Prior Information Notice For X-Ray Devices – Zp-03/2026. 1.The Supplied Equipment Must Be Brand New And Come From A Distribution Network Intended For The Eu Market And Have An Eu Declaration Of Conformity. 2. The X-Ray Device Must Be Entered In The Register Of Medical Devices In Poland, 3. Fully Digital Equipment, 4. Automatic Positioning Of The Lamp And Lung Stand And Subsequent Gluing Of Images - Stitching For Postural Photos. 5. Stitching Is Treated As Additional Equipment Not Required By The Ordering Party, 6. Cap (Head) With A Lamp; Lamp Rotation In Two Axes; Automatic Collimator With Illumination Of The Imaging Field, Laser Concentrator; Collimator Equipped With An Additional Set Of Filters, Screen, At Least 9 Inches On The Lamp Housing Allowing You To Control The Camera And Manipulate Exposure Parameters (Generator); Lcd Or Led Screen On The Cap With A Lamp For Displaying Information About The Sid Distance To The Table And Stand, Displaying Generator Parameters And Aec; X-Ray Tube, Anode Heat Capacity At Least 300 Khu, Bifocal At Least 0.6/1.3 Mm Or Smaller; System For Measuring Dose With Foci No Larger Than: Small Focus 0.6X0.6; Large Fireplace 1.3X1.3, 6.1. A Cap (Head) With A Lamp Attached To The Ceiling (Ceiling Suspension - Optional) - Lamp Rotation In Two Axes. -Automatic Collimator With Illumination Of The Imaging Field, Laser Center. -Collimator Equipped With An Additional Set Of Filters ……. -3D Camera For Viewing The Patient Built Into The Collimator. -Automatic Detection Of The Position Of The Spine Or Legs By The Algorithm And Automatic Determination Of The Scope Of Examination Of Long Bones. -A Screen Of At Least 9 Inches On The Lamp Housing Allowing You To Control The Camera And Manipulate Exposure Parameters (Generator). -Lcd Or Led Screen On The Cap With A Lamp For: Displaying Information About The Sid Distance To The Table And Tripod, Displaying Generator Parameters And Aec. -Range Of Motor Movement Of The Column With The X-Ray Lamp: Min. 350+/-10% Cm Longitudinally And Min. 210+/-10% Cm Transversely. -Rotation Of The Lamp Around The Vertical Axis Of The Column 180° +/- 10%. -Rotation Of The Lamp Around The Horizontal Axis Of The Column ±135°+/-10%. -Range Of Vertical Movement 180 Cm +/-15%, Enabling The Diagnosis Of Patients On Orthopedic Tractions 7. Floating Table With A Wide Range Of Adjustments; Possible Longitudinal Movement Of The Detector Drawer; Automatic Detector Power Charging System In The Drawer; Maximum Table Load: At Least 250 Kg; Anti-Scatter Grille Removable Without Tools: Holding The Patients Hands/Possibility Of Limiting The Patients Movements, 8. Pulmonary Stand; Attached To The Floor And/Or Wall; Mechanized – Synchronization With The Lamp; Distance From The Center Of The Detector, Counted From The Floor In The Vertical Position Of The Panel: Min. 45Cm +/-10Cm; Max. 170 Cm +/- 10 Cm (Please Provide Your Dimensions); Motorized Tilting Of The Tripod Panel Up To 90° (Is It Available, How Much Does It Cost); Tripod Panel Rotation Of At Least 90°; Possibility Of Removing And Replacing The Grille Without Tools; Holding The Patients Hand For Performing Examinations In Lateral Projections
Contact Information
Contact No.
0048124467506
Email
maciejewskim@mco.krakow.pl
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 111333436
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.