|
Grandstand 30 Meters Long, 06 Steps, Made Of 75 Cm Boards, Galvanized Structure, Non-Slip Surface, Seat With 75 Cm Wide Boards, 1.20 M High Railing, Access Stairs, Parapet And Handrail, Externally Covered With Flame-Retardant Night And Day Tarpaulin. Access Ramp For People With Physical Disabilities, With A Slight Decline. Locking System With Grid And Wedge, Providing Greater Security., Grandstand 45 Meters Long, 12 Steps, Dressing Rooms With An Area Of 5X5m Each, To Be Installed In An Area Adjoining The Stage Or Above It. Material For Dressing Room: Octanorm And Ts Standard Sheets, 2.70M High. The Dressing Room Ceiling Must Be Closed. Each Dressing Room Must Have An Electrical Network, Including The Installation Of At Least Three Sockets And Adequate Lighting For The Space. Furniture/Equipment For Each Dressing Room: 1 12Btus Air Conditioning Unit; 1 Refrigerator; 4 High Stools; 01 Full Length Mirror, 01 Round Table With Four Chairs, 01 03-Seater Sofa, Internal Sanitary Installation (With Daily Cleaning), Deck Flooring Throughout The Dressing Room Installation And Tents For Coverage. All Safety Equipment Required By The Fire Department, Fire Extinguishers Etc, Gradio Disciplinadores, To Control The Entry And Exit Of The Public, Made In Galvanized Tubular Structures, Dimensions Of 2.00M 08 Reinforced Rectangular Bases 0, 70X0, 70, 08 Reinforced Load Sticks, 08 1 Ton Hoists, 600 Screws., 04/15/2026 - 16:05:14, 04/15/2026 - 16:05:15, Led Panel With Minimum Definition P3.9, With Assembly, Operator And Expenses Included! - Outdoor - Ideal For External Or Internal Areas That Demand Higher Quality But Do Not Compromise On Price, The P3.9 Outdoor Led Is Made Up Of Modules Measuring 250 X 250 Mm Each With An Image Resolution Of 65,536 Pixels Per M² And An Emitted Brightness Of An Incredible 6000 Nits. Iron Cover/Side Protection, With A Height From The Ground Of Up To 0.80 Cm, With A Ladder Of At Least 5 Steps With Handrails, Iron Structure, With Floor., Stage Type 1 – Small Stage With Approximate Measurements Of 8M 500Kgf/M², Tubular Structure In 1 1/4 Galvanized Tube, Plank Floor, Covering With 2 (Two) Flame-Resistant Tarpaulins, Bottom And Sides In Shade, Ceiling Foot Of At Least 4M, With Carpet On The Entire Floor, 1.50M Height From Ground To Floor, Access Ladder With Handrail, Railing With 1, 10M High In Reinforced Metalon Grid, 1 Housemix With Coverage In Black Fabric On The Entire Side Structure And Front Of The Floor., Type 2 Stage –_Medium Size (Two Waters) Stage With Approximate Measurements 12M (Two) Waters, In Aluminum Structure Type Box Truss Q30 Or Similar, With Flame-Retardant Canvas, Grid For Sound And Lighting System (Stage) And “Wings” On The Sides For Fly System. Smooth. Two Access Stairs With Handrails, Housemix Measuring 4M
|