|
Bids Are invited for Conductivity Analyzer Element Contacting Type plus Transmitter, Range 0-100 microsiemens, Element Make-Model-ROSEMOUNT 400-11, Transmitter Make-Model-ROSEMOUNT 1066-C-HT-60. - Conductivity Analyzer Element (Contacting Type)+Transmitter, Range 0-100 microsiemens, Element Make/Model-ROSEMOUNT/400-11, Transmitter Make/Model-ROSEMOUNT/1066-C-HT-60. , Differential Pressure Transmitter, Range 0-0.6 kg per cm2, Make-ROSEMOUNT Model-2051CD2A03A1BS5M5Q4 plus 305RC32B11B4L4. - Differential Pressure Transmitter, Range 0-0.6 kg/cm2, Make-ROSEMOUNT Model-2051CD2A03A1BS5M5Q4+ 305RC32B11B4L4. , Orifice Plate plus Diaphragm Type Pressure Transmitter, Range 0-80 m3 per hr, Make-ROSEMOUNT Model-2051CD2A03A1BS5M5Q4 plus 305RC32B11B4L4. - Orifice Plate + Diaphragm Type Pressure Transmitter, Range 0-80 m3/hr, Make-ROSEMOUNT Model-2051CD2A03A1BS5M5Q4+ 305RC32B11B4L4. , Diaphragm Type Pressure Transmitter, Range 0-1.3 kg per cm2 abs, Make-ROSEMOUNT, Model-2088A1S33A1M5B4D4Q4S5 plus 0306RT22BA11. - Diaphragm Type Pressure Transmitter, Range 0-1.3 kg/cm2 abs, Make-ROSEMOUNT, Model-2088A1S33A1M5B4D4Q4S5+0306RT22BA11. , Diaphragm Type Pressure Transmitter, Range 0-1.6 kg per cm2 abs, Make-ROSEMOUNT, Model-2088A1S33A1M5B4D4Q4S5 per 0306RT22BA11. - Diaphragm Type Pressure Transmitter, Range 0-1.6 kg/cm2 abs, Make-ROSEMOUNT, Model-2088A1S33A1M5B4D4Q4S5+0306RT22BA11. , Diaphragm Type Pressure Transmitter, Range 0-5 kg per cm2 abs, Make-ROSEMOUNT, Model-2088A1S33A1M5B4D4Q4S5 per 0306RT22BA11. - Diaphragm Type Pressure Transmitter, Range 0-5 kg/cm2 abs, Make-ROSEMOUNT, Model-2088A1S33A1M5B4D4Q4S5+0306RT22BA11. , Diaphragm Type Pressure Transmitter, Range 0-10 kg per cm2 abs, Make-ROSEMOUNT, Model-2088A1S33A1M5B4D4Q4S5 plus 0306RT22BA11. - Diaphragm Type Pressure Transmitter, Range 0-10 kg/cm2 abs, Make-ROSEMOUNT, Model-2088A1S33A1M5B4D4Q4S5+0306RT22BA11. , Diaphragm Type Pressure Transmitter, Range 0-11 kg per cm2 abs, Make-ROSEMOUNT, Model-2088A1S33A1M5B4D4Q4S5 plus 0306RT22BA11. - Diaphragm Type Pressure Transmitter, Range 0-11 kg/cm2 abs, Make-ROSEMOUNT, Model-2088A1S33A1M5B4D4Q4S5+0306RT22BA11. , Diaphragm Type Pressure Transmitter, Range 0-6 kg per cm2 abs, Make-ROSEMOUNT, Model-2088A1S33A1M5B4D4Q4S5 plus 0306RT22BA11. - Diaphragm Type Pressure Transmitter, Range 0-6 kg/cm2 abs, Make-ROSEMOUNT, Model-2088A1S33A1M5B4D4Q4S5+0306RT22BA11. , Diaphragm Type Pressure Transmitter, Range 0-12 kg per cm2 abs, Make-ROSEMOUNT, Model-2088A1S33A1M5B4D4Q4S5 plus 0306RT22BA11. - Diaphragm Type Pressure Transmitter, Range 0-12 kg/cm2 abs, Make-ROSEMOUNT, Model-2088A1S33A1M5B4D4Q4S5+0306RT22BA11. , Vibrating Level Switch, Make-ROSEMOUNT, Model-2120D1DV1NAAA0000. , Radar Type Level Transmitter, Range 0-760mm, Make-ROSEMOUNT, Model-5408A1SHA1NA7R3AASAA3Q4. , Radar Type Level Transmitter, Range 0-14m, Make-ROSEMOUNT Model-5408A1SHA1NA7R3AASAA3Q4. , Temperature Element RTD, Range 0-100 degC, RTD Make-Model-ROSEMOUNT 214CRWMA1D3E0077SLAT1C3UAE030X8Q4 plus 114CE0060TAC2SC017B. - Temperature Element (RTD), Range 0-100 degC, RTD Make/Model-ROSEMOUNT/214CRWMA1D3E0077SLAT1C3UAE030X8Q4+ 114CE0060TAC2SC017B. , Diaphragm Type Pressure Transmitter, Range 0-4 kg per cm2, Make-ROSEMOUNT, Model-2088A2S33A1M5B4D4Q4S5 plus 0306RT22BA11. - Diaphragm Type Pressure Transmitter, Range 0-4 kg/cm2, Make-ROSEMOUNT, Model-2088A2S33A1M5B4D4Q4S5+0306RT22BA11. , pH analyzer and Tranmitter, Range 0-14, Element Make-Model-ROSEMOUNT 3900-02-10, Transmitter Make-Model-ROSEMOUNT 1066-P-HT-60. - pH analyzer & Tranmitter, Range 0-14, Element Make/Model-ROSEMOUNT/3900-02-10, Transmitter Make/Model-ROSEMOUNT/1066-P-HT-60. , Chlorine Analyzer and Transmitter, Make Rosemount, Model FCL-02-221 plus 1056-02-24-32-AN. - Chlorine Analyzer & Transmitter, Make Rosemount, Model FCL-02-221+1056-02-24-32-AN. Total Quantity : 48
|