Fluorescent And Polarizing Microscopes – Confocal Microscope System Supply. Confocal Microscope System - 1 Piece With The Following Technical Specifications Or Minimum Functional Requirements: Confocal Microscope: -Motorized Inverted Microscope Stand, -The Movement On The Z Axis Of The Microscope Must Be Motorized With A Maximum Focusing Step Of 10Nm,- Interfaces Available On The Stand For Adding Various Accessories: 4Xcan, Usb-C And Tcp/Ip, Plug For Controlling An External Shutter, -Motorized Turret Head For At Least 6 Objectives And Automatic Objective Recognition System Mounted; - Side Ports With 3 Positions On The Left And Right And In The Eyepieces: - Photo Tube Ergonomically Inclined At A Maximum Of 45 Degrees, - Motorized Table That Ensures A Travel Stroke Of At Least 130X100mm, Speed Min. 50Mm/Sec, Resolution 0.1 Μm Or Better, Minimum Surface 325X 140Mm, - Support For Various Plates With A Surface Between 124..127 X 83..86Mm, - Support For Slides, - Support For Petri Dishes With Diameters: 47-56 Mm And 30...40Mm, - Support For Cameras: Ibidi, Nunc Lab-Tek, - Protective Cover, - Transmitted Led Lighting, Color Temperature 5600-5700K, Color Rendering Index Minimum 90, - Screen Type Tft Touch Screen, For The Presentation And Command Of The Motorized Elements Of The Stand, - Objective 5X Magnification, Minimum Numerical Aperture 0.16, Minimum Working Distance 18.5Mm, Automatic Recognition System, - 10X Apochromatic Objective, Minimum Numerical Aperture 0.45, Minimum Working Distance 2.1 Mm, Automatic Recognition System, - 20X Apochromatic Objective, Minimum Numerical Aperture 0.8, Minimum Working Distance 0.55Mm, Automatic Recognition System, - Lens Apochromat 63X With Minimum Aperture Of 1.4 With Immersion In Oil, With Minimum Working Distance Of 0.19Mm, Automatic Recognition System, - Motorized Condenser, With Minimum Numerical Aperture Of 0.55, Minimum Working Distance Of 26Mm, - Automatic System For Automatic Detection Of The Preparation, • Acquisition Of An Overall Image, • Automatic Identification Of The Type Of Sample Support, • Detection Of Areas With Sample Preparation, • Focus Adjustment For Each Region Of Interest:-10X Eyepieces, With A Minimum Wide Field Of 23 Mm, Focusable With Rubber Protection,-Motorized Support For Fixing At Least 6 Fluorescence Filters With Automatic Filter Recognition System Installed;-Led Fluorescence Source In Full Configuration, With Variable Intensity, With At Least The Following Excitation Sources: 385Nm,423Nm, 469Nm,555Nm,591Nm,631Nm And 735Nm,-Fluorescence Source To Allow Simultaneous Or Individual Visualization Of The Following Fluorochromes:-Dapi, Fitc, Tritc And Cy5,-Dapi, Gfp Mcherry Monochrome Digital Camera:-Minimum Number Of Pixels: 2464X2056=5.07 Mpixel,-Pixel Size: 3.45Μmx3.45Μm,-Sensor Size: Minimum 8.5Mmx7.1Mm,-Speed: Minimum 36 Frames/Sec At A Resolution Of 2464X2056 Pixels,-Digitization: 12 Bit/Pixel,-Usb 3.0 Interface,-Camera Chip With Cooling To Reduce Image Noise,-Exposure Time: 1Ms To 4S,-Spectral Range Of Detection: 350..1000Nm,-Optical Interface: C Mount,-Supported Operating System: Win 10, 11 Or
|