|
Work Of 11 Kv, 33 Kv Cable, 33 Kv Switchyard And Others Work Under Business Plan 2025-26 In The Area Of Jurisdiction Of Edd-Pilkhuwa Under Edc-Hapur. (44 No. Works)- 2 Cable Ht Xlpe 3X185 Sqmm 11 Kv With Double Circuit 3 Cable Box 3X185 O/D Sqmm 11 Kv 4 11 Kv Vcb For Outgiong Ctr 200/100/5A 350 Mva (1250 Mva) Steelmake 5 11 Kv Fuse Set 6 Pcc Pole 8.5 Mtr Long. 7 11 Kv Pin Insulator Polymer 8 11 Kv Disc Insulator Polymer 9 M.S. Channel 100X50X50 Mm 10 Earthing Complete 11 11 Kv Xipe Cable 3X300 Sqmm With Double Circuit 12 11 Kv O/D Xipe 3X300 Sqmm C/J Kit 13 11 Kv Through 3X185 Sqmm Xlpe C/J Kit 14 33 Kv Circuit Breaker 800A, 750 Mva 15 Acsr Dog. Conductor 16 Cable Ht Xipe 3X300 Sqmm 33 Kv 17 Cable Box 3X300 O/D Sqmm 33 Kv 18 H/S 33 Kv 3X300 Sqmm J/Kit St. Th 19 Cable H.T.Xlpe 11 Kv 3X300 Sq.Mm. 20 11 Kv Vcb Incoming 21 33 Kv Pt Outdoor (2Set) (2X3=6) 22 Battery Set 24 Volt 23 Battery Charger 24 Volt 24 33 Kv Ct 400/200/1 Amp 25 33 Kv Ct 200/100/1 Amp 26 33 Kv Control Pannel Double T/F 27 33 Kv Fuse Set 28 Earth Wire 7/14 Swg 29 Earth Rod 2540X20 30 Eraction And Fixing And Making Connection Of Following Material (As Per Respo Norms) At Diffrent 33/11 Kv Substation Were Include Making Alignment, All Required Nut Bolt, Clamps, Lug, Connector, Wire And Strip Etc All Labour,T&P, Safe & Porper Oprations Provided By Contractor In All Respects. 31 Cable Ht Xlpe 3X185 Sqmm 11 Kv With Double Circuit 32 Cable Box 3X185 O/D Sqmm 11 Kv 33 11 Kv Vcb For Outgiong Ctr 200/100/5A 350 Mva (1250 Mva) Steelmake 34 11 Kv Fuse Set 35 Pcc Pole 8.5 Mtr Long. 36 11 Kv Pin Insulator Polymer 37 11 Kv Disc Insulator Polymer 38 M.S. Channel 100X50X50 Mm 39 Earthing Complete 40 11 Kv Xipe Cable 3X300 Sqmm With Double Circuit 41 11 Kv O/D Xipe 3X300 Sqmm C/J Kit 42 11 Kv Through 3X185 Sqmm Xlpe C/J Kit 43 33 Kv Circuit Breaker 800A, 750 Mva 44 Acsr Dog. Conductor 45 Cable Ht Xipe 3X300 Sqmm 33 Kv 46 Cable Box 3X300 O/D Sqmm 33 Kv 47 H/S 33 Kv 3X300 Sqmm J/Kit St. Th 48 Cable H.T.Xlpe 11 Kv 3X300 Sq.Mm. 49 11 Kv Vcb Incoming 50 33 Kv Pt Outdoor (2Set) (2X3=6) 51 Battery Set 24 Volt 52 Battery Charger 24 Volt 53 33 Kv Ct 400/200/1 Amp 54 33 Kv Ct 200/100/1 Amp 55 33 Kv Control Pannel Double T/F 56 33 Kv Fuse Set 57 Earth Wire 7/14 Swg 58 Earth Rod 2540X20 59 Providing, Supplying, Laying And Installation Of Hdpe Pipe Of Pe-80 Grade, Pn-6, 200 Mm Diameter By Horizontal Directional Drilling (Hdd) / Trenchless Method For Accommodating 11 Kv, 3×185 Sq.Mm Xlpe Insulated, Armoured Cable, Including Execution Of Road Crossing Or Similar Crossings Wherever Required, Complete With Pilot Drilling, Reaming And Pullback Operations, Proper Jointing Of Hdpe Pipe (Butt Fusion/Electrofusion), All Labour, Tools & Plants, Machinery, Drilling Fluid, Safety Arrangements, Formation Of Entry And Exit Pits And Site Restoration; The Contractor Shall Be Fully Responsible For Obtaining Necessary Permissions, Protection Of Existing Utilities And Resolution Of All Right Of Way (Row/Raw) Issues During Execution. 60 Earthing Of 125 Nos 11 Kv La Sets On DtS Supports With Ms Earth Rod Of (20X2500)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of 25Mm X 3Mm Gi Strip & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts And Required 25Mm X 3Mm Gi Strip As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. 61 Providing The Material And Execution Gi Pipe Earthing With 40 Mm Dia B Class Gi Pipe 80 Feet Boar To Water Level For Proper Earthing ( Earthing Resistance Less Than Or Equal To 1 Omh ) At 33/11 Kv Substation With The Help Of 50Mm X 6Mm Gi Strip Duly Welding To Dt Transformer Other Equipment. With Earthing Mess Lug, Nut And Bolt. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor. All Labour, T&P Will Be Provided By Contractor In All Respects. 62 Providing, Supplying And Fixing Of Copper Bus Bar Of Size 80 Mm × 10 Mm Suitable For 11 Kv Vcb Panel, Including Cutting, Drilling, Bending, Proper Alignment, Insulation Clearance, And Secure Fastening With All Required Nuts, Bolts, Washers And Supports, Ensuring Proper Electrical And Mechanical Connections, Complete In All Respects; The Work Shall Include All Labour, T&P Will Be Provided By Contractor In All Respects. 63 Grouting Of Following Pcc Pole 8.5 Mtr. Long Supports In Cc 1:3:6 (Cement, Sand & 40Mm Brick Ballast) Grouting Will Be Done In The Block Of Size (450X450)Mm X1/6Th Of Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With Cc 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. 64 Providing And Fixing Of Pg Clamps (Parallel Groove Clamps) Of Suitable Sizes For Making Conductor-To-Conductor Connections, Including Dog Conductor To Dog Conductor And Panther Conductor To Panther Conductor Joints, Complete With All Necessary Nuts, Bolts And Accessories, Ensuring Proper Electrical And Mechanical Continuity, As Per Relevant Standards And Directions Of Site Incharge All Labour, T&P Will Be Provided By Contractor In All Respects. 65 Providing And Fixing 11 Kv Relay, With (E/F & O/C) Of C&S, Ashide, Abb Make With 1&5 Amp Port Suitable For 11 Kv Feeder Pannel As Per Respo/Norms And As Per Direction Of Site Incharge. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor With All Labour, T&P In All Respects. 66 Providing And Fixing Of Wti Meter Isi Mark For 33/11 Kv Power Transformer Work Including Making Connection Proper Opration Of Wti , As Per Respo/Norms And As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. 67 Providing And Fixing Of Oti Meter Isi Mark For 33/11 Kv Power Transformer Work Including Making Connection Proper Opration Of Wti, As Per Respo/Norms And As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. 68 Providing And Fixing Of 11 Kv Lighting Arrester With 11/0.4 Kv Dt And Make Connection (25Mm X 3Mm Gi Strip Will Uniform Fixing Of Lighting Arrester With Transformer) 69 Providing And Fixing Of Vaccume Interupter In 11 Kv Pannel, As Per Direction Of Site Incharge. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor All Labour, T&P Will Be Provided By Contractor In All Respects. 70 Providing And Fixing 33 Kv Ct Stracture As Per Respo/Norms And As Per Direction Of Site Inchagre Work Includs Grouting Stracture And Making Plinth As Per Norms All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor All Labour, T&P Will Be Provided By Contractor In All Respects.
|