|
G L O B A L Hiring A Company Specialized In Providing Maintenance Services For Window And Split Type Air Conditioners. Services Include Installation, Cleaning And Lubrication, Gas Refilling And Parts Replacement. - Complete Installation Of Split Type Air Conditioning Equipment From 7,500 To 12,000 Btus. Including The Obligation Of At Least 3 Meters Of Line, Regardless Of The Distance Between The Evaporator And Condenser, Consisting Of A Condenser Unit And 1 Evaporator Unit., Gas Refilling And Replacement Of Parts. - Complete Installation Of Split Type Air Conditioning Equipment From 18,000 To 24,000 Btus. Including The Obligation Of At Least 3 Meters Of Line, Regardless Of The Distance Between The Evaporator And Condenser Consisting Of A Condensing Unit And 1 Evaporator Unit, Gas Refilling And Replacement Of Parts. - Complete Installation Of Split Type Air Conditioning Equipment From 24,000 To 30,000 Btus. Including The Obligation Of At Least 3 Meters Of Line, Gas Refilling And Parts Replacement. - Complete Cleaning Of Split Type Air Conditioning Equipment (Condenser And Evaporator). The Heat Exchanger (Coil), Axial Fan, Fairing, Drain Gutter And All Components Must Be Cleaned. It Is Necessary To Remove The Equipment That Is Installed. The Service Will Include All The Supplies Necessary To Perform The Service And Subsequently Reinstall The Equipment (7,500 A Equipment 12,000 Btus), Gas Recharge And Parts Replacement. - Complete Cleaning Of The Split Type Air Conditioning Equipment (Condenser And Evaporator.) The Heat Exchanger (Coil) Must Be Cleaned. 04/16/2026 - 10:49:22, 04/16/2026 - 11:12:47, 04/16/2026 - 11:13:24, The Service Will Include All Supplies Necessary To Execute The Service And Subsequent Reinstallation Of The Equipment (Equipment With More Than 24,000 Btus), Gas Refilling And Parts Replacement. - Removal From The Site And Reinstallation In Another Location Of Split-Type Air Conditioning Equipment From 7,500 To 12,000 Btus, Including The Obligation Of At Least 2 Meters Of Line, Regardless Of The Distance Between The Evaporator And Condenser Consisting Of 1 Condenser Unit And 1 Evaporator Unit, Gas Refilling And Replacement Of Parts. - Removal From The Site And Reinstallation In Another Location Of Split-Type Air Conditioning Equipment From 18,000 To 24,000 Btus, Including The Obligation Of At Least 2 Meters Of Line, Gas Refilling And Replacement Of Parts. - Removal From The Site And Reinstallation In Another Equipment Location. Of Air Conditioning. Split Type 30,000 Btus Btus Including The Obligation Of At Least 2 Meters Of Line, Regardless Of The Distance Between The Evaporator And Condenser Composed Of 1 Condensing Unit Composed Of 1 Evaporator Unit, Gas Recharge And Parts Replacement. - Provision Of Labor Service Corrective Maintenance Of Air Conditioning By Call Provision Of Labor Service Corrective Maintenance Of Air Conditioning By Call, Gas Refilling And Parts Replacement. - R22 Refrigerant Gas For Air Conditioning Kg, Gas Recharge And Parts Replacement. - R32a Refrigerant Gas For Air Conditioning Kg, Gas Refilling And Parts Replacement. - R410a Refrigerant Gas For Air Conditioning Kg, Gas Refilling And Parts Replacement. - Additional Metro Line P
|