Construction Work – Renewal Of The Lighting System On The Main Campus. The Outdoor Lighting Is Equipped Almost Everywhere With Safety Lighting In Accordance With Din En 1838_2025-03. A Large Number Of The Aforementioned Mast And Bollard Lights Are Therefore Also Controlled With Safety Lighting. Mast And Bollard Lights Are Therefore Necessary That Can Process Both Controls, General And Safety-Supplied Supply Lines. The Battery-Backed Safety Lighting Centers Are Set Up In The Aforementioned Buildings. For Reasons Of Compatibility, It Is Necessary To Install Systems From The Manufacturer Ceag. Where It Is Not Structurally Possible To Create Complete Rooms, F30 Cabinet Systems Are Used In The Rooms To Provide Security. The Electrical Supply To These Facilities Comes From The Buildings Existing Nshv Systems. To Ensure Reliability, Modern Battery Centers From Eaton (Ceag) Are Installed, Which Are Located In The Respective Technical Rooms And Reliably Power The Emergency Lighting Systems In The Event Of A Mains Power Failure. The Four Locations Also Serve As Central Information Centers Through Which All Lighting And Security Functions Can Be Brought Together, Monitored And Controlled. Integration Into The Higher-Level Building Automation Takes Place Via The Existing It Network Using Bacnet Communication. The Central Building Management System Is To Be Connected To The Ibms System (Integrated Building Management System) From Inga Mbh From Hameln. This System Enables Uniform, Location-Independent Management And Diagnosis Of All Integrated Components. A Comprehensive Overall Visualization For The Entire Campus Area Will Be Set Up At One Of The Information Focal Points. This Serves As A Central Operating And Monitoring Interface And Displays All Relevant Operating States, Fault Messages And Control Functions Throughout The System. The Other Key Information Areas Each Receive A Local Manual Control Level That Is Specifically Tailored To The Respective Supply Area. This Ensures Flexible And Locally Independent Control Of The Outdoor Lighting And Security Systems.
Contact Information
Address
Universitätsallee 1
Contact No.
+49 4131677-0
Email
vergabestelle@leuphana.de
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 111070358
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.