|
Flexible Cable 2.5Mm. Flexible Cable 2.5Mm., Flexible Cable 4.00Mm. Flexible Cable 4.00Mm., Flexible Cable 6.00Mm. Flexible Cable 6, Capacitor 2.5 Uf, Model Cbb61 Tolerance +-5%; Voltage: 450Vac, 50/60Hz, Capacitance Tolerance +-5%; Dissipation Factor 20X10-4 (100Hz, 20 #8451); Terminal Voltage Test For Onu Utt2 Terminal For 2 Seconds; Terminal Voltage Test For Tuc Case, Capacitor 20Mf + Or 5%, 450-Vac-Pin 50/60 Hz Operation Class Class B (10,000H) Class C (3,000H); Safety Protection Class P2/P1; Voltage Range 200-500 Vac; Capacitance Range 2~120Mf; Capacity Tolerance ±5%; Dissipation Factor 20 Terminal Voltage Test For Utc Case (2Un +1000) Vac Or 2000Vac Or 2000Vac-50Hz For 60 Seconds; Insulation Resistance =3000Mo Mf (100Hz, 15 #8451; 1 Min), 04/07/2026 - 13:12:29, 04/07/2026 - 13:12:37, Capacitor 3 Uf Model Cbb61 Tolerance +-5%; Voltage: 450Vac, Capacitor 35Mf + Or 5%, Capacitor 40Mf + Or 5%, Capacitor 45Mf + Or 5%, Capacitor 5 Uf Model Cbb61 Tolerance +-5%; Voltage: 450Vac, Mini Box Capacitor 1.5Mfd+Or -5%- 450V With Double Terminal Capacitor 1.5Uf, Tolerance +-5%; Voltage 450Vac, Mini Box Capacitor 2Mfd+Or -5%- 450V With Double Capacitor Terminal 1, Tolerance +-5%; Voltage: 450Vac, Compressor E 240 With 24,000 Btus Rotary Capacity 1 Ph Lra22.0 Voltage 208/~220V Frequency: 60Hz - Gas Type: R22 Suction Line Connection: 3/8 Discharge Line Connection: ¼, Compressor E 240 With 12,000 Btus Rotary Capacity 1 Ph Lra26.0 Voltage 208/~220V- Frequency: 60Hz Gas Type: R22 Suction Line Connection: 1/2 Discharge Line Connection: ¼, Compressor E 240 Com. 18,000 Btus Rotary Capacity 1 Ph Lra42.0 Voltage 208/~220V- Frequency: 60Hz Type Of Gas: R22 Suction Line Connection: 1/2 Discharge Line Connection: ¼, Compressor E 240 Com. 30,000 Btus Rotary Capacity Ph 401X3cx-3Muu Voltage 208/~220V Frequency: 60Hz Gas Type: R22 Suction Line Connection: 5/8 Discharge Line Connection: 3/8, 20M Insulating Tape 20M Insulating Tape, R22 Refrigerant Gas For Air Conditioning Kg, R32a Refrigerant Gas For Kg Air Conditioning, R410a Refrigerant Gas For Kg Air Conditioning, Complete Installation Of Split Type Air Conditioning Equipment From 18,000 To 24,000 Btus. Including The Obligation Of At Least 3 Meters Of Line, Regardless Of The Distance Between The Evaporator And Condenser, Consisting Of A Condenser Unit And 1 Evaporator Unit, Complete Installation Of Split-Type Air Conditioning Equipment From 24,000 To 30,000 Btus. Including The Obligation Of At Least 3 Meters Of Line, Complete Installation Of Split Air Conditioning Equipment From 7,500 To 12,000 Btus. Including The Obligation Of At Least 3 Meters Of Line, Regardless Of The Distance Between The Evaporator And Condenser, Consisting Of A Condenser Unit And 1 Evaporator Unit. All Necessary Supplies Will Be Included To Carry Out The Service And Subsequent Reinstallation Of The Equipment., Complete Cleaning Of The Split Air Conditioning Equipment (Condenser And Evaporator). The Heat Exchanger (Coil), Axial Fan, Fairing, Drain Gutter And All Components Must Be Cleaned, Requiring The Removal Of The Equipment
|