|
01 Simple Key 10A - 250V, Fence For Sports Court With Galvanized Wire Mesh, Fixed To Galvanized Steel Tube Frames, H=1M, H=2M, Masonry Sealing With Concrete Block, 14X19x39 Cm, Wall Thickness 14 Cm, 10Mm Joints With Mortar Mixed Cement, Hydrated Lime And Unsifted Sand Traco 1:0, 5:8, Steel Reinforcement, Ca 50, Cutting And Bending On Site, 04/10/2026 - 13:38:07, Steel Reinforcement Ca 60B (Welded Steel Mesh Ca 60 With 100X100mm D=4, 20Mm Of Wire And Annealed Wire) Note: 2, 20Kg/M2, Manually Compacted Landfill, With Socket, Extra Tile Layed Internally With Pre-Fabricated Adhesive Cement Mortar, Including With Internal Or External Grouting, Granite Countertop For Sink Or Washbasin E=3Cm, Supported On Metalon Console, Internal Bench In Concrete And Masonry, Varnish Finish, E = 8 Cm, L = 40 Cm, Deficient Support Bar Stainless Steel Tube 1 1/4 L=100Cm For Wall, Deficient Support Bar Stainless Steel Tube 1 1/4 L=80Cm For Sink Support, Wooden Shed, Cemented Floor And Roof In Corrugated Fiber Cement Tiles, Inspection Box Or Passage In Masonry 60 Automatic, 220V-5400W, Galvanized Steel Roofing, Wavy Profile, Esp. 0.5 Mm, Crushed Stone Mattress (Crushed Ballast 3 And 4 Manually Piled With A 30 Kg Mallet), Reinforced Concrete (Including Supply, Transport, Casting, Shaping And Deformation), Reinforced Concrete For Foundation (Including Supply, Structural Concrete Poured On Site, Control A, Consistency For Vibration, Crushed Stone 1, Fck = 20 Mpa And Casting On Foundation, Concrete Fck=25Mpa, E=8Cm Cast On Court Floor, Executed In A Single Stage, For Mechanical Polishing, Including Joints Or Cuts In Plates Not Larger Than 4.0 M2 And Surface Mechanical Polishing, Water Conductor (White Pvc Tube, With Connections, Bag End And Ferrule, Section Diameter 100Mm), 3/4 Hp Motor-Pump Lift Assembly (Centrifugal Pump), Double Handrail In Galvanized Steel Tube D = 1 1/2 - Fixed In Masonry, Court Demarcation (Acrylic Paint On Floor For Demarcation Strips, With Strips Of 5 Cm And 8 Cm Wide, Applied With Brush), Circuit Breaker With Residual Differential Protection (Dr), Bipolar, Din Type, Nominal Current Of 25A, High Sensitivity, Nominal Residual Differential Current With Actuation Of 30Ma, Swallow Gray Granite Divider (Including All Chromed Brass Hardware), E = 3Cm, Hygienic Shower With 1/2 Water Flow Control Tap, Inlet With Mortar 1:6 Cement And Washed Sand Medium Screened, For Walls Coated With Paint, E = 20Mm, Sports Equipment (Volley, Futsal, Basketball) All Together, Manual Excavation Of Trench In Soil Of 1St And 2Nd Category, Depth Of Up To 2.00M, Manual Excavation In Open Field In Soil Except Rock With Depth Of Up To 2, Manual Excavation Of Open Pit Pipes, Steel Structure For Arched Roof, Spacing Between Arches Of 6.0 M, Span Of 30, In Steel To 36, Including Assembly, Locks For Internal Door, Wooden Form For Foundation, With Boards And Battens, 3 Uses And Deformation, Supply And Installation Of Threadable Pvc Conduit, With Connections: Diameter 20Mm (3/4), With Connection
|