Tenders Are Invited For Refrigeration Split System Medium Temperature Cooling Capacity Q=2.154 Kw At Dt=8K ( ... in Belarus
Tender Notice
TenderID
111072453
Tender Brief
Tenders Are Invited For Refrigeration Split System Medium Temperature Cooling Capacity Q=2.154 Kw At Dt=8K (Pos. 8,8.1)Pcs1 Multi-Compressor Unit, Freon (R507a) Based On 2 Piston Compressors (Pos.1,2)Pcs2 Air Cooler Suspended.Cubic. Cooling Capacity Q=11.7 Kw At Dt=7K (Pos.1.1,1.2,2.1,2.2)Pcs4 Multi-Compressor Unit, Freon (R507a) Based On 2 Piston Compressors (Pos.3,4)Pcs2 Air Cooler Hanging.Cubic. Cooling Capacity Q=15.8 Kw At Dt=7K (Pos.3.1.4.1) Pcs2 Unit, Freon (R507a) Based On 1St Piston Compressor (Pos.5) Pcs1 Suspended Air Cooler. Cubic. Cooling Capacity Q=6 Kw At Dt=8K (Pos.5.1)Pcs1 Unit, Freon (R448a) Based On Piston Compressor (Pos.6)Pcs1 Suspended Air Cooler. Cubic. Cooling Capacity Q=7.0 Kw At Dt=8K (Pos. 6.1)Pcs1 Refrigeration Split System Low Temperature Cooling Capacity Q=2.66 Kw At Dp=7K (Pos. 7.7.1)Pcs1 Filter Dryer F16 Mmsht2 Filter-Drier F16 Mmsht2 Filter-Drier F16 Mmsht1 Filter-Drier F18 Mmsht1 Filter-Drier F18 Mmsht1 Filter-Drier F10 Mmsht1 Filter-Drier F10 Mmsht1 F
Refrigeration Split System Medium Temperature Cooling Capacity Q=2.154 Kw At Dt=8K (Pos. 8,8.1)Pcs1 Multi-Compressor Unit, Freon (R507a) Based On 2 Piston Compressors (Pos.1,2)Pcs2 Air Cooler Suspended.Cubic. Cooling Capacity Q=11.7 Kw At Dt=7K (Pos.1.1,1.2,2.1,2.2)Pcs4 Multi-Compressor Unit, Freon (R507a) Based On 2 Piston Compressors (Pos.3,4)Pcs2 Air Cooler Hanging.Cubic. Cooling Capacity Q=15.8 Kw At Dt=7K (Pos.3.1.4.1) Pcs2 Unit, Freon (R507a) Based On 1St Piston Compressor (Pos.5) Pcs1 Suspended Air Cooler. Cubic. Cooling Capacity Q=6 Kw At Dt=8K (Pos.5.1)Pcs1 Unit, Freon (R448a) Based On Piston Compressor (Pos.6)Pcs1 Suspended Air Cooler. Cubic. Cooling Capacity Q=7.0 Kw At Dt=8K (Pos. 6.1)Pcs1 Refrigeration Split System Low Temperature Cooling Capacity Q=2.66 Kw At Dp=7K (Pos. 7.7.1)Pcs1 Filter Dryer F16 Mmsht2 Filter-Drier F16 Mmsht2 Filter-Drier F16 Mmsht1 Filter-Drier F18 Mmsht1 Filter-Drier F18 Mmsht1 Filter-Drier F10 Mmsht1 Filter-Drier F10 Mmsht1 Filter-Drier F12 Mmsht1 Filter Dryer F12 Mmsht1 Electronic Expansion Valve E2v24sht2 Electronic Expansion Valve E2v24sht2 Electronic Expansion Valve E2v24sht1 Electronic Expansion Valve E2v24sht1 Electronic Expansion Valve E2v30шт1 Electronic Expansion Valve E2v30шт1 Electronic Expansion Valve E2v11шт1 Electronic Expansion Valve E2v11шт1 Cable For Connecting Erv Spkc002310 3Мшт10 Door Limit Switch (Reed Switch)Shт8 Pressure Equalization Valve In The Chamber Kvd-30-250Шт5 Boss Dispatching System Unit Bmнst03xs0шт1 Manual Address System Chk-10Шт1 Interfacing Device Chk-10Sht5 Air Temperature Sensor Ntc015нp00шт18 Exit Button With Backlightsht5 Evaporator Temperature Sensor Ntc015нp00шт10 Lightning Scoreboard 24 People In A Camerasht5 Temperature Sensor Overheating Ntc015нf00шт10 Pressure Sensor Spkt00b6rшт10 Connecting Cable For Low Pressure Sensor Spkc002310шт10 Erv E2vcabшт10 Cooled Chamber Control Remote U2-1-5А-1F-13Квтшт2 Control Remote For Cooled Chamber K1-Мрх-15-380Шт2 Control Remote For Cooled Chamber K1-Мрх-06-380Шт2 Drainage Ten L=6000Mm 30W 230Vшт3
Contact Information
Contact Person
Ольга Анатольевна + 375 447530517tender@bmsu4.by
Address
Республика Беларусь, г. Минск, 220035, ул. Тимирязева, д. 67, пом. 228 (внутренний номер помещения 1525)
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 111072453
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.