Non-Liquefied Medicinal Oxygen: Characteristics: Non-Liquefied Medicinal Oxygen With A Purity Degree Of 99.5 Supplied In Steel Cylinders With A Capacity Of 2.0 To 10.0M³. Note: The Steel Cylinders Necessary For The Storage And Transport Of Medicinal Gases Will Be Provided By The Contractor On A Lending Regime (Free Loan). The Contracting Party Will Pay Exclusively For The Volume Of Gas Actually Supplied (Recharge), Measured In Cubic Meters (M³), With The Contractor Being Solely Responsible For The Maintenance, Hygiene And Validity Of The Hydrostatic Tests On The Cylinders Made Available. 6.0M³, 19.5 To 23.5 V.V. Of O2, Maximum Impurities: Thc Less Than 5Ppm, H2o Maximum 80Ppm, With Maximum 10Ppm. Note: The Steel Cylinders Necessary For The Storage And Transport Of Medical Compressed Air Will Be Provided By The Contractor On A Lease Agreement (Free Loan). The Contractor Will Pay Exclusively For The Volume Of Compressed Air Effectively Supplied (Recharge), Rental Of Medical Air Generating Plant: Rotary Screw Type Capacity 20M³. Characteristics: Rotating Screw Type, With Minimum Effective Production Capacity Of 20M³/H At Working Pressure Of 8 Bar, According To Term Of Reference And Its Annexes, Must Be Composed Of: Two Rotating Screw Type Compressors, Working Pressure Of 125 Psi, 220V Tri-Phase Voltage, Frequency 60Hz. The Medical Air System Must Follow The Technical Standards And Recommendations Of The Abnt - Nb12188, Of The Ministry Of Health - Ordinance Rdc N 50 Of February 21, 2002 And Its Amendments. The System Must Meet A Minimum Effective Production Capacity Of 20 M³/H At A Working Pressure Of 8 Bar. The System Must Produce Medical Air With The Following Characteristics: N2 Balance 02 20, 4 To 21 V/V Of Oxygen Particles ≪ 0.1 Mg/M3 Waste Oil ≪ 0.1 Mg/M3 Water Vapor: 67 Ppmmax (Or-Value Point - 45.5 C, Referring To Atmospheric Pressure) Co2 500 Ppmmax Co 5 Ppmmax So2 1 Ppmmax Nox 2Ppm Max Odor And Flavor - Free High Efficiency Coa-Lescent Pre-Filters For Removal Of Oil, Reducing Moisture Level And Particles Down To 0.01 Microns (Remaining Oil Content Of 0.01 Mg/M3 Max); Bacteriological Filter Of 0.01 Micron And 99.99 Efficiency, Provided With Cartridge, Proven In Each Unit During Its Manufacture, Allowing Highly Efficient Battery Retention: Coalescent Post-Filter And Activated Carbon With Retention Of Particles Of Up To 0.01 Microns And Re-Manescence..., Rental Of Central Generators Vacuum: Screw Or Lobe Type, Single Stage, Minimum Flow 20M³/H, Operating Vacuum 690Mmhg. Characteristics: Rental Of A Vacuum Generator Center, Of Equal Capacity, Screw Or Lobe Type, Operating Vacuum 690Mmhg, Effective At Sea Level, As Per The Terms Of Reference And Its Annexes, And Must Be Composed Of: Two Vacuum Generating Units, Air-Cooled, Suggested Minimum Flow Of 20 M³/H, Operating Vacuum 690Mmhg, Effective At Sea Level; The Medical Vacuum System Must Follow The Technical Standards And Recommendations Of Abnt Nb12.188 -. From The Ministry Of Health Ordinance Rdc 50 Of February 21, 2002. Visual And Audible Alarm System That Can Operate With The Hospitals Emergency Electrical System, In The Event Of A Breakdown Or Power Outage: The Pump Must Be Controlled
|