -2 No. special repair Of S.S Shaft -1 No special repair Of Of Impleller Nut -1 No special repair Of Of Gland Dori -1 No , Providing And Fixing Following Capacity Tp&N Disconnector Fuse Switch Unit Inside The Existing Panel Board With Isi Marked Hrc Fuses Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. 400 annual periodical maintenance , Dismantling And Rewinding The Existing Burntout 3 Phase 3Hp Submersible Pump Set In The Existing Borewell I/C Dismantling The Existing Delivery Line,Valves Etc And Lowering The Same I/C Connections, Testing Etc Complete With Followings As Required. (I)Motor Winding Kit-1No. (Ii)Bearing Bush-4No(Iii)Water Seal-2No.(Iv)E.P Stage Bowl(V)E.P.Impeller , Led Flood Light, Powder Coated Pressure Die Cast Aluminium(System Lumen Efficacy =120 And 135 Lm/Watt).Supplying,Installation, Testing & Commissioning Of Flood Light, Powder Coated Pressure Die Cast Aluminium Body With Built In Or Separatedriver As Per The Requirement With Driver Efficiency 85%, Input Voltage: Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz,Operating Temp Range -5 °C To 50 °C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Periec 61000-3-2, P. F.=0.95, Ip-66,Ik-10, Cri =70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr-15, Lenses For Beam Angle 30 Deg-120Deg As Per The Application And The Project Requirement, Suitable Tilt Able Fitting, Life Time (Led, Driver & Electricalcircuitry) Of Minimum 50000 Burning Hours With 70% Of Initial Lumen Maintained Till Life Ends As Per Lm80 Extrapolation Ies Tm-21-11Report, Cct 3000°K / 4000°K / 5700°K /6500°K (As Per Ansi Bin),Sdcm(Standard Deviation Colour Matching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq.Mm Frls/Hffr, Pvc Insulated Copperconductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy =120 And 135 Lm/Watt Output . Lm79 & Lm80 Test Report And All Testing Required For Led Fixtures As Per Bis Shall Be Submitted.. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement.(Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C).A) 200 Watt (Dsr.2025 8.15.5) , Led Street Light Fixture, Powder Coated Pressure Die Cast Aluminium Body (System Lumen Efficacy =120 135 Lm/Watt) Supplying, Installation, Testing & Commissioning Of Street Light Led Fixture Powder Coated Pressure Die Cast Aluminium Body With Driver As Per The Requirement With Driver Efficiency 85%, Input Voltage: 140-270 Volt Ac, Frequency 50/60 Hz, Operating Temp Range -5 °C To 50 °C, Internal Surge Protection Of 5 Kv L,N,E As Per Iec 61000-4-5, Driver Efficiency 85%,Thd 10% As Per Iec 61000-3-2, P. F.=0.95, Ip-66,Ik-10, Cri =70, Under Voltage And Over Voltage Protection, Emi-Emc As Per Cispr 15 , Lenses For Beam Angle As Per Iesna Type I/Ii/Iii As Per The Width Of The Road And The Project Requirement., Suitable To Fit In Up To 65Mm Dia Pipe, Life Time (Led,Driver & Electrical Circuitry) Of Minimum 50000 Burning Hours With70% Of Initial Lumen Maintained Till Life Ends As Per Lm80extrapolation Ies Tm-21-11 Report, Cct 3000°K / 4000°K / 5700°K/6500°K (As Per Ansi Bin), Sdcm(Standard Deviation Colourmatching) 5, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard Complete In All Respect I/C External Connections With 1.5 Sq Mm Frls/Hffr, Pvc Insulated Copper Conductor Single Core Cable Andearthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy =120 135 Lm/Watt Output . Lm79 & Lm80 Test Reportand All Testing Required For Led Fixtures As Per Bis Shall Besubmitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminium Housing Such That Led Junction Temperature Shall Not Rise Above 90°C).A)150 Watt (Dsr 2025- 8.13.17) , Supplying,Replacement, Testing & Commissioning Of Led Surface Mounted Batten Light Of Following Body Material And Construction As Per Is : 10322 With Driver (Replaceable) As Per The Requirement With Driver Efficiency 85% ,Operating Voltage Ac 140-270 Volt, Freq 50/60 Hz, Operating Temp Range -15 Deg To 40 Deg Centigrade, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,Thd 10% , P. F.=0.95, Ip20, Cri 80, Flicker Free, (Flicker Should Be Below 5 %), Life Time (Led,Driver & Electrical Circuitary), Of Minimum 50000 Burning Hours With , 70% Of Initial Lumen Maintained Till Life Ends, Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin), Sdcm(Standard Deviation Color Matching) 3, Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Relevant Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Complete In All Respect I/C Connections With 1.5 Sq Mm Frls, Pvc Insulated Copper Conductor Single Core Cable And Earthing Etc. As Required With Minimum 5 Year Oem Warranty. System Lumen Efficacy =120 135 Lm/Watt Output . Lm79 & Lm80 Test Report From Nabl Lab For All Testing Required For Led Fixtures As Per Bis Shall Be Submitted. Shape Size And Cct Shall Be As Approved By Engineer-In-Charge As Per Requirement. (Thermal Management: Heat Sink Of Aluminum Housing Such That Led Junction Temperature Shall Not Rise Above 90°C). Powder Coated Die Cast / Extruded Aluminium Body (Thickness = 1.20 Mm).A) 18 To 22 Watt , Supply, Replacement , Testing And Commissioning Of 1200 Mm Sweep,Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current (Bldc) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value (Cmm/W) Minimum 6.85,Air Delivery Minimum 215 Cmm,350 Rpm (Tolerance As Per Is : 374-2019), Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C (Max.), Insulation Resistance More Than 2 Mega Ohm,Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc.Complete As Required. , Supplying And Drawing Of Following Size Of Frls Pvc Insulated Copper Conductor Single Core Cable In The Existing Surface/Recessed Steel/Pvc Conduit Etc. As Required. (A) 3 X1.5 Sq. Mm , (B) 3X4 Sq.Mm , Supply & Replacement Of Following Piano Type Switch / Socket On The Existing Switch Box/ Cover I/C Connection Etc. As Reqd.(Dsr 2025 Item 1431 Pg-320) (A) 5/6 Amps Switch , (B) 15/16 Amp. Switch , (D) 6 Pin 15/16 annual periodical maintenance Socket Outlet , Providing, Laying And Replacement Of M25 Reinforced Cement Concrete Foundation Of Size 750 Mm (L) X 1000 Mm (D) And 750 Mm (W) After Removing The 12 M Pole I/C Excavation Of Earth, Providing Cutting, Bending And Placing In Position Reinforcement Of Cold Twisted Bar Of 12 Mm Dia. 900 Mm Long (Approx.) - Atleast 20 Nos. And Reinforcement Ring Of Cold Twisted Bar Of 10 Mm Dia. 4000 Mm Long (Approx.)- Atleast 6 Nos. (With 150 Mm Spacing) I/C Supplying Of 4 Nos. M-24 X 400 Mm Long (150 Mm Top Threaded & 250 Mm Top Galvanized Portion) M.S Foundation Bolt (En 8-Grade) With 3 Nos. Nuts And 2 Nos. Washer, Bolt Along With 2 Nos. Templates/Anchor Plate Of Size 320 Mm X 320 Mm X 4 Mm Thick Having 4 Nos. 24 Mm Dia. Holes To Match With Pcd Of Poles Base Plate With Positioning Of Foundation Bolts And Providing 65 Mm (Od) 2 Nos. Dwc Pipe For Cable Entry And Exit And Reinstall The Pole With The Help Of Hydra/Crane . , Fabricating ,Providing And Fixing Of M.S Connector Cover On Existing 12M High Pole With Suitable Size Made Out Of 1 Mm Thick M.S Sheet With Kabja From One Side And Another Side By Tight By 2 No.M.S Flat Clamp(1.6 Mm Thick) Nut Bolts I/C Painting With Approved Shade I/C Dismantling The Existing Damaged/Rust Connecter Cover Etc.Complete As Required , Supplying Of Following Size Of Xlpe Insulated / Pvc Sheathed Aluminium Conductor Armourd Power Cable Of 1.1 Kv Grade I/C Making, Connection Testing Etc. Complete As Req. At Site).2C X 25Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed /Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In Existing Rcc/Hume/Metal Pipe As Required A)Upto 35 Sq.Mm , Supplying And Making Straight Through Joint With Heat Shrinkable Kit Including Ferrules And Other Jointing Materials For Following Size Of Pvc Insulated And Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Reuired . A) 2*25 S.Mm (Dsr Item) , Providing A Motorised Man Lift Crane Suitable Upto 12 Mtr Street Light Poles For Replacement And Rectification Of Street Light Fittings Mounted On 12 Mtr Pole Complete As Required.
|